SMC Corporation of America
Elite Part Number Search
Search Results "PSE541-N01-C2"

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: IM5H [M5 Female Thread Through Through Type (w/Mounting Hole)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: 01 [R 1/8(w/M5 Female)], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: M5 Female Thread Through Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: M3X0.5, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: N01 [NPT 1/8 (w/M5 Female Thread)]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Option: -

.: PSE541-M5-X2 The mounting plate is shipped together with the product but does not come assembled. Single unit part nos. p. 16 The piping methods for types with and without a mounting plate are shown in Table 2 below. The pressure sensor is shipped together with the product but does not come assembled. Table 1.

Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10

PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output.  The sensor construction optimizes space savings, for tight, constrained spaces.  PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa). 

PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output.  The sensor construction optimizes space savings, for tight, constrained spaces.  PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa). 

Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2% F.S., Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: L (IO-Link/Switch: 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm)

Without pressure sensor Note 1) P1 PSE541 P1A PSE541A P3 PSE543 P3A PSE543A Electrical entry B KQ2P-04 L L plug connector, with 0.3 m lead wire, with light/surge voltage suppressor Note 1) One-touch fittings are plugged when the pressure sensor is mounted. Note 2) This pressure switch detects pressure and converts the data into analog output.

PE Compact pressure sensor P PSE541-R04 Supply valve P Circuit diagram V -15No. TQ1230001-OM103-A 4.4. FANUC CRX Plug-in software The CRX plug-in software enables easy connection and mounting of the vacuum gripper to the robot. 1.

PE Compact P pressure sensor Supply valve PSE541-R04 P Circuit diagram V -15No. TQ1230001-OM101-D 4.4. URCap Installation and basic setting 1.

PE Compact P pressure sensor PSE541-R04 Supply valve P Circuit diagram V -15No. TQ1230001-OM102-B 4.4. TMComponent TMComponent is an independent software package for the robot applications and you need to import the software package to use in TMflow (robot software) directly. Here is the list of the SMC Vacuum Gripper TMComponents.

. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power

2 One-touch fitting 84 Double 94 2-position Single 82 Double 91 SY3l31-C2 3-position Closed center 98 Exhaust center Pressure center C2 2 One-touch fitting 3-position Closed center 95 Exhaust center Pressure center 4-position Dual 3-port valve 91 SY3l30-C2 2-position Single C3 3.2 One-touch fitting 87 Double 97 Metal seal SY3l31-C3 2-position Single 85 Double 94 3-position Closed center

(M12 plug) DIN rail clamping screw 60 (12) Plug-in Manifold Stacking Base 33.6 17.5 9.6 6.5 8.5 17.2 (7.5) 1(P) port C8: 8 (For A, B port metric size) N9: 5/16" (For A, B port inch size) 2n x C2, C3, C4, N1, N3 (4(A), 2(B) port) C2: 2 one-touch fitting C3: 3.2 one-touch fitting C4: 4 one-touch fitting N1: 1/8" one-touch fitting N3: 5/32" one-touch fitting Formula L1 = 8.5n + 31, L2 = 8.5n

C2: 2 (SMC) C4: 4 (SMC) 9.1 (C6) 10.3 (C2, C4) D D 3/5 B 2 E 3/5 B 2 B 2 B 2 E B 2 27 (C2, C4) 25.8 (C6) A 4 A 4 A 4 1 P P 1 4 A 4 A S (Pitch of C2, C4) P = 6.5 One-touch fitting [1(P), 3/5(E) port] Applicable tubing: 8 (SMC) (Pitch of C6) P = 9 * Refer to page 97 for dimensions of external pilot and built-in silencer. * Refer to pages 65 to 68, 79, and 80 for dimensions when L6, b, and

Signal 1 DC output 2 DC output 3 FG DC connector HED007-C2* (HED003-C2*, HED005-C2*) DDK D/MS3102A20-15S Connect the DC cable connector of Heat Exchanger. Pin No.