Regenerative power [W] Built-in regenerative Driver LEC-MR-RB-032 LEC-MR-RB-12 [40] [40] resistor LECSB-S5 30 LECSB-S7 10 30 100 LECSB-S8 10 30 100 Note 1. Always install a cooling fan. 2.
40 30 20 10 Step 1 Check the speedwork load.
JSY1000 series clamp bracket Wiring (JSY1000 series) JSY11M-15P-1A JSY11M-15P-2A F D-sub connector V Pm Flat ribbon cable V TC Spring type terminal block box V T Terminal block box V L Lead wire V S6 EX600 V Sm EX250 V Smm EX260 V S3 EX120 V Manifold Parts Nos.
IS Below set position OK ZSM PF2 W IF Data Energy consumption can be reduced compared with the conventional models (Conventional models: 50 kPa) 30 kPa Minimum operating pressure 30 kPa (ISA2-G) Position of supply port: Either right side or left side is available.
58.5 41.6 46.2 1.6 3.5 12 11 66 H 5.5 40.4 29 24 16 64.4 (Max. 67.4) 24 3.1 33 52.5 30 Supply port ISA3-C: Rc1/4 ISA3-F: G1/4 1 Detection port ISA3-C: One-touch fitting ISA3-F: G1/8 2 38 13 L2 (49) ISA3-mmm-mmmB-R1m ISA3-mmm-mmmB-R2m 29.3 L1 46.2 41.6 58.5 30 30 52.5 Supply port ISA3-C: Rc1/4 ISA3-F: G1/4 1 Supply port ISA3-C: Rc1/4 ISA3-F: G1/4 1 ISA3-mmm-mmmB-LNm ISA3-mmm-mmmB-RNm 44.6
30 30 0.1MPa 20 20 20 0.15MPa 0.15MPa 0.15MPa 10 10 10 0.2MPa 0.2MPa 0.2MPa 100 200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
Station Address S1 S2 00H to 02H: Disabled 0 0 to 2 (Do not use these addresses.) 03H (Factory setting) 0 3 04H 0 4 EFH E F F0H to FFH: Disabled F 0 to F (Do not use these addresses.) (2) Settings of the DIP Switch S3 The following table shows the settings of the DIP switch (S3). Switch No.
EXH port P1 SUP port Sensor S1 S3 S2 S4 P2 Detection port S1, S2: Fix orifice S3: Variable orifice (adjusted by setting dial) S4: Detection nozzle 868 A Air Catch Sensor Series ISA2 Wiring Individual wiring Centralized wiring Terminal block 1: Brown 2: NC 3 0 1 2 3 4 Brown Blue Black DC (+) NC DC () OUT ZSE30 ISE30 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 6 9 3: Blue DC () NC DC (+) OUT 6 ZSE40 ISE40
Port P Port R2 Unit mounting position IP65 available Kit T1 With terminal blocks 1 to 12 stations D side U side Without SI unit With general purpose type SI unit Mitsubishi: MELSECNET/MINI-S3 data link system Mitsubishi: MELSECNET/MINI-S3 data link system (2 power supply systems) OMRON: SYSBUS wire system Sharp: Satellite I/O link system NKE: Simplified wiring (16 point output) Sanks: S-LINK
500 500 0 0 0 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14 0 5 10 15 20 25 30 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 2000 2000 2000 2000 Mey 1500 1500 1500 1500 L5 [mm] L5 [mm] L5 [mm] L5 [mm] m 1000 1000 1000 1000 Wall L5 Y 500 500 500 500 0 0 0 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14 0 5 10 15 20 25 30 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work
How to Order Connector Assembly For DC: SY100 30 4A For 100 VAC: SY100 30 1A Groove Cover For 200 VAC: SY100 30 2A Pin Cover For other voltages of AC: SY100 30 3A Groove DC polarity display Lever Pin Without lead wire: SY100 30 A Lead wire length -+ Socket (with connector and 2 of sockets only) Lead wire Connector Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000
LEC-CSS-L 11.2 11.2.1 [W] LECLECMR-RB-032 MR-RB-12 [40] [40] LECSS2-T5 30 LECSS2-T7 10 30 100 LECSS2-T8 10 30 100 LECSS2-T9 20 30 100 11 8 11. 11.2.2 [Pr. PA02] [Pr. PA02] 0 0 00: 100W 200W, 400W, 750W 02:LEC-MR-RB-032 03:LEC-MR-RB-12 11.2.3 11.5 100 5m 11 9 11. (1) LECSS2-T P+DP+CG3G4 G3G4 P+D P+D P P+ C C G3 D (3) (1) G4 5m 5 m (12) 1.
This control is not for synchronizing the position of the main axis and slave axis. 10 10 Current position Current position Origin 0 0 Origin 10 20 30 40 50 Axis 1 10 20 30 40 50 Axis 1 For 3 Axes JXC92 Series For 4 Axes JXC73/83/93 Series VParallel I/O/ V Type V Width: Approx. 38% reduction Type V Width: Approx. 18% reduction 78 47 mm shorter 140 30 mm shorter JXC92 JXC73/83 170 125 *
Master station PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations T unit Can be connected with PLC I/O card for serial transmission.
Master station PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations T unit Can be connected with PLC I/O card for serial transmission.
Description Applicable model ITV10 P398010-600 Flat bracket assembly (including mounting screws) ITV30 ITV20, 30 P398020-600 ITV10 P398010-601 L-bracket assembly (including mounting screws) ITV20, 30 P398020-601 [Cable connector] 243 Part No.
30 e Valve Model Fill in the blanks below with symbols of necessary specifications.
6 1000 20 5 100 30 4 10 50 6 1000 5 5 100 15 4 10 30 6 1000 20 5 100 50 4 10 60 6 1000 10 5 100 40 4 10 50 6 1000 50 5 100 80 4 10 100 LEFS16 500 500 LEFS25 900 500 Please aspirate it from the port on both sides when aspirating 50 /min(ANR).
Nil W 2-5-5 Base Mounted Series VQ4000 Plug-in/Plug Lead: Single Unit Plug Lead Type Grommet 0 1 G H 2 position single: VQ415 155.5 105.5 155.5 105.5 42.5 50 42.5 50 Indicator light 23.5 23.5 11 (12.5) 11 (12.5) 2(B) port 4(A) port VQC 5 3 4 2 SQ 9 38 48 A B 38 24.6 10.5 48 11 1 A 4 2 VQ0 3 5 1 14 12 13.5 13.5 30 45 2-5.6 Mounting hole 30 45 VQ4 2-5.6 Mounting hole Manual override 5-Rc 1/
Crean class Amount of Type Speed recommended vacuum (mm/s) ISO 14644-1 Fed.Std.209D aspiration 6 1000 10 5 100 20 4 10 30 6 1000 50 5 100 60 4 10 70 6 1000 20 5 100 30 4 10 50 6 1000 30 5 100 70 4 10 90 600 11-LEJS40 1200 600 *Please aspirate it from the port on both sides when aspirating 50/min(ANR). Please select "D" about the type. 11-LEJS63 1200 * Based on SMC test condition.