Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: M9BW, Lead Wire Length

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 40mm

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 50mm, Body Option: M (Rod End Male Thread)

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 75mm, Body Option: M (Rod End Male Thread)

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 40mm, Body Option: M (Rod End Male Thread)

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 100mm

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 75mm

Magnet: Built-in Magnet, Mounting: Double Clevis, Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 40mm, Body Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Double Clevis, Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 100mm, Body Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Double Clevis, Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 75mm, Body Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

The TRB series is available in a variety of colors. 100m roll is available for all color types. FR double layer polyurethane tubing, Flame resistant, Equivalent to UL-94 standard V-0, 20m bundle and 100m reels available, Several color options available, TUBING, CONNECTORS, TR FLAME RESIST TUBING, LX, TR 12MM, 32.64479 lb, ModelInner tubing O.D. (mm)Inner tubing I.D.

The TRB series is available in a variety of colors. 100m roll is available for all color types. Double layer nylon tubing, Flame resistant, Equivalent to UL-94 standard V-0, Suitable for air and water piping, TUBING,FIRE RESIST,WHITE, 100M, CONNECTORS, TR FLAME RESIST TUBING, JX, TR 10MM, 21.12414 lb

(1) Do not drop, hit nor apply excess impact(100m/s2 or more). Even if the appearance of electrostatic sensor is not damaged, internal parts will be damaged resulting in malfunction. (2) Dont handle with wet hand to avoid electric shock and accident. (3) Wait for 10min. or longer after applying the power.