Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Max. speed (mm/s) Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 6 (7) (8) (9) 10 15 Selection graph 20 (10) (11) (12) (13) (14) (15) (17) (16) 25 32 The maximum speeds for 10 to 32 are
resistance D-A93, D-A93V, D-A96, D-A96V (with indicator light) D-A93, D-A93V D-A96, D-A96V Switch model Applicable load Relay, PLC IC circuit Caution Load voltage 24 VDC 4 to 8 VDC 100 VAC Operating Precautions Load current range and Maximum load current 20 mA 5 to 40 mA 5 to 20 mA Note 2) Fix the switch with appropriate screw installed on the switch body.
Note 3) Load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 10-20-7 for contact protection box.) Most sensitive position ( ): dimensions for D-A93.
type) 300 100 Displacement m Displacement m 250 90 200 80 50 130 150 MSQA30 (High precision type) 70 60 0 0 10 20 30 40 50 60 70 12 10 8 6 4 2 Load N Load N MSQ50 MSQB7A MSQB50 (Basic type) 100 200 Displacement m Displacement m 90 150 80 120 50 MSQA50 (High precision type) 70 60 0 0 20 40 60 80 100 120 6 8 10 14 12 2 4 Load N Load N 5 Rotary Table Air Consumption Air consumption is the volume
Note 3) Load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 9-15-7 for contact protection box.) Most sensitive position ( ): dimensions for D-A93.
(II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-M9P(V), A93(V) and A90(V), please refer to page 16, 19. (Note: Reed auto switches for 100 VAC and 100 VDC are not within the specification.
Note 3) Load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 6-16-7 for contact protection box.) Most sensitive position ( ): dimensions for D-A93.
Note 3) Load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 8-30-7 for contact protection box.) Most sensitive position ( ): dimensions for D-A93.
Note 3) Load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 8-30-7 for contact protection box.) Most sensitive position ( ): dimensions for D-A93.
Note 3) Load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 8-30-7 for contact protection box.) Most sensitive position ( ): dimensions for D-A93.
voltage 100 VAC 24 VDC 4 to 8 VDC 1.
speed should be 100 to 200mm per second.
75, 100, 125, 150 175, 200 75, 100, 125, 150 175, 200, 250, 300 25 Standard Non-rotating Rod Anti-lateral Load Reed switch D-A90/A90V D-A93/A93V D-A96/A96V Series CQSW 12 16 5, 10, 15, 20 25, 30 7-4-20 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 Series CQS 12, 16 20, 25 12 16 20 25 5, 10 7-4-12 Solid state switch D-M9N/M9NV D-M9P/M9PV D-M9B/M9BV D-F9NW/F9NWV D-F9PW/F9PWV D-F9BW/F9BWV D-F9BAL
37.5 37.5 37.5 37.5 37.5 37.5 30 101 to 150 50 50 50 50 50 50 40 201 to 300 100 100 100 100 100 100 80 301 to 400 125 125 125 125 125 125 100 401 to 500 150 150 150 150 120 501 to 600 175 175 140 601 to 700 200 701 to 800 73 81 89 89 101 101 120 801 to 900 200 200 160 901 to 1000 180 1 to 50 86 94 102 102 114 114 130 51 to 100 98 106 114 114 126 126 140 101 to 150 111 119 127 127 139 139
Yes 5 V A93V A93 Grommet 12 V 100 V Relay PLC 24 V 2-wire IC circuit A90V A90 5 V,12 V 100 V or less M9NV M9N 3-wire (NPN) IC circuit 5 V 12 V M9PV M9P 3-wire (PNP) M9BV M9B 12 V 2-wire Relay PLC Yes Grommet 24 V F9NWV F9NW 3-wire (NPN) Diagnostic indication 2-color display IC circuit 5 V 12 V F9PWV F9PW 3-wire (PNP) F9BWV F9BW 2-wire 12 V . . .
L x 100 L 100 100 (mm) (mm) Cylinder model C D Mounting bolt size Cylinder model C D Mounting bolt size CQUB32-5 CQUB40-5 M5 x 65 L M5 x 65 L 65 65 -10 -10 x 70 L x 70 L 70 70 -15 -15 x 75 L x 75 L 75 75 -20 -20 x 80 L x 80 L 80 80 -25 -25 x 85 L x 85 L 85 85 -30 -30 x 90 L x 90 L 90 90 10.5 10.5 -35 -35 x 95 L x 95 L 95 95 -40 -40 x 100 L x 100 L 100 100 -45 -45 x 105 L x 105 L 105 105
Thus, it can be used in a Class 100 clean room.
Model XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 Rated voltage for heater 90 to 240 VAC Heater assembly quantity 1 1 1 1 H4 100C 100 V 200/40 200/50 400/100 600/150 Heater assembly quantity used Heater power W (Nominal value) Inrush/Power consumption (Option symbol, Operating voltage) 200 V 800/40 800/50 1600/100 2400/150 Heater assembly quantity 1 1 1 1 2 H5 120C 100 V 200/40 400/70 400/
V W Y 5 to 100 10 7 12 43 43.5 59 5 to 100 10 7 12 43 43.5 67 10 to 100 14 8 17 54 63 83 10 to 100 18 10.5 17 54 63 97 Note 1) The dimensions (A + stroke) and (B + stroke) for 5 mm stroke will be the same as those for 10 mm stroke.