Flow Range: 10~100 l/min, Thread: Rc, Port Size: 3/4, Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (1~5V)
Flow Range: 10~100 l/min, Thread: Rc, Port Size: 1", Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (1~5V)
Flow Range: 10~100 l/min, Thread: G thread, Port Size: 1", Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (1~5V)
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 3/4, Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (1~5V)
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (1~5V)
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (1~5V)
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Remote type sensor unit , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, HA, IFW/PFW 1 INCH PT VERSION, 2.47321 lb
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Remote type sensor unit , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, HX, IFW/PFW 1 INCH ALL OTHERS, 2.49292 lb
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
2% F.S. or less (15 to 35C based on 25C), ?3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: 2 (OUT1: Analog 4 to 20mA)