V(mm/s) = x 1000 In case of high pison speed, the use of an auto switch (DF7NT and G5NT) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Keep wiring as short as possible.

Model: MRQBS32-50CA-A73 Operating pressure: 0.5 MPa MSU CRJ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CRA1 Calculate the amount of air requirement for A, B, C and D respectively.

V (mm/s) = Auto switch operating range (mm) Load operating time (ms) x 1000 In case of high piston speed, the operating time of the load can be extended by using an auto switch (D-F7NT) with built-in OFF delay timer (approx. 200ms). 4. Keep wiring as short as possible.

/Mounting Method Applicable cylinder -X2321/-X2322 -X2321/-X2322 -X2321/-X2322 Applicable auto switches D-P3DWAl D-M9lV/M9lWV D-A73/A79W Bore size [mm] 32 32 32 Auto switch mounting bracket part no.

) (1000) (1000) (1000) MY1MW20 MY1MW20 30 30 (1000) (900) (1000) (900) (1000) (900) (1000) (900) Caution MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 MY1CW16 (900) (900) (900) (900) 20 20 1.

FL1 (A) F1 K (mm) (H) A F1 H FL1 16.5 K 3 Bore size Stroke range 24 32 40 51 21 Up to 1000 22 18 54.5 3 22.5 Up to 1000 : Same as the standard model. 1896

Note 2) The maximum limit is 1000 stroke, but the products that exceed the standard stroke might not be able to fulfill the specifications. Tightening Torque: Tighten the cylinder mounting bolts for the bottom mounting Style (Series CM2RA) with the following tightening torque.

E D LY 4-LD LH MM Width across flats KA 18 N N S + Stroke LX Y X Y X LS + Stroke ZZ + Stroke LT B C (mm) AL Bore size Stroke range Symbol B B1 C D E GA GB H H1 J K KA MM N P LD A LS LH LT LX LY S X Y ZZ 6 40 3.2 1/4 42 Up to 1000 14 27 30 27 60 70 22 44 9 16 32 27 33 15 51 8 M8 x 1.25 13 102 193 40 156 M14 x 1.5 7 45 3.2 3/8 50 Up to 1000 18 30 35 32 70 80 27 52 9 20 40 27 35 17 58 11 M8

200, 250, 300 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 MGGL Ball bushing 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

Applicable models: D-A73/A73H/A73C D-A93/A93V 2) Note however, that in the case of 2 color indication auto switches (D-A79W), the switch will be in a normally ON condition if the wiring is reversed.

Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.

To adjust the cylinder speed, use a speed controller. 30 20 CXW32 10 CXWL25 CX2N25 Load mass (kg) CXW20 CX2N25-B, CXWM25 5 CXW16 4 CX2N15-B CX2N15 3 2 CX2N10-B CX2N10 CXW10 1 0.5 10 50 100 200 300 500 1000 Cylinder speed (mm/s) 462 Series CX2 Prior to Use 1. Changing from the non-auto switch specifications to the auto switch specifications 2.

To adjust the cylinder speed, use a speed controller. 30 20 CXW32 10 CXWL25 CX2N25 Load mass (kg) CXW20 CX2N25-B, CXWM25 5 CXW16 4 CX2N15-B CX2N15 3 2 CX2N10-B CX2N10 CXW10 1 0.5 10 50 100 200 300 500 1000 Cylinder speed (mm/s) 462 Series CX2 Prior to Use 1. Changing from the non-auto switch specifications to the auto switch specifications 2.

Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.

MK2T Max. piston speed Average piston speed Note 1) Total stroke Note 2) Stroke time Note 3) Model MK 115 mm/s 72 mm/s 25 mm 0.35 seconds CK1 1.0 x 104 Note 1) Average piston speed = Max. piston speed 1.6 Note 2) Total stroke = Clamp stroke + Rotary stroke Note 3) Total stroke Average piston speed The stroke time should be longer than the above mentioned stroke time. 115 200 CLK2 10 100 1000

If operated beyond the limiting ranges, excessive impact will occur and this may cause damage to equipment. 100 Lateral load F (N) 80 10 CUJ 63 CU 50 CQS Operating pressure 0.5 MPa Operating pressure 0.4 MPa Graph (1) 40 32 25 CQ2 1000 20 1 10 100 300 RQ Stroke + Eccentric distance (mm) CQM Cushion Needle Adjustment Caution 100 MU 100 Load mass kg 80 63 50 1.

Applicable models: D-A73, A73H, A73C, C73, C73C, Z73 D-A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a two color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.

Auto switch operating range (mm) _ Load operating time (ms) Operating current of load (OFF condition) > Leakage current V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3-wire switch if this specification will not be satisfied.

When bank 2 is selected Decimal no. 1 2 3 4 5 6 7 8 9 0 BCD 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 16 17 18 19 20 Bank 2 Bank 3 Bank 4 11 12 13 14 15 Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 6 7 8 9 10 Bank 1 1 2 3 4 5 RS-232C 1 2 3 4 5 Output terminal 6 7 8 9 10 Preset no.

lead wire and case) Withstand voltage 10 to 60C Ambient temperature IEC60529 Standard IP67 (2) Enclosure 1) Electrical entry: Connector type (A73C/A80C/C73C/C80C): 1000 VAC/min.