SMC Corporation of America
Elite Part Number Search
Search Results "NCDJ2B16-600-C76"

/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80 1400 C95 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175

Ball bushing bearing MLGCL 200, 250, 300 Bore size (mm) Auto switch model D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700, 800 20 25 32 40 BMA2 -020 BA -01 BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

Switches with an indicator light (except D-A56/A76H/ A96/A96 V/C76/E76A/Z76) If auto switches are connected in series as shown below, please note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to internal voltage drop in the auto switch specifications.)

Basic mass (500 st) 2.44 (kg) (Foot style 32) Additional mass 0.09 (kg/50 st) Cylinder stroke 600 (st) 2.44 + 0.09 x (600 500)/50 = 2.62 kg REA REB Copper and Fluorine-free Air Cylinder REC Mounting style Bore size Stroke Suffix 20 RHC CY Copper and fluorine-free CX The type which prevents copper based ions from generating by changing the copper based materials with electroless nickel

Mass (g) Size Standard mass 90 180 10 120 150 15 220 270 20 600 700 30 900 1100 40 1400 1600 Not including the mass of auto switch. D319 Series CRQ2X Rotation Range When pressurized from the port indicated by the arrow, the shaft will rotate in a clockwise direction.

Basic weight 500 st 2.44 (kg) (Foot style 32) Additional weight 0.09 (kg/50 st) Cylinder stroke 600 (st) 2.44 + 0.09 x (600 500)/50 = 2.62 kg Accessory Mounting nut Rod end nut 30 30 d d D D C C H H B B Material: Carbon steel Material: Carbon steel B Part no.

Ball bushing bearing MLGCL 200, 250, 300 Bore size (mm) Auto switch model D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700, 800 20 25 32 40 BMA2 -020 BA -01 BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

Graph (1) 10 500 st 600 st 700 st 700 st 500 st 600 st 400 st 400 st 4 5 300 st 300 st 3 200 st 200 st Load movement time: t (S) 2 100 st [Example] Example) 1 0.4 0.5 0.3 V' 0.2 300 0.1 V W 100 200 1000 400 500 Maximum speed: V (mm/s) Cylinder stroke Movement distance of load Step (2) Find the bore size.

Graph (1) 10 500 st 600 st 700 st 700 st 500 st 600 st 400 st 400 st 4 5 300 st 300 st 3 200 st 200 st Load movement time: t (S) 2 100 st Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com [Example] Example) 1 0.4 0.5 0.3 V' 0.2 300 0.1 V W 100 200 1000 400 500 Maximum

(Atlanta) 1440 Lakes Parkway, Suite 600 Lawrenceville, GA 30043 Tel: (770) 624-1940 FAX: (770) 624-1943 16850 W. Victor Road New Berlin. Wl 53151 Tel: (414) 827-0080 FAX: (414) 827-OO92 5377 Glen Alden Drive Richmond, VA 23231 Tel: (804) 222-2762 FAX: (80a) 222-5221 SMC Pneumatics Inc.

1) Auto switch with an indicator light (Except D-A56, A76H, A96, A96V, C76, E76A, Z76) If auto switches are connected in series as shown below, take note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to the internal voltage drop in the auto switch specifications.)

Electrical entry (Direction) Features D-C73, C76 Reed Without indicator light D-C80 Grommet (In-line) D-H7A1, H7A2, H7B Solid state D-H7NW, H7PW, H7BW D-H7BA Diagnostic indication (2-color) For solid state auto switches, auto switches with a pre-wired connector are also available. Refer to pages 1014 and 1015 for details.

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: Ø10 (3/8"), Stroke: 600 (6"), Port Location: Perpendicular, Auto Switch: C76--Reed, DC Volt <5, LED, Lead Wire, 0.5M

Features Electrical entry (Fetching direction) D-B53, C73, C76 Reed Without indicator light D-C80 D-H7A1, H7A2, H7B Grommet (In-let) Diagnostic indication (2-color) D-H7NW, H7PW, H7BW Solid state With timer D-G5NTL For solid state auto switches, auto switches with a pre-wired connector are also available. Refer to pages 1784 and 1785 for details.

locking Pneumatic locking Spring and Pneumatic locking Fine lock cylinders Series CLJ2 MLU 15 to 200 Double acting Single rod Both directions ML1C 9-2-10 16 D-X Series CLM2 20 25 32 40 25 to 300 20Double acting Single rod Both directions 9-2-17 Data Series CLG1 20 25 to 200 25 32 40 Double acting Single rod Both directions 25 to 300 9-2-27 Lock-up cylinder Series CL1 25 to 500 40 25 to 600

Lead wire length (m) Load voltage Indicator light Auto switch model Pre-wire connector Applicable load Special function Type Electrical entry Wiring (Output) AC DC 0.5 (Nil) 3 (L) 5 (Z) None (N) 3-wire (NPN equivalent) C76 5 V IC circuit Grommet C73 B54 C73C A33 A34 A44 B59W H7A1 H7A2 H7B H7C G39 K39 H7NW H7PW H7BW H7BA H7NF 100 V Solid state switches marked with are produced upon receipt

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 100 (1"), Port Location: Perpendicular, Auto Switch: C76--Reed, DC Volt <5, LED, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 150 (1 1/2"), Port Location: R (In-line), Auto Switch: C76--Reed, DC Volt <5, LED, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 200 (2"), Port Location: Perpendicular, Auto Switch: C76--Reed, DC Volt <5, LED, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: C76--Reed, DC Volt <5, LED, Lead Wire, 0.5M