400 500 600 700 800 900 1000 50 100 150 200 300 400 500 600 700 800 900 32 40 50 63 80 100 125 48 4 15 75 250 225 200 175 188 313 150 163 288 125 138 263 23 100 113 238 36 75 100 213 54 12.5 37.5 50 88 54 4 17 75 250 225 200 175 188 313 150 163 288 125 138 263 23 100 113 238 36 75 100 213 54 12.5 25 37.5 50 88 69 5 24 87 250 225 200 175 200 325 150 175 300 125 150 275 25 100 125 250 51 75
160 180 200 220 240 260 280 300 320 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 901 to 1000 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 165 A ISO Standard (15552) Air Cylinder: Standard Type Double Acting, Single/Double Rod C96 Series Dimensions Basic:
325 63 51 64 25 12.5 25 37.5 50 75 100 125 150 175 200 225 250 87 100 112 125 150 175 200 225 250 275 300 325 80 56 68 30 12.5 25 37.5 50 75 100 125 150 175 200 225 250 103 116 128 141 166 191 216 241 266 291 316 341 100 56 76 32 12.5 25 37.5 50 75 100 125 150 175 200 225 250 103 116 128 141 166 191 216 241 266 291 316 341 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500
depth 12 6 14 50 Up to 300 301 to 1500 35 32 27 32 20 30 2 14 58 11 58 M8 x 1.25 depth 16 7 18 63 Up to 300 301 to 1500 35 32 27 38 20 32 2 14 58 11 72 M10 x 1.5 depth 16 7 18 80 Up to 300 301 to 1500 40 37 32 50 25 40 3 20 71 13 89 M10 x 1.5 depth 22 10 22 100 Up to 300 301 to 1500 40 37 41 60 30 50 3 20 71 16 110 M12 x 1.75 depth 22 10 26 CG3 JMB MB MB1 * For mounting brackets, refer to
Type Lube Non-lube Air-hydro 125 140 160 Bore size Nil N H Lube, Non-lube Air-hydro 125 140 160 180 200 250 300 125 mm 140 mm 160 mm 180 mm 200 mm 250 mm 300 mm 125 mm 140 mm 160 mm Mounting Bracket Part No. 125 140 160 180 200 250 300 Bore size (mm) For How to Order with auto switch, refer to page 6-9-7.
(mm) Bore size (mm) Stroke range (mm) AL AK AP AJ AI AH AG N AB M AA L K J I V B U T A O P S 63 80 100 12 14 60 180 158 250 228 100 25 66 25 180 135 117 65 108 228 192 30 M12 x 1.75 depth 23 Rc 1/4 200 72 75, 100, 125 150, 200, 250 300 16 14 70 200 178 284 262 115 27 76 30 214 160 138 75 128 262 224 M12 x 1.75 depth 28 Rc 3/8 35 230 89 16 16 80 226 200 326 300 125 30 80 32 245 190 153 85
Magnet: None, Mounting: F (Rod Flange), Bore Size: 50mm, Thread: TN (NPT), Stroke: 300mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: No Bracket, Rod End Bracket: W (Double Knuckle Joint)
Magnet: None, Mounting: Rod Flange, Bore Size: 50mm, Thread: NPT, Stroke: 300mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: No Bracket, Rod End Bracket: Double Knuckle Joint, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
301 to 400 20 to 300 301 to 400 22 19.5 17 45 104 1/8 51.5 20 12 18 2 97 10 (12) 25 6.5 9 7 10 6 38 Up to 300 301 to 450 20 to 300 301 to 450 30 27 19 52 112 1/8 58.5 26 16 25 2 104 10 (13) 26 7 11 7 12 8 47 Up to 300 301 to 800 20 to 300 301 to 800 Without rod boot With rod boot Bore size (mm) P J K KA MM NA PG PH PL S TA TB TC XA XB l ZZ H e f h ZZ 20 25 32 40 M4 x 0.7 depth 7 5 6 M8 x
After installing the snap ring, make sure that it is placed securely in the ring groove before supplying air. 32 to 100 101 to 300 32 to 100 105 to 300 Model no. : CQ2A50-165DC-XB10 Makes 165 stroke tube. B dimension is 220.5mm. Model no. : CQ2A50-165DC CQ2A50-17DC with 10mm width spacer. B dimension is 230.5mm.
Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Max. speed (mm/s) Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 6 (7) (8) (9) 10 15 Selection graph 20 (10) (11) (12) (13) (14) (15) (17) (16) 25 32 The maximum speeds for 10 to 32 are
If operated beyond the limiting ranges, excessive impact will occur and this may cause damage to equipment. 100 Lateral load F (N) 80 10 63 50 40 32 25 Operating pressure 0.5MPa Operating pressure 0.4MPa Graph 1 20 1 10 100 300 1000 Stroke + Eccentric distance (mm) Cushion Needle Adjustment 100 Caution 100 Load weight kg 80 1.
D-X 100 Lateral load F (N) 2080 10 Data 63 50 Operating pressure 0.5 MPa Operating pressure 0.4 MPa 40 32 25 Graph (1) 1000 20 1 10 100 300 Stroke + Eccentric distance (mm) Cushion Needle Adjustment 100 100 Load weight kg Caution 80 63 50 1.
When exceeding 300 stroke, the allowable maximum stroke length is determined by the stroke selection table.
/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175
/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175
Relationship of liquid entry and sliding distance X Amount of liquid entry (g) 15 10 Standard cylinder Stainless steel cylinder 5 0 50 100 150 200 Sliding distance (km) 250 300 Conditions Working fluid ...Air Pressure .. 0.5MPa Liquid ...
CRJ 400 CRA1 Displacement (m) Displacement (m) CRQ2 MSQ 250 MSZ 350 CRQ2X MSQX MRQ 200 300 30 25 20 15 10 5 0 40 30 20 10 0 Load (N) Load (N) MSQXB30A MSQXB50A 350 300 300 250 Displacement (m) Displacement (m) 250 200 200 150 150 D100 100 100 80 60 40 20 0 50 40 30 20 10 0 Load (N) Load (N) 329 Series MSQX Construction o i w@3 r !
Body Port size : Standard typerindividual gilot exhaust ut subplate _,,' (a --1ry1 wv l--l l ? l H R port lpE port M:Common exhaust for main and pilot valve M5:10-32 with Nom.