(mm) Auto Switch Mounting Height D-A9l(V) D-M9l(V) D-M9lW(V) D-M9lA(V) D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 Auto switch model D-B5l D-B64 D-B59W D-G5NT D-H7C D-G39A D-K39A D-A3lA D-A44A D-C73C D-C80C Hs Hs Hs Hs Hs 20 24.5 25.5 25 60 69.5 25 27 28 27.5 62.5 72 32 30.5 31.5 31 66 75.5 40 34.5 35.5 35 70 79.5 Bore size D-X Technical Data 263 CM2 Series Auto Switch Proper Mounting Position
How to Order R 6N 1 1 D B 25 50 LEY X5 o Made to Order: Dust-tight/ Water-jet-proof q w e r t y u i !0 !1 !2 !
clearance hole / NC(D)Q8N(Z)S T (Inch) Symbol Bore E 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.20 0.25 0.25 0.34 0.34 0.41 43 Series NCQ8 Dimension Both ends tapped NC(D)Q8A-(C)(M) NC(D)Q8WA-(C)(M) NC(D)Q8A-S(M) NC(D)Q8A-T(M) Both Ends Tapped (Inch) O1 R Bore size Remarks R R O1-Thread 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2")
/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
(S, R, RS) P PG PH 1 2 U D B (-D) When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
R Y + Stroke View D-D' 63 to 100 Reinforcing bracket Mounted in case of 301mm or longer strokes Front mounting flange Width across flats HT B HS C D View C-C' HU D' C' A R Y + Stroke View D-D' Auto switch mounting position Auto switch mounting height (mm) (mm) D-A72, A7H, A80H D-A73C, A80C D-F7, F7V, F7W D-F7WV, F7BAL D-J7 D-A7H, J79W D-A80H, F7BAL D-F7, F7F D-J79, F7NTL D-F7W D-A7, A8 D-F7V
For details about auto switches, refer to the Web Catalog. stroke range [mm] LEY25 15 to 400 LEY32 20 to 500 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 * Please consult with SMC for non-standard strokes as they are produced as special orders. 544 Electric Actuator/Rod Type 25A-LEY Series AC Servo Motor 25, 32 Size Secondary
Axial 2 3 4 5 2m 3m 4m 5m F R L T B Axial entry Right entry Bottom entry Specifications Intermediate strokes 100 5.5 200 6.3 300 7.1 400 7.8 500 8.6 5 to 40 (with no condensation) 10 225 400 0.02 AC servomotor (100W) Incremental system Ground ball screw 12mm, 8mm lead High rigidity direct acting guide With coupling Standard stroke mm kg C kg N mm/s mm For manufacture of strokes other than
Auto Switch Mounting Height [mm] Auto switch model D-F5m D-J59 D-F59F D-F5mW D-J59W D-F5BA D-F5NT D-Y59m D-Y7P D-Y7mW D-Y7BA D-Z7m D-Z80 D-M9m D-M9mW D-M9mA D-A9m D-A9mV D-M9mV D-M9mWV D-M9mAV D-A5m D-A6m D-A59W D-Y69m D-Y7PV D-Y7mWV D-P3DWA D-P4DW D-G39 D-K39 D-A3m D-A44 Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23 30.5 23 32.5 25 35 24.5 67 27.5 77
There may be large variations depending on the surrounding environment (variations on the order of 30%). 66 Solid State Switches/Direct Mount/ D-Y59 /D-Y69 /D-Y7P(V) Series MGP Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
D C B A 91 Series LTF Construction Construction LTF6/LTF8 e t w !0 i r !3 q !4 !2 !8 !7 !2 y o !1 !6 !5 u Parts list No. Description No.
B (S, R, RS) (-D) Stations When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.
15 Auto switch model Bore size (mm) D-A9 A dimension D-M9 B dimension C dimension D dimension D-A9 D-M9 D-A9 D-M9 D-A9 D-M9 21.5 76.5 72.5 56.5 60.5 17.5 15 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8
case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 103 103 47 47 78 78 22 32 30.5 117.5 117.5 55.5 55.5 92.5 92.5 30.5 Operating Range Bore size (mm) Auto switch model 32 25 15 D-A9 8 D-M9 3 D-Z7/Z8 9 9 D-Y5/Y6/Y7 6 7 Since this
D-K59W D-G5NTL D-B5/B6 D-B59W D-G5BAL D-G59F MGT Auto switch model Auto switch model D-G59F D-G5 D-K59 D-G5W D-K59W D-G5NTL D-G5BAL D-C7 D-C80 D-H7 D-H7W D-H7HF D-H7BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-C7 D-C80 D-C73C D-C80C D-A9 D-M9 D-M9W D-M9 D-M9W D-B5 D-B64 D-B59W D-C73C D-C80C D-A9 Bore size (mm) Bore
KN-10-600 KN-12-350 KN-12-400 KN-12-600 KN-16-400 KN-16-600 KN-20-400 KN-20-600 D H2 H1 L2 L1 Nozzle with male thread/KN (mm) Model Nozzle size D Connection size L1 A Width across flats H1 Connection thread 1 1.5 1 1.5 2 2.5 6 4 6 4 6 6 8 8 R 1/8 R 1/8 R 1/4 R 1/4 R 1/4 R 1/4 R 1/4 R 3/8 R 3/8 R 1/2 R 1/2 R 3/4 R 3/4 R 1 10 10 14 14 14 14 14 17 17 22 22 27 27 36 21.4 21 31.4
Example) S2S2: Standard cable (2 m) + Driver (LECSS2) S2 : Standard cable (2 m) Nil : Without cable and driver Stroke (mm) Model 200 300 400 500 700 600 800 900 1000 1200 1500 2000 3000 LEJB40 LEJB63 D ) D D D ) ) D D D D ) ) D D ) ) D ) D D D D D 3: Strokes other than those shown above are produced as special order (1 mm increments). For auto switches, refer to pages 19, 20.
CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Auto Switch Mounting Height (mm) MB D-Z7/Z-80 D-Y59 D-Y7P D-Y7W D-F5, D-J5 D-F59F D-F5W, D-J59W D-F5BAL, D-F5NTL D-A5 D-A6 D-A59W D-A3 D-G39 D-K39 D-Y69 D-Y7PV D-Y7WV Bore size D-Y7BAL D-A44 D-P5DWL MB1 (mm) Ht Hs
2 t r @2 @1 #3 #4 #1 @9 #2 D-X @5 @7 @4 @6 20Data @3 CY1H10-B CY1H10-BS @8 #0 t CY1H10CY1H10 Material Note Component Parts No. q w e r No. !8 !