At the setting of STA 20, STB 5000 and STC 200, the actual arc part times are as follows. (Example) Limited to 100[ms] since During acceleration: 100[ms] 20 20 100[ms] 200[ms]. 200[ms] as set since During deceleration: 200[ms] 20 5000 400[ms] 200[ms].
250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure
0.03 mm 0.30 0.03 0.15 0.20 0.02 0.10 0.01 mm 0.10 0.01 0.05 0.05 mm 0.02 mm 0 0 0 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Piping length: 5 m Piping length: 5 m Piping length: 5 m Reference pressure 0.06 Reference pressure 0.30 Reference pressure 0.60 The distance of switch ON [mm]
Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p
300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
Port P Port R2 Unit mounting position IP65 available Kit T1 With terminal blocks 1 to 12 stations D side U side Without SI unit With general purpose type SI unit Mitsubishi: MELSECNET/MINI-S3 data link system Mitsubishi: MELSECNET/MINI-S3 data link system (2 power supply systems) OMRON: SYSBUS wire system Sharp: Satellite I/O link system NKE: Simplified wiring (16 point output) Sanks: S-LINK
Port P Port R2 Unit mounting position IP65 available Kit T1 With terminal blocks 1 to 12 stations D side U side Without SI unit With general purpose type SI unit Mitsubishi: MELSECNET/MINI-S3 data link system Mitsubishi: MELSECNET/MINI-S3 data link system (2 power supply systems) OMRON: SYSBUS wire system Sharp: Satellite I/O link system NKE: Simplified wiring (16 point output) Sanks: S-LINK
30 50 100 150 200 250 300 30 50 100 150 200 250 300 Product weight [kg] 1 1.14 1.37 1.66 1.83 1.7 1.89 2.21 2.63 2.97 3.31 3.57 2.95 3.21 3.76 4.32 4.99 5.48 5.92 Series LEYG16LmE LEYG25LmE LEYG32LmE Stroke [mm] 30 50 100 150 200 30 50 100 150 200 250 300 30 50 100 150 200 250 300 Product weight [kg] 1.01 1.14 1.31 1.6 1.75 1.71 1.92 2.16 2.59 2.85 3.17 3.41 2.95 3.22 3.61 4.16 4.7 5.21
suppressor AC ( Hz) 50 60 1 100 VAC 2 200 VAC With light/surge voltage suppressor YOZ is not available.
Nil 3 rotations setting 200 setting 3 rotations setting 200 setting 3 rotations setting 200 setting 18 rotations setting 18 rotations setting E14 1 point setting E15 With analog output 2 points setting E16 E17 Electronic (12 to 24 VDC) 1 point setting E18 E19 With analog output With analog output With analog output Switch model 1 point setting M15 Diaphragm solid state switch (10 to 26 VDC
After returning to the origin position, the SETON and INP signals are output. 0 Absolute: 200 Operation w [Specify Step No.2 to input the DRIVE signal.] 200 Absolute: 100 Step data No. defining operation The operation starts by specifying a registered step data No. to input the DRIVE signal.
V JEM-TR225-2007 200 V 7 2 (1) [Pr.
S3 32 200 S3 200 to 230VAC LECSA2 A2 200 to 230VAC LECSA2 A2 Both side D Both side D 40 400 S4 40 400 S4 100 to 120VAC 100 to 120VAC LECSB1 LECSB1 B1 B1 25 100 S6 25 100 S6 Motor option 32 200 S7 AC servo motor (Absolute encoder 32 200 S7 AC servo motor (Absolute encoder LECSB2 LECSB2 200 to 230VAC B2 200 to 230VAC B2 B1,B2 B1,B2 Without lock Nil Without lock Nil 400 400 40 40 S8 S8 Cable
Repetition Pressure characteristics Flow characteristics Supply pressure: 0.2 MPa Set pressure: 0.05 MPa Relief flow characteristics Supply pressure: 0.2 MPa 1.0 0.25 0.15 Output deviation factor (%F.S.) 0.20 0.5 Set pressure (MPa) Set pressure (MPa) 0.10 Set point 0.15 0.0 0.10 0.05 0.5 0.05 1.0 0 200 400 600 0.00 0.0 0.1 0.2 0.3 600 0 200 400 800 Flow rate (L/min (ANR)) Flow rate (L/min
Electric Actuator/High Rigidity Slider Type Ball Screw Drive Series LEJS AC Servo Motor (100/200 W) RoHS How to Order LEJS 40 500 A S2 Motor type 1 Size Lead [mm] 40 63 A B LEJS40 16 8 LEJS63 20 10 Symbol Symbol Type Actuator size Output [W] AC servo motor (Incremental encoder) AC servo motor (Incremental encoder) Compatible drivers 2 S2 LECSA;-S1 100 40 Stroke [mm] 3 S3 LECSA;-S3 200
00-A-5 0 0 200 400 600 800 1000 1200 1400 VQ45 (Plug lead type) B ARBQ4000-00-B-5 Flow rate (l/min(ANR)) P ARBQ4000-00-P-5 ARBQ4000-00-P (P B) 0.7 Outlet pressure (MPa) 0.6 SMC 0.5 0.4 0.3 0.2 50 147 0.1 0 0 200 400 600 800 1000 1200 1400 B 2 SMC Flow rate (l/min(ANR)) 12 1 P 5 3 R2 R1 Pressure Characteristics 59 PE 4 A Conditions Inlet pressure: 0.7 MPa Outlet pressure: 0.2 MPa Flow rate
LECSA-S3 63 200 Without lock Nil With lock B LECSB-S5 LECSC-S5 LECSS-S5 40 AC servo motor (absolute encoder) S6 100 *3 (6) Vacuum port direction Left side Nil LECSB-S7 LECSC-S7 LECSS-S7 AC servo motor (absolute encoder) S7 Right side R 63 200 Both side D *1 Fo r mo tor type S 2 and S6, note that the com patible driv er part number suffix is S1, S5. *3When v acuum ov er 50L/m in( ANR), select
Station Address S1 S2 00H to 02H: Disabled 0 0 to 2 (Do not use these addresses.) 03H (Factory setting) 0 3 04H 0 4 EFH E F F0H to FFH: Disabled F 0 to F (Do not use these addresses.) (2) Settings of the DIP Switch S3 The following table shows the settings of the DIP switch (S3). Switch No.
W 400 W 100 W 200 W 400 W Type AC servo motor (S2) AC servo motor (S3) AC servo motor (S4) AC servo motor (S6) AC servo motor (S7) AC servo motor (S8) Symbol C S1 S3 S41 SSCNET III type (For absolute encoder) Incremental S S5 S7 S81 Power supply voltage Absolute 1 2 100 to 120 VAC, 50/60 Hz 200 to 230 VAC, 50/60 Hz 1 Not applicable for Series LEY Dimensions LECSAm 40 135 2 x 6 Mounting hole
Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable Without cable Without cable With cable (1.5 m) With cable (3 m) With cable (5 m) Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2