-XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) -XB7 Cold resistant cylinder (40 to 70C)*1 Mounting Brackets/Part No.
Bore size Standard Stroke 1.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 2, 2.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 3.25, 4 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How To Order NCA1 MOUNTING BORE STROKE N XB7 Ex: NCA1B 150-0400-XB7 Standard Auto-switch capable not available Low Temperature 21 Series NCA1 Medium Duty Air Cylinder Special Trunnion Location Specifications
(Or None in the Case of No Switch), Temperature Resistant: XB7 [Cold Resistant (-40 to 70°C)]
(Or None in the Case of No Switch), Temperature Resistant: XB7 [Cold Resistant (-40 to 70°C)]
(Or None in the Case of No Switch), Temperature Resistant: XB7 [Cold Resistant (-40 to 70°C)]
Mounting: A (Both Ends Tapped), Bore Size: 40mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Temperature Resistant Option: XB7 [Cold Resistant (-40 to 70°C)]
Mounting: Both Ends Tapped, Bore Size: 40mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Temperature Resistant Option: XB7 [Cold Resistant (-40 to 70°C)]
(Or None in the Case of No Switch), Temperature Resistant: XB7 [Cold Resistant (-40 to 70°C)]
(Or None in the Case of No Switch), Temperature Resistant: XB7 [Cold Resistant (-40 to 70°C)]
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -40~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -40~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -40~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -40~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Grease pack part number: GR-F-005 (5 g) XB7/Cold-resistant cylinder 6 10 16 CJP2B6D-XB7-PS CJP2B10D-XB7-PS CJP2B16D-XB7-PS Set of left nos. !0, !1, !2. Seal kit includes a grease pack (5 g). Order with the following part number when only the grease pack is needed.
Compact and Lightweight Auto Switch Sensing Optional Non Rotating Piston Rod Optional High Accuracy Mounting M A D E I N USA S Y M B O L S Double Acting/Single Rod Single Acting/Spring Return H O W T O O R D E R NCJ2 S TA N D A R D D O U B L E A C T I N G S I N G L E R O D C Y L I N D E R Double Acting/Single Rod Non-Rotating NC J2 S P E C I A L O P T I O N S NC J2 XB6 High Temperature XB7
Bore size (in) Standard stroke 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 1.50 2, 2.50 3.25, 4 How to Order NCA1 Mounting Bore Stroke N XB7 Standard Ex: NCA1B 150-0400N-XB7 Low temperature Auto switch capable not available 6-15-24 24 Series NCA1 Oversized Rod Specifications 2 2.5 3.25 4 Bore