TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 CY3B6 CY3B10 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 CY3B50 CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d CYP C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2 30 37 47.3 d M6 x 1.0
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: S (Bracket for w/Flow Adjustment Valve)
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: S (Bracket for w/Flow Adjustment Valve
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment Valve
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment Valve
Cylinder air consumption 1.Determine the intersection point 1 of a 0.5 MPa working pressure with a stroke of 600 mm. 2.Extend the intersection point 1 upward to the intersection point 2 where a 50 mm is represented. 3.Extend the intersection point 2 rightward or leftward.
A 1-B 1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 1/8, 1/4 500 1.5 0 1,000 2,000
BB Attached from top with cap bolt Bolt size: MD LA A 4Counter bore depth CC XA FG 4-BA LF Body Switch rail FG X A FH XA High Precision Guide Type REAH HB Note 1) FF Note 1) HL D' FE Note 1) Floating block Section D-D' Max.
REAR25 20 21.5 40 28 72 5.6 M5 x 0.8 6.5 Rc 1/8 43 105 7 117 15 70 6 REAR32 26 24 50 35 79 7 M6 x 1 8.5 Rc 1/8 54 116 7 130 13 76 7 REAR40 34 26 60 40 93 7 M6 x 1 11 Rc 1/4 64 134 7 148 15 90 8 10-2-22 22 Sine Rodless Cylinder Basic Type Series REAR Proper Auto Switch Mounting Position (Detection at stroke end) A B RE A B REC C D CX 10 to 20 CY Auto switch model Bore size (mm) D-A9 A dimension
90 90 38 73 16.5 25.5 87 115 REAS25 Rc 1/8 40 70 100 90 42 73 16.5 25.5 0.5 1 97 115 REAS32 Rc 1/8 40 75 122 110 50 91 18.5 28.5 0.5 1 119 138 REAS40 Rc 1/4 65 105 145 120 64 99 20.5 35.5 1 1 142 155 PA dimensions are for split from center. 10-2-34 34 Sine Rodless Cylinder Slider Type: Slide Bearing Series REAS Proper Auto Switch Mounting Position (Detection at stroke end) RE A B B A
Select a bore size from Lo and Fn in Data (A). 20 10 10 Load Workpiece 5 Usable range Usable range 5 Fn Alignment deflection absorbing mechanism 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 Lo 7 8 9 7 8 9 10 11 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) 20 25 Selection Example 500 200 Given a load drive resisting force of Fn = 100 (N) and a distance from the
SGH(A)32-7020 SGH(A)42-7025 SGH(A)13-3010 SGH(A)23-3015 SGH(A)33-3020 SGH(A)43-3025 SGH(A)13-7010 SGH(A)23-7015 SGH(A)33-7020 SGH(A)43-7025 3/8 7.5 42 (1.8) 1.4 1.5 1/2 9.4 65 (2.7) 2.4 2.6 7 MPa 2-port 3/4 12.4 112 (4.7) 4.7 5.3 1 15.4 155 (6.5) 6.6 7.2 3/8 9.4 50 (2.1) 56 (2.3) 1.6 1.7 11 1/2 10.5 55 (2.3) 73 (3.0) 1.6 1.7 3 MPa 15 3/4 12 90 (3.8) 92 (3.8) 2.6 2.8 17 1 15.2 135
With cooperation from customers, we will Splash Proof Air Cylinders (E244) promote energy saving programs for pneumatic systems. 376 Coolant Valve Series SGC Made to Order Made to order specifications (For details, refer to page 389) How to Order External pilot solenoid 2 2 Y 1 A 05 1 T Z 10 A SGC Air operated 2 2 1 A 05 10 A SGCA q w e r t y u i o !0 !1 !2 !3 !4 !
I I I I ~'" " I ~, 0-1 ~~ l'L Cross-section A-A' Parts List No. Design.?liOh .
(Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety. etc. Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
Evaluate (1) and (2) as a (average speed), and (3) as (collision speed = 1.4 a). Calculate (1) (Wmax) from the graph of max. payload (W1, W2, W3) and calculate (2) and (3) (Mmax) from the maximum allowable moment graph (M1, M2, M3).
brake spring acting on a brake shoe 1 attached to brake holder, brake rails and holds brake plate between brake shoe 1 and brake shoe 2 fixed to slider side so that slider will stop.
Evaluate (1) and (2) as a (average speed), and (3) as (collision speed = 1.4 a). Calculate (1) (Wmax) from the graph of max. payload (W1, W2, W3) and calculate (2) and (3) (Mmax) from the maximum allowable moment graph (M1, M2, M3).
Brake force is generated by a brake spring acting on a brake shoe 1 attached to brake holder, brake rails and holds brake plate between brake shoe 1 and brake shoe 2 fixed to slider side so that slider will stop.
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)