SMC Corporation of America
Elite Part Number Search
Search Results "LEY63DS4B-600F-S5A2H"

Magnet: None, Mounting: Basic, Bore Size: 50mm, Port Thread: Rc, Stroke: 600mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: None, Mounting: Foot, Bore Size: 80mm, Port Thread: Rc, Stroke: 600mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: None, Mounting: Foot, Bore Size: 32mm, Port Thread: NPT, Stroke: 600mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: Built-in, Series: Standard, Mounting: Double Clevis, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø50, Port Thread: NPT, Stroke: 600mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Series: Standard, Mounting: Double Clevis, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø50, Port Thread: Rc, Stroke: 600mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Series: Standard, Mounting: Double Clevis, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø80, Port Thread: Rc, Stroke: 600mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: B (10mm), Stroke: 200mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 2m

Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: B (10mm), Stroke: 200mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 2m, Driver Type: A2 [LECSA2/Pulse

Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: B (10mm), Stroke: 200mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange), Cable Type: S (Standard Cable), Cable Length: 2m, Driver Type: A2 [LECSA2

Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: B (10mm), Stroke: 500mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 2m

Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: B (10mm), Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 2m, Driver Type: A2 [LECSA2/Pulse

Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: B (10mm), Stroke: 300mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/vent hole tap), Motor Option: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange), Cable Type: S (Standard Cable), Cable Length: 2m, Driver

Accuracy: Basic, Motor Mounting Position: D (In-Line), Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: B (10mm), Stroke: 300mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/vent hole tap), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard