light 8 3.2 DC (+) Brown 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 2.6 DC () Blue 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV Precautions OUT (+) Brown Be sure to read before handling.
Contact P/A in this case. 1 Guide Cylinder Series MGG Models and Specifications JIS symbol Models and strokes Long stroke (mm) Standard stroke (mm) Model Bearing type Bore size (mm) 20 250, 300, 350, 400 75, 100, 125, 150, 200 25 350, 400, 450, 500 MGGM Slide bearing 32 350, 400, 450, 500, 600 40 350, 400, 450, 500, 600, 700, 800 75, 100, 125, 150, 50 350, 400, 450, 500, 600, 700, 800, 900
Bore (mm) Standard stroke (mm) Nylon tarpaulin 60C 110C Neo plain cloth 25, 50, 75, 100, 125, 150, 175, 200, 250, MG 40 Maximum ambient temperature for the rod boot itself. 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, MGP 50, 63 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, MGQ 80, 100 300, 350, 400, 450, 500, 600, 700 MGG Minimum stroke of
Both directions Lock direction MXW MXP Stroke Bearing Standard stroke (mm) Long stroke (mm) Bore size (mm) MG Model MGP 20 75, 100, 125, 150, 200 250, 300, 350, 400 MLGCM Slide bearing 25 350, 400, 450, 500 MGQ 75, 100, 125, 150, 32 350, 400, 450, 500, 600 MLGCL Ball bushing bearing 200, 250, 300 40 350, 400, 450, 500, 600, 700, 800 MGG * Middle strokes and short strokes other than shown
350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 700, 800 200, 250, 300 MGCL Ball bushing baering 350, 400, 450, 500, 600, 700, 800, 900, 1000 *Short stroke or intermediate stroke(except above stroke): Manufactured upon receipt of order 3.20-2 Compact Guide Cylinder Series MGC Specifications MGCll20 MGCll25 MGCll32 MGCll40 MGCll50 Model CDGIBA20 CDGIBA25 CDGIBA32 CDGIBA40
Indicator light DC (+) Brown 8 3.2 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 DC () Blue 2.6 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV OUT (+) Brown Precautions Be sure to read before handling.
light 8 3.2 DC (+) Brown 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 2.6 DC () Blue 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV Precautions OUT (+) Brown Be sure to read before handling.
light 8 3.2 DC (+) Brown 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 2.6 DC () Blue 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV Precautions OUT (+) Brown Be sure to read before handling.
Lead wire (m) Load voltage Auto switch model Indicator Applicable load Style Special function Wiring (Output) Electrical entry Applicable bore size 0.5 () 3 (L) 5 (Z) None (N) DC AC 20 to 63 20 to 100 3 wire (NPN) C76 IC 5V Yes B53 PLC B54 12V Grommet 200V or less Reed switch Solid state switch No B64 12V 100V Yes C73 2 wire 24V Relay PLC 5V, 12V 100V or less No IC C80 12V Yes C73C
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 100 (1"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 200 (2"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 300 (3"), Port Location: R (In-line), Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 600 (6"), Port Location: R (In-line), Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 400 (4"), Port Location: R (In-line), Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M
Magnet: D (Built-in), Mounting: L (Foot), Bore: Ø16 (5/8 Inch), Stroke: 200 (2 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100
Magnet: D (Built-in), Mounting: L (Foot), Bore: Ø16 (5/8 Inch), Stroke: 200 (2 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100
Magnet: D (Built-in), Mounting: L (Foot), Bore: Ø16 (5/8 Inch), Stroke: 500 (5 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100
Magnet: Built-in, Mounting: Foot, Bore: Ø16 (5/8 Inch), Stroke: 2 Inch, Action: Spring Return, Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Foot, Bore: Ø16 (5/8 Inch), Stroke: 2 Inch, Action: Spring Extend, Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: -, Number: -