Magnet: Built-in, Mounting: Double Clevis, Cushion: Air Cushion, Bore Size: 1 1/4", Stroke: 4", Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Front Flange, Cushion: Air Cushion, Bore Size: 3/4", Stroke: 4", Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Foot, Cushion: Air Cushion, Bore Size: 1", Stroke: 4", Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Inches) Bore 150 200 250 325 400 * available for 200 and 250 bores only ** use single rod designation when ordering XC11 kit Note: XC10 seal kit order 2 single rod kits *** not available with K option How To Order Tie Rods NC1A 150 11 2759 0400 How To Order Cylinder Tube Double Acting Single Rod Stroke (In Inches and Hundredths of Inches) NC1A 150 04 0400 Applicable Bore Tie Rod Size Bore
Bore size (in) 1.50 2, 2.50 3.25, 4 Standard stroke 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How to Order Mounting Bore Stroke NC D A1 XC35 Ex: NCDA1B 150-0400-XC35 With coil scraper Auto switch capable 6-15-33 33 Series NCA1 Accessory Bracket Dimensions Eye Bracket Part no.
Bore size (in) 1.50 2, 2.50 3.25, 4 Standard stroke 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How to Order Mounting Bore Stroke NC D A1 XC35 Ex: NCDA1B 150-0400-XC35 With coil scraper Auto switch capable 6-15-33 33 Series NCA1 Accessory Bracket Dimensions Eye Bracket Part no.
10 0618 1560 -10 -5 -20 0 0 -10.5 -5.25 -21 Byte0 Byte1 CH0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB Byte2 Byte3 CH1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB -21No.EX-OMN0037CN-A (2)2 2 010 V05 V020 mA 15 V420 mA AD (ab) AD (0b) [V] [mA] 16 10 [V] [mA] 16 10 15 V 420 mA 010 V 05 V 020 mA 07FF 2047 5.25 21 07FF 2047 10.5 5.25 21 078E 1934 5 20 079E 1950 10 5 20 0400
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCG ROUND BODY CYLINDER, HE, 20MM NCG DBL-ACT AUTO-SW, .00000 lb
NCA 500 Zinc chromated Tie rod Carbon steel 4 19 Rod seal NBR 1 20 Stroke (In inches and hundredths) Bore 500 600 800 Gland seal NBR 1 21 22 Cushion seal Urethane 2 Cylinder tube gasket NBR 2 23 NCA 500 RG Bore 500 600 800 Special options Nil XB5 XC35 XB5C35 Standard Oversized rod Coil scraper Oversized W/ Coil scraper NC A 500 26A 0400 D NCA 500 11 0400 B Special options Nil XB5 XB6 XB7
A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
D-A90 cannot be mounted on Series MY1HT.
Special function Electrical entry Wiring (Output) Lead wire length (m) Auto switch model Load voltage DC Perpendicular In-line AC Applicable load Pre-wired connector Indicator light Type 3(L) SDPC Reed switch Solid state switch Diagnostic indication (2-color indication) M9BWV M9BW Yes 24 V 12 V Relay, PLC Grommet 2-wire A90 No IC circuit 100 V or less *Additional symbols for auto switch
Auto Switch Specifications Grommet Electrical entry : In-line PLC: Abbreviation for Programmable Logic Controller D-A90/D-A90V (without indicator light) D-A90/D-A90V Auto switch part no.
A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indicator) Grommet Yes A79W V V 1 Water resistant type auto switches can be mounted on the above models, but SMC cannot guarantee water resistance.
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
CXSJ10 D B (mm) D-A90, D-A96 25.7 29.7 3.2 D-A93 25.7 27.2 5.7 D-F9 29.7 2.8 19.7 7.2 Symbol A B Note) C D A C Note) For D-A90, D-A96, and D-A93, only outward electrical entry (D dimension) is available.
47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
Franklin Rd Indianapolis, IN 46226 Tel: (317) 899-4440 FAX: (317) 899-3102 http://www.smcusa.com SMC Pneumatics (Canada) Ltd. 6768 Financial Drive, Mississauga, Ontario L5N 7J6 Tel: (905) 812-0400 FAX: (905) 812-8686 http://www.smcpneumatics.ca All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing.