SMC Corporation of America
Elite Part Number Search
Search Results "MGZF50-300-A93LS"

Magnet: Built-In, Mounting: Front Flange, Style: Non-lube Rubber Bumper, Bore Size: 32mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 300mm, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., X Option: -

Magnet: Built-In, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 40mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 300mm, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., X Option: -

Magnet: Built-In, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 20mm, Thread: NPT, [ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion, Piping: Screw-in Piping, Stroke: 300mm, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., X Option: -

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):

Mounting: F (Front Flange), Bore Size: 50mm, Port Thread: M5x0.8 (20), Rc (25~80), Coil Scraper: Without, Stroke: 400mm, Auto Switch: M9BAV--Solid State, Water Resist., 2 Wire, Vertical

Mounting: F (Front Flange), Bore Size: 50mm, Port Thread: M5x0.8 (20), Rc (25~80), Coil Scraper: Without, Stroke: 75mm, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Mounting: F (Front Flange), Bore Size: 50mm, Port Thread: M5x0.8 (20), Rc (25~80), Coil Scraper: Without, Stroke: 400mm, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Mounting: Front Flange, Bore Size: 50mm, Port Thread: M5x0.8 (20), Rc (25~80), Coil Scraper: Without, Stroke: 400mm, Auto Switch: M9BAV--Solid State, Water Resist., 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Mounting: Front Flange, Bore Size: 50mm, Port Thread: M5x0.8 (20), Rc (25~80), Coil Scraper: Without, Stroke: 75mm, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Mounting: Front Flange, Bore Size: 50mm, Port Thread: M5x0.8 (20), Rc (25~80), Coil Scraper: Without, Stroke: 400mm, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Mounting: Front Flange, Bore Size: 50mm, Port Thread: M5x0.8 (20), Rc (25~80), Coil Scraper: Without, Stroke: 100mm, Auto Switch: Y69B--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: D (Built-in), Mounting: B (Standard), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: Rc, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: L (3m Lead Wire), Number: S (1 pc.), Lock Unit Built-in Magnet

Magnet: D (Built-in), Mounting: B (Standard), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: TN (NPT), Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: L (3m Lead Wire), Number: S (1 pc.), Lock Unit Built-in

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: Rc, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 1 pc., Lock Unit Built-in Magnet: Built-in, Lock

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 1 pc., Lock Unit Built-in Magnet: Built-in, Lock

The MGZ series is a non-lube double power air cylinder available in both rotating and non-rotating styles. The MGZs unique design doubles the pressurized area for extension making the MGZ an ideal cylinder for lifting and pressing operations. The front end lock style MGZ holds the rod when extended. Non-rotating double power cylinder, Bore sizes (mm): 20, 25, 32, 40, 50, 63, 80, Standard

The MGZ series is a non-lube double power air cylinder available in both rotating and non-rotating styles. The MGZs unique design doubles the pressurized area for extension making the MGZ an ideal cylinder for lifting and pressing operations. The front end lock style MGZ holds the rod when extended. Non-rotating double power cylinder, Bore sizes (mm): 20, 25, 32, 40, 50, 63, 80, Standard

The MGZ series is a non-lube double power air cylinder available in both rotating and non-rotating styles. The MGZ's unique design doubles the pressurized area for extension making the MGZ an ideal cylinder for lifting and pressing operations. The front end lock style MGZ holds the rod when extended. Non-rotating double power cylinder, Bore sizes (mm): 20, 25, 32, 40, 50, 63, 80, Standard