SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S25H-0400-A80"

Applicable Cylinder Series: CDQ2 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V D-F7/F7V/J79/J79C/F7W J79W/F7WV/D-F7BA/F7BAV F79F/F7NT/D-A7/A80/A7H A80H/A73C/A80C/A79W D-P3DW Applicable auto switch 32 to 100 Bore size (mm) Auto switch mounting bracket part no.

For detailed specifications, refer to page 6-16-1. 20Data Electrical entry Type Model Features D-A80 D-A80H D-A80C D-C80 D-C80C D-F7NTL Grommet Without indicator light Connector Grommet Connector Grommet Reed switch Solid state switch With timer With pre-wire connector is available for D-F7NTL type, too.

MB1 CA2 Contact Protective Box/Internal Circuit CS1 CD-P11 Operating Range of Auto Switch (mm) C76 Brown lead wire Bore Surge absorber Choke coil Model Mounting 32 40 C85 Blue lead wire 8 D-C7/C80/C73C/C80C 8 5 D-H7/H7W/H7BAL 4.5 Band C95 10 9 D-H7C CD-P12 D-A7/A80/A7H/A80 8 8 CP95 (+) Brown lead wire Choke coil D-A73C/A80C 14 13 D-A79W Rail NCM () Blue lead wire D-F7/J79/F7W/J79W 6.5 6 D-F7V

MB1 CA2 Contact Protective Box/Internal Circuit CS1 CD-P11 Operating Range of Auto Switch (mm) C76 Brown lead wire Bore Surge absorber Choke coil Model Mounting 32 40 C85 Blue lead wire 8 D-C7/C80/C73C/C80C 8 5 D-H7/H7W/H7BAL 4.5 Band C95 10 9 D-H7C CD-P12 D-A7/A80/A7H/A80 8 8 CP95 (+) Brown lead wire Choke coil D-A73C/A80C 14 13 D-A79W Rail NCM () Blue lead wire D-F7/J79/F7W/J79W 6.5 6 D-F7V

Contact protection box CD-P11 Data LED Brown OUT Brown Choke coil Resistor Reed switch Zener diode Surge absorber OUT Blue Blue Weight (g) D-A73 D-A72 D-A73 D-A80 Auto switch model 10 10 10 0.5 Lead wire length (m) 47 47 47 3 LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 77 5 Resistor Reed switch Zener diode Dimensions OUT () Blue Blue Indicator light D-A80 without indicator

In-line 3 wire (NPN) C76 A76H 5V IC Yes Reed switch Solid state switch A72 A73 A80 A73C A80C A79W F7NV F7PV F7BV J79C F7NWV A72H A73H A80H 200V Ex.

Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection 20 32 to 100 D-A7 D-A80 Approx. U B A Approx. U A B D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U Approx. U Approx. U SMC SMC Approx. U A B B A Approx. U D-A73C D-A80C D-J79C B A A B Approx.

Applicable Cylinder Series: CDQ2 D-F7/F7V/J79/J79C/F7W J79W/F7WV/D-F7BA/F7BAV F79F/F7NT/D-A7/A80/A7H A80H/A73C/A80C/A79W D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V Applicable auto switch D-P3DWA Bore size (mm) 32 to 100 Auto switch mounting bracket part no.

D-F7 D-J79 D-F7WV D-F7BAV D-A79W D-A9/D-A9V 10 15 10 + 15 (n2)Note) (n=4, 6...) 5.5 6 6.5 6.5 D-A7/A80 D-A7H/A80H D-A73C/A80C 7.5 8 8.5 8.5 D-F7W/J79W D-F7BA D-F79F/F7NT 15 + 20 (n2)Note) (n=4, 6...) 10 15 D-A79W 10 10.5 12.5 12.5 5 10 10 + 15 (n2)Note) (n=4, 6...)

Auto Switches/Proper Mounting Position for Stroke End Detection B A (mm) Dimension A Dimension B Auto switch model D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-F7W/J79W D-F7WV D-F7LF Note 2) D-F7W/J79W D-F7WV D-F7LF Note 2) D-A73/A80 D-A73/A80 D-F7NTL D-F7NTL D-F79F D-F7BAL D-F79F D-F7BAL Bore size (mm) 6 23 23.5 45 44.5 27.5 40.5

D-A7H/A80H D-A73C/A80C D-F7LF D-F79F Bore size (mm) B A 10 6 3 4.5 (mm) 15 6 4 4.5 Dimension A Dimension B 20 6 3 4.5 Auto switch model D-A72 D-A72 25 6 3 4.5 D-F7W/J79W D-F7WV D-F7LF Note 1) D-F7W/J79W D-F7WV D-F7LF Note 1) D-F79F D-F7BAL D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V 32 6 3 4.5 D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 40 6 3.5 4.5

D-A72/D-A73/D-A80 Band Mounting Style . D-A7xH/D-A80H Rail Mounting Style. D-A73C/D-A80C Rail Mounting Style .

D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W 12 12 12 11 10 12 13 13 13 14 14 16 5 5 5 D-P4DWL 16 Series MK/MK2 Auto Switch Mounting Bracket/Part No.

Note 2) These figures show the dimensions when equipped with D-A73 or D-A80 auto switches.

MVGQ Indicator light D-A80 without indicator light D-A80 CC 15 (14) RB 23 (22) OUT () Brown Contact protection box CD-P11 CD-P12 Reed switch J OUT ( ) Blue D6 (6.2) 3 -X 9 (8.5) Most sensitive position Note 1) Operating load is an induction load.

light D-A80 without indicator light D-A80 Data 15 (14) 23 (22) OUT () Brown Contact protection box CD-P11 CD-P12 Reed switch OUT ( ) Blue 6 (6.2) 3 9 (8.5) Most sensitive position Note 1) Operating load is an induction load.

Contact protection box CD-P11 LED Brown OUT Brown Choke coil Resistor Reed switch Zener diode Surge absorber OUT Blue Blue Weight (g) D-A73 D-A72 D-A73 D-A80 Auto switch model 10 10 10 0.5 Lead wire length (m) 47 47 47 3 LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 77 5 Resistor Reed switch Zener diode Dimensions OUT () Blue Blue Indicator light D-A80 without indicator

Contact protection box CD-P11 Data LED Brown OUT Brown Choke coil Resistor Reed switch Zener diode Surge absorber OUT Blue Blue Weight (g) D-A73 D-A72 D-A73 D-A80 Auto switch model 10 10 10 0.5 Lead wire length (m) 47 47 47 3 LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 77 5 Resistor Reed switch Zener diode Dimensions OUT () Blue Blue Indicator light D-A80 without indicator

light D-A80 without indicator light D-A80 15 (14) 23 (22) OUT () Brown Contact protection box CD-P11 CD-P12 Reed switch OUT ( ) Blue 6 (6.2) 3 9 (8.5) Most sensitive position Note 1) Operating load is an induction load.

Contact protection box CD-P11 Data LED Brown OUT Brown Choke coil Resistor Reed switch Zener diode Surge absorber OUT Blue Blue Weight (g) D-A73 D-A72 D-A73 D-A80 Auto switch model 10 10 10 0.5 Lead wire length (m) 47 47 47 3 LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 77 5 Resistor Reed switch Zener diode Dimensions OUT () Blue Blue Indicator light D-A80 without indicator