Tube size AQ 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F TMH-01J TMH-03J AK TMH-05 TMH-07 TMH-09 ASS TMH-11 TMH-13 Dimensions Model D2 D1 H1 H2 H3 H4 H5 L1 L2 L3 Symbol Metric Inch TMH-23J TMH-04J 1/8J 1/32J 3/16 6 1/4 8 5/16 10 3/8 12 1/2 8.4 9.3 11.7 11.6 13.1 13.5 15.5 18.5 18.8 21.2 22 TMH-01J TMH-03J TMH-05 3.3 4.5
For double solenoid For 3 position type: For 4 position type SX100-40-4DNegative common specifications Electric circuit diagram (With positive common and light/surge voltage suppressor) For single solenoid: SX100-41-4SFor double solenoid For 3 position type: For 4 position type SX100-41-4D[SOL.b] () Coil How to Order
18.5 29.5 55.3 23 9.8 49.3 R 1/4 1.2 19 21.8 AS321F-02-10SD AS321F-N02-07SD 1/4" 13.2 27.8 39.3 17 10 18.5 43.3 21 31.8 AS321F-02-12SD AS321F-N02-09SD NPT 1/4 19 23 9.8 21.8 55.3 1.2 49.3 12 5/16" 15.2 29.5 41 18.5 20.9 44.3 22 32.8 AS321F-03-06SD AS321F-N02-11SD 6 17.9 31.8 43.3 21 3/8" 12.8 39.3 17 27.8 AS321F-03-08SD AS321F-N03-07SD 8 15.2 41 18.5 29.5 1/4" 13.2 27.8 39.3 17 53.7 23 9.8
12 x 17 Miniature pneumatic indicator VR3200 Pneumatic-electric relay Dimensions VR3200: 17 x 49 x 71 VR3201: 25 x 86 x 89 VR3201 VR4151 Relay valve 7 5 Metal Spool Dimensions Side piping: 30 x 53 x 91 Bottom piping: 30 x 48 x 91 VR4152 INDEX Mechanical Valves Page Series VM1000 P . 5-6-8 Series VM100 P . 5-6-12 Series VM200 P . 5-6-20 Series VM400 P . 5-6-26 Series VZM500 P . 5-6-41
M1 M2 Weight (g) ASV310F-N01-07 ASV310F-N01-09 ASV310F-N02-07 ASV310F-N02-09 ASV410F-N01-09 ASV410F-N01-11 ASV410F-N02-09 ASV410F-N02-11 ASV410F-N03-09 ASV410F-N03-11 ASV510F-N02-11 ASV510F-N02-13 ASV510F-N03-11 ASV510F-N03-13 ASV510F-N04-11 ASV510F-N04-13 73 73.8 73 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.9 90.2 91.9 90.2 91.9 17.2 19.3 17.2 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3 26.5
Section code Note) Mounting SUP/EXH block assembly When the location is non-standard, indicate both SUP/EXH block assembly part no., quantity and manifold part number. 13-14-41 41 Date issued: Photo copying this page is recommended.
KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-01 KQ2P-03 KQ2P-07 KQ2P-09 3.2 4 6 8 16 16 18 20.5 31.5 32 35 39 1/8" 5/32" 1/4" 5/16" 16 16 18 20.5 31.5 32 35 39 3.2 6 8 10 5 6 8.5 10 Port plug VVQ0-58A The plug is used to block the cylinder port.
COM. 41 Red Red COM.
KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-01 KQ2P-03 KQ2P-07 KQ2P-09 3.2 4 6 8 16 16 18 20.5 31.5 32 35 39 1/8" 5/32" 1/4" 5/16" 16 16 18 20.5 31.5 32 35 39 3.2 6 8 10 5 6 8.5 10 Port plug VVQ0-58A The plug is used to block the cylinder port.
L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.
EDS Enable (SC_MonOp) 1 1 Disable Auto (SC_RstOp) 2 Manual Enable 3 (OC_Mon) 6 Disable Clear OFF 2 6 Hold 4 (Fault_MD) ForceON ON Clear OFF 2 3 6 Hold 5 (Idle_MD) ForceON ON Enable Val165000 5 ON ON/OFF (Counter) 6 6 4 Disable 1() 2Hold/Clear Handheld 3PLC 41 5x1000 6DeviceNet TM(DeviceNet TM2) -46No.EX-OMN0029CN-D No. (H.T.) H.T.
IIIB OA DB IOL lou DC OX iDE .1 00 DS OH Z ODHIl ": ~ 46 , 31 1 21 18 5 3a , 2' 1 51 l a.5 6.6 If 7 32 1184 lO ' ;~ 52 35 ,24 I 22 15.5 41 21 i 54 16.5 6.6 11 9 ' 36 l a, J:!'
KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-01 KQ2P-03 KQ2P-07 KQ2P-09 3.2 4 6 8 16 16 18 20.5 31.5 32 35 39 1/8" 5/32" 1/4" 5/16" 16 16 18 20.5 31.5 32 35 39 3.2 6 8 10 5 6 8.5 10 Port plug VVQ0-58A The plug is used to block the cylinder port.
(Example) SS3YJA3-41-03-M3 . 1 set SYJA314. 1 set SYJA324. 1 set SYJ300-10-2A . 1 set The asterisk denotes the symbol for assembly.
(A) 2 (A) 2 SS3YJA5 Specify the same manifold part number as SS3YJ5. (SYJA500) SS3YJA7 Specify the same manifold part number as SS3YJ7. (SYJA700) 1 (P) 3 (R) 1 (P) 3 (R) Specify the part numbers for the valve(s), blank plate assembly and manifold base. N.C. N.O.
29.5 18.5 55.3 23 9.8 49.3 R 1/4 1.2 19 21.8 AS321F-02-10SD AS321F-N02-07SD 1/4" 13.2 27.8 39.3 17 10 18.5 43.3 21 31.8 AS321F-02-12SD AS321F-N02-09SD NPT 1/4 19 23 9.8 21.8 55.3 1.2 49.3 5/16" 15.2 29.5 41 18.5 12 20.9 44.3 32.8 22 AS321F-03-06SD AS321F-N02-11SD 17.9 31.8 43.3 21 6 3/8" 12.8 39.3 27.8 17 AS321F-03-08SD AS321F-N03-07SD 8 15.2 41 29.5 18.5 1/4" 13.2 27.8 39.3 17 53.7 23 9.8
double solenoid For 3 position type For 4 position type [SOL.B] () Coil : SX100-41-4DCOM (+) How to Order
No.PF-OMJ0005CN-I () // PFM7## 2 10 13 14 14 16 17 20 22 22 F0 23 F1 OUT1 24 F2 OUT2 27 F3 28 F4 29 F5 30 F6 31 F7 32 F8 35 F9 36 F10 38 F11 39 F12 40 F13 41 F98 42 F99 44 45 49 50 53 54 54 57 59 73 -1No.PF-OMJ0005CN-I (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules
Operation at occurrence of circulating fluid discharge pressure rise alarm RUN HIPRS ALARM(Alternately displayed) HRR Series 5.5 Advanced setting mode 5-33 HRX-OM-W002 Chapter 5 Display and Setting of Various Functions The user can decide the chiller behaviour if alarm "AL 09: circulating fluid discharge pressure rise" occurs.
Piping: 41 (Base Mounted), Stations: 9 Stations, A, B Port: 01N (NPT1/8)