SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-S46-17-M5T"

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 4 Port/Base Mounted Common SUP Common EXH, Stations: 17 Stations, A B Port Size: Base Mounted M5X0.8, P R Port Thread: NPTF

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 5 Port/Base Mounted Common SUP Common EXH, Stations: 17 Stations, A B Port Size: Base Mounted M5X0.8, P R Port Thread: NPTF

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 5 Port/Base Mounted Common SUP Individual EXH, Stations: 17 Stations, A B Port Size: Base Mounted M5X0.8, P R Port Thread: NPTF

-20SS5YJ3-21PSS5YJ3-21SA 3SYJ3000-33-1 R SYJ312SYJ312M SYJ300 3 SYJ322SYJ322M SYJ300 3 SS5YJ3-31-S31SS5YJ3-32-S32SS5YJ3-32SA SS5YJ3-46-S46SS5YJ3-32P SYJ3000-33-1 SYJ3000-33-1 3 R R 3AB SYJ314SYJ314M SYJ324SYJ324M SS5YJ3-41-S41 3SYJ3000-33-1 R 3AB SYJ314SYJ314M SYJ324 SYJ324M SS5YJ3-20 SS5YJ3-41 B3 A B3 A M1.7 : 0.12N.m 17 No.SYJ300-OMU0003 Assy SYJ32(R)(-Q)) (SYJ34(R)(-Q)) SYJ300

(Including bracket, screw) DAuto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 -X Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.

Most sensitive position 10-20-16 17 Reed Switch Rail Mounting Style D-A73C/D-A80C For details about certified products conforming to international standards, visit us at www.smcworld.com.

Most sensitive position 6-16-17 18 Reed Switch Tie-rod Mounting Style D-A5/D-A6 For details about certified products conforming to international standards, visit us at www.smcworld.com.

D-A90V, D-A93V, D-A96V M2.5 x 4l Slotted set screw Indicator light D-A90V without indicator light 8-30-16 Most sensitive position 17 Reed Switch Direct Mounting Style D-Z73/D-Z76/D-Z80 For details about certified products conforming to international standards, visit us at www.smcworld.com.

Most sensitive position 9-15-17 18 Reed Switch Tie-rod Mounting Style D-A5/D-A6 For details about certified products conforming to international standards, visit us at www.smcworld.com.

D-A90V, D-A93V, D-A96V M2.5 x 4l Slotted set screw Indicator light D-A90V without indicator light 8-30-16 Most sensitive position 17 Reed Switch Direct Mounting Style D-Z73/D-Z76/D-Z80 For details about certified products conforming to international standards, visit us at www.smcworld.com.

D-A90V, D-A93V, D-A96V M2.5 x 4l Slotted set screw Indicator light D-A90V without indicator light 8-30-16 Most sensitive position 17 Reed Switch Direct Mounting Style D-Z73/D-Z76/D-Z80 For details about certified products conforming to international standards, visit us at www.smcworld.com.

NT-02 NT-03 NT-04 13 15.0 12.5 M8 x 1.25 5 17 19.6 16.5 6 M10 x 1.25 22 25.4 21.0 8 M14 x 1.5 2 x LD Mounting Nut Applicable pin part no. Part no.

) 18.5 (17) 20 20 12.5 12.5 22.5 22.5 2026.5 (25) 20.5 (19) 28 22 20.5 14.5 24.5 30.5 34 (32.5) 23 (21.5) 36 24.5 28 17 27 38 Data 34 (32.5) 30 (28.5) 36 31.5 28 24 34 38 44 (42.5) 35 (33.5) 46 6.5 38 29 39 48 As for auto switch mounting dimensions, auto switch mounting method and its operating range, those are the same as basic type.

17 17 2.5H9 +0.025 0 depth 2.5 3 3.4 64.3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4-M3 x 0.5 thread depth 7 Mounting thread 32 72 2-M3 x 0.5 thread depth 4 Mounting thread 15.8 58 5.9 E 11 11 14 19 E 0 -0.1 4-2.6 through (Mounting hole) M3 x 0.5 17 18 0.8

Individual -X Technical data 571 Series CQS Dimensions: 12 to 25/Single Acting, Spring Return Foot style: CQSL/CDQSL Special cap bolt L B + Stroke Foot Style Without auto switch A With auto switch A Stroke range (mm) Bore size (mm) 12 16 20 25 L L1 LD LG LH LT LX LY LZ X Y SMC B 17 17 LS 5 5 7.5 7.5 B 22 22 LS 10 10 LY LH SMC 13.5 24 4.5 4.5 6.6 6.6 2.8 2.8 4 4 17 19 24 26 2 2 3.2 3.2 34

MM NA 20, 25 2-Eh8 D Standard port Relief port 45 AL 1.5 A 1.5 K F N N H S + Stroke F ZZ + Stroke 32, 40 (mm) H2 22 17 17 13 B1 41 32 32 26 B2 H H1 11 8 8 8 13 F Bore size AL K MM NA NN G ZZ S P N I E D A 0 50 45 45 41 6 6 5 8 8 8 14 12 10 8 20-0.033 21 19.5 19.5 15.5 154 122 120 116 1/8 24 22 22 18 40 32 25 20 42.5 34.5 30 24 21.5 15 15 15 88 64 62 62 7 5.5 5.5 5 46.5 37.5 33.5 28 M26 x

10 11 8 8 8 8 10 12 9 12 17 20 22 29 11 12 13 16 20 24 20.5 22 28 33 43.5 51.5 15 10 10 11.5 12.5 13 12.5 18 21 26 29 33 42 10 11 14 16 20 24 17 18 25 30 38 48 5 6 8 10 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 16.5 16.5 Note) 19 21.5 23 Without auto switch With auto switch Bore size (mm) 6 10 16 20 25 32 DNN P Q QA R T Y S 33 36 30 36 40 42 Z 51 57 56 65 73 84 S 33 36 40

Port Cushion valve Bore size (mm) Double clevis type/(D) Z ZZ CDH10 32 40 50, 63 80, 100 160 164 190 238 170.5 175 205 261 Double clevis type U Bore size (mm) Stroke range CDH10 CX +0.3 +0.1 CZ L RR U Z ZZ L Z + Stroke RR CX 32 40 50 63 80 100 to 500 to 500 to 600 to 600 to 750 to 750 23 23 30 30 42 42 10.5 11 15 15 23 23 13 13 17 17 26 26 28 28 40 40 60 60 154 158 182 182 228 228 164.5

Auto switches / Proper mounting position at stroke end detection D-C73 D-H7A1 / H7B Auto switch Auto switch 16 16 6Hs A 29 B 6Hs A 26 B (mm) Bore size D-C73 D-H7A1/H7B A B Hs A B Hs 6 10 16 3 3 20.5 2 2 20.5 2 2 15 1 1 15 2.5 2.5 17 1.5 1.5 17 Note) The above-mentioned value is a guide for auto switch mounting position for stroke enddetection.

17 13 B1 6 5.5 5.5 5 K 44 35.5 29 24 NA 9 7 7 7 RA 26 20 16.5 14 C 130 121 119 114 ZZ 14 10 8 6 KA 78 79 77 77 S 16 12 10 8 D 25 18 14 12 E 2 2 2 2 F 40 32 25 20 30 22 22 18 23 0<23> 0 0 10 0 0 0 M5 x 0.8 depth 7.5 M5 x 0.8 depth 8 M14 x 1.5 M6 x 1 depth 12 12 12 1/4 1/4 3/8 1/2 58 58 27 27 32 41 14<12> 14<12> 10 10 10 10 23 20 20 20 11 11 58 72 20<17> 20<17> 16 16 71 71 13 16 89 110 7 7