Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0400 (4 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 1500 (15 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1500 (15 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0600 (6 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0800 (8 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 1000 (10 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 2500 (25 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0200 (2 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1500 (15 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 1200 (12 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 1500 (15 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, LE, 32MM NCY2S DBL-ACT AUTO-SW, 13.50529 lb
Band Mount: None, Rail Mount: A73H--Reed, 24VDC max, 100VAC max, LED, Lead Wire, Horizontal, Tie-rod Mount: None, Direct Mount: None, Lead Wire: Z (5m)
Sensor Type: Contacting, Output Format: PNP Format, Wiring Method: 3-Wire, Type: Main Body, Electrical entry direction: In-line, Lead wire length(m): 5, Applicable load: Relay / PLC, Load Voltage: 24 V DC / 100 V AC
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, LE, 32MM NCY2S DBL-ACT AUTO-SW, .00000 lb