Magnet: Built-in, Mounting: Rear Pivot, Bore Size: 3/4in, Stroke: 6in, Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Double End, Bore Size: 1 1/4", Stroke: 6in, Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 075 (3/4in), Stroke: 0600 (6in), Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: C (Rear Pivot), Bore Size: 075 (3/4in), Stroke: 0600 (6in), Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 125 (1 1/4"), Stroke: 0600 (6in), Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Series: Standard w/ Magnet, Mounting: MT1, Rod Trunnion, Bore Size: 3 1/4", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, X Option: -
Series: Standard w/ Magnet, Mounting: MF1, Front Flange, Bore Size: 4", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, X Option: -
Series: Standard w/ Magnet, Mounting: MF1, Front Flange, Bore Size: 2 1/2", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, X Option: -
Series: Standard w/ Magnet, Mounting: MP1, Double Rear Clevis, Bore Size: 1 1/2", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, X Option:
Series: Standard w/ Magnet, Mounting: MP1, Double Rear Clevis, Bore Size: 3 1/4", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, X Option:
Series: Non-rotating w/ Magnet, Mounting: MX0, Basic, Bore Size: 1 1/2", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, X Option: -
30 s Switching the signal type of the contact input 1 OFF/RN.ST/ RUN/SW/ RN.ST Switching the signal form of the contact input 1 ALT/MT ALT Contact type switching of contact input 1 A/B A Alarm switching for contact input 1 OFF/WRN/FLT OFF Communication Delay time setting for contact input 1 0600 0 s Setting Menu Chapter 5.8 OFF detection time setting for contact input 1 010 0 s Switching
(6") 075 (3/4") 088 (7/8") 106 (1-1/16") 125 (1-1/4") 150 (1-1/2") 200 (2") 0050 (1/2"), 0100 (1"), 0150 (1-1/2"), 0200 (2"), 0250 (2-1/2"), 0300 (3"), 0400 (4"), 0600 (6") Double acting Double rod 075 (3/4") 088 (7/8") 106 (1-1/16") 125 (1-1/4") 150 (1-1/2") 0050 (1/2"), 0100 (1"), 0200 (2"), 0300 (3"), 0400 (4"), 0500 (5") 0600 (6") Single acting Single rod Now available in 8 different
Step Request data Response data Operation details 01 10 0600 000A Alarm history command to clear alarm 14 0 0 0 0 1 01 10 0600 000A history sent. (0 to 10 entries) 0 0 0 0 0 0 01 10 060A 000A Alarm history command to clear alarm 14 0 0 0 2 01 10 060A 000A history sent. (11 to 20 entries) 0 0 0 0 0 0 0 67 - Caution Ensure the alarm history is cleared only after taking corrective action in
Magnet: D (Built-in), Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke: 0050 (1/2")
Magnet: D (Built-in), Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke: 0100 (1")
Magnet: D (Built-in), Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke: 0200 (2")
Magnet: D (Built-in), Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke: 0300 (3")
Magnet: D (Built-in), Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke: 0500 (5")
Magnet: D (Built-in), Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke: 1200 (12")