SMC Corporation of America
Elite Part Number Search
Search Results "NCDMB125-1000-A93"

20 1000 1500 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 25 1500 2000 32 40 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 2000 1500 50 63 Note) Contact SMC if the maximum stroke will be exceeded.

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the

50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)

50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)

CE2 ML2B Graph (1) Graph (2) RSA50, 63, 80 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 C J G5-S 1.0 1300 1300 RSH80 RSA80 RSH63 RSA63 RSH50 RSH50 RSA50 80 0.9 Operating pressure P [MPa] 1200 1200 CV 0.8 1100 1100 0.7 MVGQ 1000 1000 0.6 900 900 0.5 CC 63 80 Load weight m [kg] Load weight m [kg] 800 800 0.4 50 0.3 RB 700 700 0.2 600 600 J 0.1 63 500 500 50 1000 2000 3000 4000 5000

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

Cylinder speed-1000 mm/sec. Sequencer response time-0.1 sec. Detecting point despersion-Within 100mm (=1000 mm/sec. X 0.1sec.) Take PLC response time into consideration when using.

Auto Switch Internal Circuit D-A90(V) Contact protection box OUT () Brown Reed switch Unit: g Weight CD-P11 OUT () Blue CD-P12 D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Auto switch model Lead wire length: 0.5 m 6 6 6 6 8 8 D-A93(V) Lead wire length: 3 m 30 30 30 30 41 41 LED diode Brown OUT (+) Brown Contact protection box Resistor Unit: mm Dimensions Reed switch Zener diode CD-P11 D-A90/D-A93

Auto switch model Auto switch 63 32 40 50 9 4 7 11 32 40 50 63 D-A93 D-M9B D-M9BW D-B54 8 4 6.5 10 8 3.5 5.5 10 8 4 5 9 D-A93 D-M9B D-M9BW D-B54 Note) Note) Note) Note) qBMA2-032 wBJ3-1 qBMA2-040 wBJ3-1 qBMA2-050 wBJ3-1 qBMA2-063 wBJ3-1 BA-32 BA-04 BA-05 BA-06 Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.)

63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

L1 L2+A5 L3 2 1 W V 2 E= ( ) 2 9.8 1000 Collision speed V=1.4 Va *) Corrected coeficient 1 420 E= 1( ) =0.088 2 1000 V=1.4 X 300=420 Calculate kinetic energy E (J) of work. Calculate allwable kinetic energy Ea (J). Check that kinetic energy of work does not exceed allowable kinetic energy.

(between lead wire and case) 1000 VAC for 1 min.

Examine for My My=10(10+30)/1000=0.4 A3=30 Examine for My My=10(30+10)/1000=0.4 A6=10 M=W(Ln+An)/1000 Corrected value for center position distance of moment An: Table 3 Calculate allowable static moment Ma(Nm) Ma=K Mmax Work mounting coeficient K: Fig.3 Allowable moment coeficient : Graph 2 Max. allowable moment Mmax: Table 4 2=M/Ma May=1 x 1 x 15.9=15.9 Mymax=15.9 K=1 =1 2=0.4/15.9=0.0252

1000 1000 2.0 2.0 2.0 2.0 800 LC7 1.5 1.5 1.5 1.5 LC8 1000 1.0 1.0 1.0 1.0 LXF 0.5 0.5 0.5 0.5 LXP 0 0 500 1000 0 0 500 1000 0 0 500 1000 0 0 500 1000 LXS Stroke (mm) Stroke (mm) Stroke (mm) Stroke (mm) Note) Tact time may vary depending on the load mass or sliding resistance and thus value is not guaranteed.

D-A90, A90V Contact protection box OUT () Brown Reed switch CD-P11 OUT () Blue CD-P12 Weights Unit: g D-A93, A93V Auto switch part no.

D-A90(V) OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT() Blue Weight (g) D-A93(V) Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Brown OUT (+) Brown 41 Lead wire length (m) 0.5 6 6 6 6 8 8 Contact protection box CD-P11 CD-P12 Resistor 3 30 30 30 30 41 Reed switch Zener diode Dimensions (mm) OUT () Blue Blue D-A90/D-A93/D-A96 2 2.8 4.5 2.7 D-A96(V) DC (+) Brown 4 LED

Up to 1000 Up to 1000 Up to 1000 Up to 1000 Up to 800 Up to 800 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Double clevis style: (D) A clevis pin and 2 cotter pins are included.