Grommet (G): VQZ2 2(R)G -N3T, N7T, M5T N3T: One-touch fittings for 5/32" N7T: One-touch fittings for 1/4" 23.5 Mounting holes 70 300 M5T: M5 thread 19.3 (Lead wire length) R2.7 22.5 29.5 A 11 15 SMC 27 34 2 8 Cover diameter 1.4 Cross sectional area 0.2mm2 3.5 20.5 34 Manual override M3 x 0.5 External pilot port 22.7 Mounting holes (Only external pilot port type(R)) 25 10 (N3T, N7T) (M5T)
Note Auto switch model Switch mounting screw M2.5 x 10 L D-E7A.80A BMY1-025 25 32 40 Switch mounting nut D-M5 D-M5W D-M5T Switch mounting screw M2.5 x 12 L BMY2-025 Switch mounting nut 1116 ML1C Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 3 to 12 for Actuator and Auto Switch Precautions.
Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon 12 POLYURETHANE TUBING SERIES TU, TIUB H O W T O O R D E R P O LY U R E T H A N E T U B I N G S E R I E S TU & TIUB Soft and very flexible tubing TU 20 M O D E L C O L O R TU .mm TIUB ...inch B Black BU Blue G Green R Red W White Y Yellow C Transparent YR Orange T U B E T Y P E Imperial 01 05 07 11 13
R 3AB SYJ314SYJ314M SYJ324SYJ324M SS5YJ3-41-S41 3SYJ3000-33-1 R 3AB SYJ314SYJ314M SYJ324 SYJ324M SS5YJ3-20 SS5YJ3-41 B3 A B3 A M1.7 : 0.12N.m 17 No.SYJ300-OMU0003 Assy SYJ32(R)(-Q)) (SYJ34(R)(-Q)) SYJ300-10-7A(-Q) SY100-33-3 (M1.717) SY100-33-3 M1.717 CE -Q SYJ300-5-6 SYJ300-5-12 M1.7-0.12N.m 18 No.SYJ300-OMU0003 SYJ300 1 SYJ500-9-1(-Q) 1 7 2 8 V111(T)3 Assy SYJ5000-13-3A 4 5
Back port (Refer to P . 8-12-3.)
1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Inrush 1.3 VA (12 mA), Holding 1.3 VA (12 mA) 110 VAC VQD Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 200 VAC Inrush 2.6 VA (12 mA), Holding 2.6 VA (12 mA) 220 VAC Note 1) Note 2) Use dry air to prevent condensation when operating at low temperatures.
Description Material Quantity VVQ1000-80A-1 VVQ1000-80A-2 VVQ1000-80A-3 VVQ1000-80A-4 12 12 12 12 HNBR HNBR Carbon steel Stainless steel Gasket Packing Clamp screw Clip o !0 !1 !2 Pilot valve assembly V112 Note) A set of parts containing 12 pcs. each is enclosed.
2 Gasket Seal Clamp screw Clip HNBR HNBR Carbon steel Stainless steel 12 12 12 12 Pilot valve assembly V112 1021Enclosure Note) A set of parts containing 12 pcs. each is enclosed.
2 Gasket Seal Clamp screw Clip HNBR HNBR Carbon steel Stainless steel 12 12 12 12 Pilot valve assembly V112 1021Enclosure Note) A set of parts containing 12 pcs. each is enclosed.
2 Gasket Seal Clamp screw Clip HNBR HNBR Carbon steel Stainless steel 12 12 12 12 Pilot valve assembly V112 A Function Coil voltage Note) A set of parts containing 12 pcs. each is enclosed. 1 2 3 4 5 6 Symbol Specifications DC AC 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC (0.4 W) Note 1) Nil Standard (0.95 W) High-speed response type B (0.95
(Including bracket, screw) RS Q G Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 RS H A Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) CA2 Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 CS1 Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) CLS Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 CLQ Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) -X Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 20Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) -X Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 20Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) -X Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 20Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) DAuto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 -X Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com