SMC Corporation of America
Elite Part Number Search
Search Results "LEFS40REB-850"

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

1100 242 342 402 452 115 230 400 560 242 342 402 452 115 230 400 560 850 1100 23 Series HRG Operation Panel Display HRG001/002/005 No.

Bore size (mm) Standard stroke (mm) Range of manufacturable stroke* Without rod boot With rod boot Without rod boot With rod boot 40 25 to 850 25 to 700 Up to 1200 Up to 950 50 25 to 800 25 to 650 Up to 1150 Up to 900 63 25 to 800 25 to 650 Up to 1150 Up to 900 80 25 to 750 25 to 600 Up to 1100 Up to 900 100 25 to 750 25 to 600 Up to 1100 Up to 850 Refer to pages 692 to 697 for cylinders

T dimension) None Differential pressure indicator Differential pressure indication switch Note) 0 1 5 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) 30 FH FH Note) N.C. and N.O. common Note) When the differential pressure indication 1 or 5 is selected, the connection method is 2 to 5. (0 and 1 cannot be selected.)

/1070 850/1070 1300/1700 2000/2500 Three-phase 200 V IDG Operating current (A) 50/60 Hz 4.3/4.7 4.3/4.7 Single-phase 200 V 3.3/3.5 3.3/3.5 5.0/5.4 7.2/8.0 Three-phase 200 V AMG Applicable circuit breaker capacity Note 5) (A) 10 (200 VAC) 15 (200 VAC) AFF Condenser Air-cooled Refrigerant R407C (HFC) AM Auto drain Float type (Normally open) Port size R 1 1/2 R 2 R 1 AMD (kg) Mass 62 54 116

217 229 Built-in one-touch fittings 12 12 21 21 162 177 192 208 223 238 254 269 284 300 Foot (Incl. mounting bolts) 153 242 316 604 227 247 266 286 306 326 345 365 385 404 504 658 240 261 283 305 326 348 369 391 413 434 546 Rod flange (Incl. mounting bolts) 213 372 558 1041 433 466 499 532 565 598 630 663 697 869 Head flange (Incl. mounting bolts) 1124 1321 622 660 698 736 774 812 850

Foot (Including mounting bolts) 153 242 316 604 227 247 266 286 306 326 345 365 385 404 504 Rod flange (Including mounting bolts) 213 372 558 658 240 261 283 305 326 348 369 391 413 434 546 Head flange (Including mounting bolts) 198 348 534 1041 433 466 499 532 565 598 630 663 697 869 Double clevis (Including pin, retaining rings and bolts) 196 393 554 1124 1321 622 660 698 736 774 812 850

A.850: Encoder Overspeed (Detected when the control power supply was turned ON.) (Detected on the encoder side.) Turn the power supply OFF and then ON again. If the alarm still occurs, the servomotor may be faulty. Replace the servomotor. An encoder fault occurred. Turn the power supply OFF and then ON again. If the alarm still occurs, the DRIVER may be faulty. Replace the DRIVER.

A.850: Encoder Overspeed (Detected when the control power supply was turned ON.) (Detected on the encoder side.) Turn the power supply OFF and then ON again. If the alarm still occurs, the servomotor may be faulty. Replace the servomotor. An encoder fault occurred. Turn the power supply OFF and then ON again. If the alarm still occurs, the DRIVER may be faulty. Replace the DRIVER.

/ 1070 810 / 940 850 / 1070 1450 / 1890 2000 / 2500 Circuit Breaker(Note 3) A 10 15 Condenser Air cooling Refrigerant R407C (HFC) Refrigerant Charge g 42010 47010 73010 83010 55010 72010 Air IN/OUT Connection R1 R11/2 R2 Drain Connection mm 10 Coating Color Panel: Urbanwhite 1 Base: Urbangray 2 Weight kg 54 62 100 116 Applicable Compressor(Standard) kW 22 37 55 75 Note1: The data for m3/

/ 1070 810 / 940 850 / 1070 1450/1890 2000/2500 (3) A 10 15 R407C (HFC) g 42010 47010 73010 83010 55010 72010 R1 R11/2 R2 mm 10 1 2 kg 54 62 100 116 kW 22 37 55 75 1ANR 2065% 2 3 30mA 4() 6-2 GWP (GWP) Regulation (EU) No 517/2014 IPCC AR4) R134a 1,430 1,430 R404A 3,922 3,920 R407C 1,774 1,770 R410A 2,088 2,090 (1) (2) IDF Series 6-1 6 1 IDX-OM-W026 6 6-3 IDF22E, IDF37E

For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.

Max. operating frequency Not required Lubrication Double acting Action Solid state auto switch (3-wire, 2-wire) Auto switch (Option) Note) Note) Refer to pages 797 to 850 for further information on auto switches.

Finger option Action Nil: Standard tapped mounting 2: Through-holes in opening/closing direction D Double acting Applicable Auto Switches / Refer to pages 797 to 850 for further information on auto switches.

wedgewire style desiccant retainers P/A's pneu alpha programmable controller Port size 1 1/2" NPT 1 1/2" NPT 2 1/2" NPT 3" Flange 3" Flange 4" Flange 4" Flange 6" Flange 1/2" NPT 3/4" NPT 1" NPT 2" NPT 2" NPT 2" NPT Oil-dust tight EEMAC-12 control panel 40F pressure dew points and lower High pressure operation models Liquid filled pressure gauges CFM Model 50 75 100 150 200 280 380 630 850

10 to 300 Speed*1 [mm/s] 501 to 600 30 to 1200 20 to 850 10 to 300 Actuator specifications Parallel Stroke range Up to 500 20 to 900 12 to 600 6 to 300 24 to 800 16 to 650 8 to 325 30 to 750 20 to 550 10 to 300 501 to 600 30 to 750 20 to 550 10 to 300 Max. acceleration/deceleration [mm/s2] 3000 Positioning repeatability [mm] 0.01 (Lead H: 0.02) Lost motion [mm]*2 0.05 Lead [mm] 20 12 6 24

/1070 850/1070 1450/1890 2000/2500 Single-phase 200 V 4.3/4.7 4.3/4.7 Operating current [A] Refrigerant R407C (HFC) IDF F 50/60 Hz *6 Three-phase 200 V 3.3/3.5 3.3/3.5 6.0/6.6 7.2/8.0 Applicable earth leakage breaker capacity *7 [A] (Sensitivity of leak current of 30 mA) 10 (200 VAC) 15 (200 VAC) Condenser Air-cooled Refrigerant R407C (HFC) Refrigerant charge [kg] Single-phase 200 V 0.42

W: 800 [W] Power supply output VI: 1.0 [kVA] W Efficiency Q = P = Q = P = V x I x Power factor In this example, using an efficiency of 0.7: In this example, using a power factor of 0.85: 800 0.7 = 1.0 [kVA] x 0.85 = 0.85 [kW] = 850 [W] = = 1143 [W] Cooling capacity = Considering a safety factor of 20%, Cooling capacity = Considering a safety factor of 20%, 850 [W] x 1.2 = 1020 [W] 1143 [W

Power supply output VI: 1.0 [kVA] Q = P = V x I x Power factor In this example, using a power factor of 0.85: = 1.0 [kVA] x 0.85 = 0.85 [kW] = 850 [W] Cooling capacity = Considering a safety factor of 20%, 850 [W] x 1.2 = 1020 [W] HRZ W Efficiency Q = P = HRZD In this example, using an efficiency of 0.7: HRW 800 0.7 = = 1143 [W] HECR Cooling capacity = Considering a safety factor of 20%,

Nil Without cable H Without cable (Connector only) 1 1.5 Applicable Stroke Table : Standard Stroke [mm] Manufacturable 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 stroke range Model [mm] LEFS25 50 to 600 LEFS32 50 to 800 LEFS40 150 to 1000 * When the driver type is selected, the cable is included. Select cable type and cable length.