SZ3000-73-2A-L6 SZ3000-56-1A VVQ1000-51A-C6 VVQ1000-51A-C8 SZ3000-74-1A-L6 SZ3000-74-1A-L8 SZ3000-74-2A-L6 SZ3000-74-2A-L8 4(A), 2(B) port 1(P), 3(R) port Other Tube Brands Caution 1.
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
(x} = 3/8" NPTF (NVs 3135 only) Cv 2.58 04 = 1/2' NPIF (N\'s 3135, 3145 only) 3135 = Cv 2.58; 3145 = Cv 4.17 06 = 3/4'NPTF (tlVS 3145 only) Cv 4.50 4 9 = REPLACEMENT SOLENOID ASSEMBLIES tws 3t5 & 3135 NVS 3145 11ry50F8 a/@l+ 110/120V 50/60 t 11ry50H2 2A-03 22u@Hz 2A-05 24VAC 5d60Hz 4ry60Flz 24qfitNrla 40ry6oHz A653 INVS3125) 12 VDC, 2a VDC 24VOC A652 (NVS3125) A0&53 24VOC 408-52 l2VOC a0&
B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1. How to order Indicate option symbol "-K" in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet. SOL.
/60Hz 5 6 V S R 1 2 Series Without light/surge voltage suppressor Nil SY3000 SY5000 3 5 With surge voltage suppressor S With light/surge voltage suppressor Z A, B port size A, B port size 200VAC 50/60Hz 110VAC 50/60Hz [115VAC 50/60Hz] With surge voltage suppressor (non-polar type) Applicable series Applicable series Port size Port size Symbol Symbol R 3 02 C8 C10 Rc(PT) 1/4 8 One-touch fitting
Valve stations R Port NPTF -02 2 stations Single solenoid coil is located on the opposite side of the A, B port.
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
P-E01-2A The multi-pin connectors replace the wiring inside the manifold blocks and provides flexibility in modifying the manifold configuration.
Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1. How to order Indicate option symbol "-K" in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet. SOL.
override Rated voltage Nil Push type 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz B Locking type (Slotted) C Locking type (Manual) 110 to 120 VAC, 50/60 Hz 4 Surge voltage suppressor Option 220 VAC, 50/60 Hz Indicator light 24 VDC 12 VDC 5 6 Light/Surge voltage suppressor E EZ Nil None 7 240 VAC, 50/60 Hz With light/surge voltage suppressor (Type E, T, D, or Y only) 9 Other Z Option S With
0.5 MPa Load rate: 50% Stroke 60 mm Series MB, CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Vertical, upward actuation Horizontal actuation 10-SYJ7143-02 Cylinder is in extending.
/60Hz) 2 200V AC (50/60Hz) 3 110V AC (50/60Hz) 4 220V AC (50/60Hz) 5 24V DC 6 12V DC 7 240V AC (50/60Hz) 9 Other Option Body size Port size Electrical entry (Only solenoid) Port size Rc(PT) P, A port R port Body size Electrical entry Port 01 1 02 VEX 1 8 1 8 G Grommet (300mm lead wire) 1 4 1 4 H Gromet (600mm lead wire) 02 3 03 1 4 1 4 D DIN connector 3 8 3 8 DO DIN connector (Without connector
VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil assembly with terminal part no. Coil no.
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
Pressure 0.5 MPa Load rate: 50% Stroke 60 mm Series MB/CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series MB/CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ7140-02 Cylinder is in extending.
B M5 x 0.8 M4 xO.7 5-30 '11 20 32 2 6 7 8 1 7 2A 1 6 . 5 1 M5 x 0-8 N45 x 0.8 5-50 1 4 26 40 3 8 I 8 20 1 9 21 M5 x 0.8 N.45 x 0.8 5-50 t l ) . 5 1 8 32 50 4 1 0 1 0 1 0 20 22 43.5 22 1/8 (PT) 1i8 (PT) 5-50 1 9 5 22 40 5 1 l 1 2 24 29 5 1 . 5 22 23 i il : lModel I l ] H : H A L J KI L Mt\4 NA NB oP Q ] . , R i l : : S I sl L', . l Y r l lrye f Kqgq'l 26 5 1 4 M4 xO.7 5 M5 x 0.8 6 1 8 4.5
B M5 x 0.8 M4 xO.7 5-30 '11 20 32 2 6 7 8 1 7 2A 1 6 . 5 1 9 M5 x 0-8 N45 x 0.8 5-50 1 4 26 40 3 8 I 8 20 1 9 21.5 M5 x 0.8 N.45 x 0.8 5-50 t l ) . 5 1 8 32 50 4 1 0 1 0 1 0 20 22 43.5 22 1/8 (PT) 1i8 (PT) 5-50 1 9 5 22 40 5 1 l 1 2 24 29 5 1 . 5 22 23 i il : lModel I l ] H : H A L J KI L Mt\4 NA NB oP Q ] . , R i l : : S I sl L', . l Y r l lrye f Kqgq'l 26 5 1 4 M4 xO.7 5 M5 x 0.8 6 1 8
Nil Applicable blanking plate assembly SYJ300-10-2A 02 2 stations Pilot valve is on the A port side.