Proof pressure Operating temperature 0 to 200C Burst Pressure and Heat Resistance Performance 4.0 3.5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3.0 2.5 Pressure (MPa) 2.0 1.5 1.0 0.5 0 20 40 60 80 100 120 140 160 180 200 Temperature (C) 1/8", 3/16", 1/4", 4,
Compatibility is indicated for fluid temperatures of 200C or less. The material and fluid compatibility check list provides reference values as a guide only, therefore we do not guarantee the application to our product. The data above is based on the information presented by the material manufacturers.
The recommended operating temperature ceiling is 200C. Several variations of Chemraz are available and it is advisable to make a selection based upon the particular plasma being used and other conditions, etc. Chemraz is a registered trade mark of Greene, Tweed & Co.
This is a legacy product, and replaced byCP96SDB80-200C-XC68, SeriesDescriptionModelActionNoteVol. no. (for std model)CP95ISO cylinderCP95SDouble acting, Single rod--666
This is a legacy product, and replaced byC96SDT63-200C-X46US-149 ISO TIE ROD CYLINDER. "CYLINDER.
This is a legacy product, and replaced byC96SDB32-200C C95/C96 TIE-ROD CYLINDER. CYL, TIE ROD, ISO, AUTO-S *LQA. ACTUATOR. 32MM C95/CP95 DBL-ACT AUTO-SW. 2.64554 lb. LE.
This is a legacy product, and replaced byCP96SDB40-200C C95/C96 TIE-ROD CYLINDER. CYL, PROFILE, ISO. ACTUATOR. 40MM C95/CP95 DBL-ACT AUTO-SW. 3.71743 lb. ME.
Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied. T unit Can be connected with PLC I/O card for serial transmission. EX300-TMB1For models of Mitsubishi Electric Corp. EX300-TTA1For models of OMRON Corp. EX300-TFU1For models of Fuji Electric Company Ltd.
No. of output points, 16 points Master station: PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations Stations are counted from station 1 on the D side.
MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 16 outputs, 2 occupied stations Connect to the I/O card of transmission PLC manufacturers to enable serial transmission. EX300-TMB1for Mitsubishi Electric Corporation EX300-TTA1.for OMRON corporation EX300-TFU1.for Fuji Electric Co., Ltd. EX300-T001.
Item Specification MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 16 outputs, occupying two stations Connection to T unit PLC manufacturer's I/O card enables serial transmission. EX300-TMB1 ... for Mitsubishi Electric Corporation EX300-TTA1 ... for OMRON Corporation EX300-TFU1 ... for Fuji Electric Co., Ltd. EX300-T001 ...
ERR Item Specifications MELSECNET/MINI-S3 Data Link System Master unit : AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output points, 16 points, No. of stations. occupied, 2 stations Connection to T unit PLC manufacturers I/O card enables serial transmission. EX300-TMB1 for Mitsubishi Electric Corporation EX300-TTA1 for OMRON Corporation EX300-TFU1 for Fuji Electric Co., Ltd.
EX300-T001General purpose MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output point, 16 points No. of sta. occupied, 2 stations Each T unit has 32 control points.
Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied.
A Controller type Motor type Power supply voltage Symbol Type AC servo motor (S2) Capacity Encoder LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8 AC servo motor (S2) 100 to 120 VAC 50/60 Hz S1 S3 S4 S5 S7 S8 100 W B Pulse input type (For absolute encoder) AC servo motor (S3) Pulse input type (For incremental encoder) Incremental AC servo
EX300-TMB1For models of Mitsubishi Electric Corporation EX300-TTA1For OMRON EX300-TFU1For Fuji Electric EX300-T001General purpose T units have 32 control points per unit No. of output points, 16 points Master station PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points).
Master station PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations T unit Can be connected with PLC I/O card for serial transmission.
Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 Without cable Without cable With cable (1.5 m) With cable (3 m) With
Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 Without cable Without cable With cable (1.5 m) With cable (3 m) With
3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 5.20 5.40 5.60 5.80 6.00 6.20 6.40 6.60 6.80 7.00 7.20 S7 3.34 3.54 3.74 3.94 4.14 4.34 4.54 4.74 4.94 5.14 5.34 5.54 5.74 5.94 6.14 6.34 6.54 6.74 6.94 7.14 Motor type T7 3.31 3.51 3.71 3.91 4.11 4.31 4.51 4.71 4.91 5.11 5.31 5.51 5.71 5.91 6.11 6.31 6.51 6.71 6.91 7.11 Additional weight for lock[kg] S3:0.4/S7:0.7/T7:0.5 Series LEFS40 Stroke[