1) [EX123D-SUH1] Note 2) EX120-SSL1(-XP) Note 1) [EX123D-SSL1] Note 2) EX120-SSL2(-XP) Note 1) [EX123D-SSL2] Note 2) q EX120-SDN1 [EX124D-SDN1] Note 2) EX120-SCS1(-XP) Note 1) [EX124D-SCS1] Note 2) EX120-SCS2(-XP) Note 1) [EX124D-SCS2] Note 2) EX120-SMJ1(-XP) Note 1) [EX124D-SMJ1] Note 2) EX120-SCM1 EX120-SCM3 AXT100-1-P Note 3) U S U S U S U S w U S AXT100-1-J 20 Note 3) U S e r AXT100-
of 0.5 MPa) Type of actuation Without light/surge voltage suppressor S, Z type 26 or less 2 position single 18 or less 22 or less 2 position double 32 or less 38 or less 3 position 19 or less SX7000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) Type of actuation Without light/surge voltage suppressor S, Z type 38 or less 2 position single 27 or less
(4) C6 (6) M5 (M5 thread) kit C6 (6) N1 (1/8") N3 (5/32") N7 (1/4") N7 (1/4") P. 2-4-50 P. 2-4-54
block box N3 (for 5/32") N7 (for 1/4") N9 (for 5/16") C8 (for 8) C10 (for 10) C12 (for 12) N7 (for 1/4") N9 (for 5/16") N11 (for 3/8") Rc 1/4, Rc 1/8 (NPT, NPTF, G) S Kit: Serial transmission ( ) 4150 (9.15) T Kit 1 to 10 stations S Kit (without unit) Solenoid weight is not included.
SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
ND9200 ND7200 pointer marks on housing 45 45 ND9300 pointer marks on housing Fig. 4 Shaft coupling alternatives 7 ND90 71 en 13 Table 4 Piping and stroke times Actuator ND_2_ Supply 1/4" NPT Actuator 1/4" NPT ND_3_ Supply 1/4" NPT Actuator 1/4" NPT ND_6_ Supply 1/2" NPT Actuator 1/2" NPT B1C Stroke volume dm3 / in3 NPT Piping Open (s) Close (s) Piping Open (s) Close (s) Piping Open (s) Close
type (Slotted) N.C N.C 12 VDC 5 6 4 position dual 3 port valve (B) 2 position double (metal) 24 VDC Note) (A) 4 (B) 2 (A) 4 (B) 2 B Note) S kit is only available for 24 VDC.
Mounting hole Connector for Handheld Terminal End plate n 8 7 6 5 4 3 2 D side U side Station 1 3/4: 3/4" Female thread (Rc, G, NPT/NPTF) 3/4 [3(R) port] 1/2: 1/2" Female thread (Rc, G, NPT/NPTF) 1/2 [1(P) port] 56.6 30 15.7 101.2 8 95.5 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 77.3 11.5 72 43.5 42.7 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 20.6 21.5 11.5 1/8: 1/8" Female thread (Rc, G, NPT/NPTF) 1/8 (External
Ports 2, 4 size (metric) Ports 2, 4 size (inch) Ports 2, 4 Symbol C3 C4 C6 C4 C6 C8 C6 C8 C10 M Ports 2, 4 Symbol N1 N3 N7 N3 N7 N9 N7 N9 N11 M Ports 1, 3, 5 Applicable series Ports 1, 3, 5 Applicable series 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting
2.6 (For mounting) 2-2.6 (For mounting) 2-2.6 (For mounting) 20 20 20 2-2.6 (For mounting) (2.3) (2.3) 20 (2.3) 23 23 23 23 27 Refer to the page 91 for dimentions with connector cable. 28 Series SYJ5000 2 Position Double [ ]: AC G H Grommet (G), (H): SYJ5220-M5 Built-in one-touch fitting: SYJ5220G H C4, N3 C6, N7 G: Approx. 300 H: Approx. 600 (Lead wire length) 87.2 [91.6] 43 3.5 11 5 B
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve
A C1SF-6 AD17-6 C1SF-2 AD17-2 C2SF-C AD27-C C2SF-J C2SF-CJ C2SF-6 C2SF-6C AD27-6 AD27-6C C2SF-6J C2SF-6CJ C2SF-2 AD27-2 C2SF-2J C3SF-J C3SF-W C3SF-6 AD37-6 AD38-6 C3SF-6J C3SF-6W C3SF-2 AD37-2 AD38-2 C3SF-2J C3LF-8 AD37-8 AD38-8 C3LF-8J C4SF-J C4SF-W C4SF-6 AD47-6 AD48-6 C4SF-6J C4SF-6W C4SF-2 AD47-2 AD48-2 C4SF-2J C4LF-8 AD47-8 AD48-8 C4LF-8J Polycarbonate SMC K P C U O S
A 2 A 2 A 2 A 2 A (8) 1/8 [1(P), 3(R) port] 8 2 x 4.3 (For mounting) L5 6.5 One-touch fitting [2(A) port] Applicable tubing O.D.: 3.2, 1/8" 4, 5/32" 6, 1/4" 15 M5 x 0.8 [2(A) port] L4 L3 39.5 (Station 1) (Station n) C6: 44.1 N7: 47.9 (3.2) (For M5) 45.2 A A 20 (11) (7.5) 2 2 The dashed lines indicate the DIN rail mounting [-D].
](2) EX120-SFU1(-XP)(1) [EX123-SFU1](2) SX EX120-SDN1 [EX124-SDN1](2) EX120-SCS1(-XP)(1) [EX124-SCS1](2) VK EX120-SCS2(-XP)(1) [EX124-SCS2](2) EX120-SMJ1(-XP)(1) [EX124-SMJ1](2) AXT100-1-P (4) U S w e r U S U S VZ AXT100-1-F (4) U S AXT100-1-GU20 Note 1) Suffix XP for dust-proof SI unit.
Scale: 40% (5.5) (35) Grommet (G) (11) 27 24.5 Mounting holes n-N1, N3, N7, M5 N1: One-touch fittings for 1/8" N3: One-touch fittings for 5/32" N7: One-touch fittings for 1/4" M5: M5 thread (4.5) (7.5) 20 DIN rail clamp screw U side n Manual override 5 A 2 A 2 A 2 A 2 4 P=10.5 (L4) (L3) L1 L2 3 2 1 16.5 Stations 6.5 D side 2.3 2-M5 x 0.8 External pilot port 21.6 (Only external pilot port
Panel cut dimension 2 x 3.2 16.5 14.5 11 8.2 20 2 x 3.2 2 x 3.2 M3 thread hole 8.2 8.2 P U P S U H S H L O L C O K C K R V R S W V X S W T 19 T X 19 L2=50+T+X L2=50+T+X L1=50+R+V 14 L1=50+R+V 14 Pressure gauge (Accessory) 50 Pressure gauge (Accessory) 50 55 (at handle locked) 55 (at handle locked) IN OUT IN OUT 41.5 43.5 U Y 4 25 6 25 U Y 14 14 SMC SMC 2 x 3.2 2 x 3.2 42 42 IN side OUT side
pilot Flow Characteristics Flow characteristics Effective area (mm2) Port size 1 2 (P A) 2 3 (A R) Manifold C [dm3/(s bar)] 1(P), 3(R) Port 2(A) Port b Cv C [dm3/(s bar)] b Cv Body ported for internal pilot M3 x 0.5 0.9 Type SS3YJ3-20 SYJ32 M5 x 0.8 Type SS3YJ341 S41 SYJ34 M3 x 0.5 M5 x 0.8 1.5 0.17 0.36 0.3 0.17 Type SS3YJ3-42-M5 Base mounted for internal pilot M5 x 0.8 0.31 0.33 0.32
OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) Mitsubishi Electric Corp.: CC-LINK System 0 A B C D E F1 G H J1 J2 K Q R1 R2 V (2) Max. 16 stations Kit S Max. 8 P. 2-4-80 Max. 16 stations P. 2-4-82 C Connector kit 1 2 No. of terminals: 8, 1 row Applicable stations 1 to 8 Kit T Max. 8 Max. 16 No. of terminals: 16, 2 rows Max. 16 Applicable
(A) 2 (A) 2 2(A) 2(A) 3(R) (P)1 3(R) (P)1 i i 3 (R) 1 (P) 3 (R) 1 (P) u u Component Parts Replacement Parts Description Body Piston plate End cover Piston Spool valve assembly Spool spring No. No. 1 2 3 4 5 6 Description Note White White White Note Part no.