L A93L Note) Refer to P. 177 to 179 for further information of auto switch. PLC: Programmable Logic Controller Specifications Specifications are same as the standard type.
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 50mm, Port Thread: Rc, Stroke: 600mm, Rod Boot: None, Lock Style: HN (With Rear End Lock Non-locking Style), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,
1/8 HN-T1 1/8 HNX1 1/8 HN-T2 1/8 HN-T4 Page 10 Distributed by Power Aire, Inc
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 28 55.5 + Stroke 83.5 + Stroke MB MB1 CA2 CS1 C76 C85 C95 CP95 With head end lock: CBJ2B16-HN NCM NCA 0 h8-0.022 10 6 2-M10 x 1 Piping port 2-M5 x 0.8 D8 M5 x 0.8 20 -X 19.8 205 Data 0 -0.3 18.3 12.5 15 8 12.5 50 + Stroke 8 28 86 + Stroke 6-3-79 80 80
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Y Z 2-M5 x 0.8 2-RB G G HT U (NA) (Option) A L HN (Max.)
Piping port 2-M5 x 0.8 8 M5 x 0.8 20 19.8 5 0 -0.3 18.3 12.5 15 8 12.5 50 + Stroke 8 28 86 + Stroke 3 Series CBJ2 Dimensions Flange With front end lock / CBJ2F16-RN 14.5 M10 x 1 Cover side (rear side) Piping port 2-M5 x 0.8 5 6 20 M5 x 0.8 20.3 19 20 2-5.5 Mounting hole 2.3 9.5 0 -0.3 18.3 15 8 21 33 42 55.5 + Stroke 28 Cover outside diameter 83.5 + Stroke With rear end lock / CBJ2F16-HN
This is a legacy product, and replaced byNCDRA1BS50-90CZ-A93L NCRA ROTARY ACTUATOR. NCRA 50 SGL/DBL ROD W/AUTO-SW. ACTUATOR. 50MM NCRA DBL-ACT AUTO-SW. 3.30000 lb. NE.
This is a legacy product, and replaced byMGPM20-125Z-A93L MGP COMPACT GUIDE CYLINDER. CYL, COMPACT GUIDE, SLIDE *LQA. ACTUATOR. 20MM MGP SLIDE BEARING. 3.57060 lb. HM.
F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil 3 m L 5 m Z (Example) A93 (Example) A93L
Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes Relay, PLC 100 V 24 V M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes Relay, PLC 24 V M9B 2-wire 12 V Lead wire length symbols 0.5 mNil (Example) A93 3 mL A93L
switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols: 0.5 mNil (Example) A93 3 m L (Example) A93L
Load voltage Auto switch model Electrical entry direction Indicator light Electrical entry Special function Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12V In-line Yes Grommet 24V 100V 12V Reed switch 2-wire Relay, PLC A93 3-wire (NPN) M9N Yes Grommet 24V Solid state switch Relay, PLC 2-wire 12V M9B Lead wire length symbols: 0.5mNil (Example) A93 3 m L (Example) A93L
length (m) Load voltage Auto switch model Electrical entry direction Indicator light Electrical entry Wiring (Output) Special function 0.5 Nil 3 (L) Applicable load Style 5 (Z) AC DC 12V Horizontal Yes Grommet 2-wire Relay, PLC 24V 100V 12V Reed switch A93 3-wire (NPN) M9N Yes Grommet Relay, PLC 24V Solid state switch 2-wire 12V M9B Lead wire symbol 0.5mNil (Example) A93 3mL A93L
F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil 3 m L 5 m Z (Example) A93 (Example) A93L
switch Grommet (Perpendicular) IC circuit D-A90V-588 48 V 24 V or less 48 V or less No 2-wire D-A93-588 Relay, PLC 12 V 24 V Yes Grommet (in-line) IC circuit D-A90-588 48 V 24 V or less 48 V or less No D-M9PV-588 Grommet (Perpendicular) IC circuit 3-wire (PNP) Yes 5 V, 12 V 24 V D-M9P-588 Grommet (in-line) Lead wire length symbols: 0.5 m Nil (Example) D-A93-588 3 m L (Example) D-A93L
A93 3 m L A93L Relay PLC 24 V 12 V Grommet Diagnostic indication (2 color indication) Yes 3-wire (NPN) 3-wire (PNP) 2-wire Refer to pages 8-30-1 for detailed auto switch specifications. 8-24-3 4 Series MGT Model Applicable auto switch Bearing type Turntable Bore size (mm) Cylinder Model Reed switch Solid state switch Reed switch Solid state switch Slide bearing Ball bushing bearing MGTM
F9PW F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L