SMC Corporation of America
Elite Part Number Search
Search Results "KQG2T10-12-F"

Bore size (mm) 12 16 20 25 32 40 Distance between guide rods GP 50 65 80 90 110 130 GP > 0.5 Calculation of load ratio to the theoretical output of cylinder = f / F Horizontal mounting: f = x W Inclined mounting: f = x Wcos + Wsin (Refer to the figure on the right.)

x FD 2 x P (Rc, NPT, G) 4 x J Width across flats KA FB e E D d f 10.2 l C B + Stroke + Stroke Air release h + l ZZ + l + Stroke (mm) Stroke range (mm) A Bore size (mm) AL FB B B1 C D E F FV FD FT FX FY FZ G H1 J Without rod boot With rod boot 40 Up to 500 20 to 500 30 27 71 60 22 44 16 32 10 60 9 12 80 42 100 15 8 M8 x 1.25 50 20 to 600 Up to 600 35 32 81 70 27 52 20 40 10 70 9 12 90 50 110

Refer to pages starting with 181 for mounting. 95 100 8(4)-6.2 B 95 ( ) ( ) (170) A 95 110 20 95 ( ) ( ) (150) A B 100 200 300 400 500 600 700 800 900 1000 1200 Stroke Model LG1H212SC-100-F LG1H212SC-200-F LG1H212SC-300-F LG1H212SC-400-F LG1H212SC-500-F LG1H212SC-600-F LG1H212SC-700-F LG1H212SC-800-F LG1H212SC-900-F LG1H212SC-1000-F LG1H212SC-1200-F 80 180 280 380 480 580 680 780 880

E Size Width across hexagon socket hole B 8 12 16 20 M H1 F G H2 11 A1 A Metal Stopper with Bumper [mm] Model Adjuster part no.

(mm) Bore size A AL B1 CD CI CX D E F FL G H H1 I K KA L MM NA NN 20 18 15.5 13 8 20 12 8 20 0 0.033 13 10.5 8 41 5 28 5 6 12 M8 x 1.25 24 M20 x 1.5 25 22 19.5 17 8 22 12 10 26 0 0.033 13 10.5 8 45 6 33.5 5.5 8 12 M10 x 1.25 30 M26 x 1.5 32 22 19.5 17 10 27 20 12 26 0 0.033 13 10.5 8 45 6 37.5 5.5 10 15 M10 x 1.25 34.5 M26 x 1.5 40 24 21 22 10 33 20 14 32 0 0.039 16 13.5 11 50 8 46.5 7 12

) B1 C1 H1 L1 MM X 12 16 20 25 8 10 13 17 9 10 12 15 4 5 5 6 14 15.5 18.5 22.5 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 10.5 12 14 17.5 H1 X C1 L1 Standard (mm) A B Bore size (mm) O C D E E1 E2 F H I K L M N W 5st 25.5 27 29 32.5 10st 30.5 32 34 37.5 5st 22 23.5 24.5 27.5 10st 27 28.5 29.5 32.5 12 16 20 25 6 8 7 12 6 8 10 12 23 26 30 33 13 15 17 19.5 14 17 19 22 7 8.5 10.5 12 M3 x 0.5 M4 x

, 16 85 + 40 (n 4) 2 n = 4, 8, 12, 16 90 + 40 (n 4) 2 n = 4, 8, 12, 16 105 + 40 (n 4) 2 95 + 40 (n 4) 2 n = 4, 8, 12, 16 n n = 4, 8, 12, 16 2 (Different sides and same side) With 1 10 65 75 80 90 D-Y69/Y7PV D-Y7WV n 90 + 30 (n 4) 2 80 + 30 (n 4) 2 n = 4, 8, 12, 16 10 + 30 (n 2) 2 n = 2, 4, 6, 8 65 + 30 (n 4) 2 n = 4, 8, 12, 16 75 + 30 (n 4) 2 n = 4, 8, 12, 16 n = 4, 8, 12, 16 2 (

f h AM (JW) KK Dimensions [mm] Bore size AM BE C CD EE EW F G1 G2 H (HR) K KK KV KW NA ND RR S SW U WA (WH) (XC) Z ZZ 8 12 M12 x 1.25 4 4 M5 x 0.8 8 12 7 5 28 13.4 M4 x 0.7 19 6 15 12 10 46 7 6 16 64 76 86 10 12 M12 x 1.25 4 4 M5 x 0.8 8 12 7 (5.5) 5 (5.5) 28 14.2 M4 x 0.7 19 6 15 12 10 46 (53) 7 6 10.5 16 64 (71) 76 (83) 86 (93) 12 16 M16 x 1.5 6 6 M5 x 0.8 12 17 8 (5.5) 6 (5.5) 38 14.2

Flat with rib Flat type Flat with rib (mm) (mm) Model A ~ B C D IG:M5X O.8 1G:M6xl y ~ H:M6 x l H:M8'x'1 V , I .c F G .C F G Rat F Ot wilt i ib.: Model A > 8 .1 0 E E F E F Flat Flat with rib ZPT40g 40 43 1 ,85 ZPT1O~ 1 0 12 12 17 20 38 25 43 3 1.7 3 25 50.5 4.5 '5 40.5 65 3.3 24.5 , > ~ . :'z;p-rt:Jg ZPTsog 50 53 " 9.5 1 3 . 15, 12 17 .20 38 25 43 3 1.8 3 25 51.5 4$ '?

For DIN rail model number, refer to page 4-12-12.

Note 2) L kit: Nil F P PC J Nil S F kit P kit (26P) P kit (20P) J kit (20P) L kit S kit q w Note) L kit: Nil F e r kit SE SSQ1000 No.

[3][5] 00 16 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 1 0F ABS 10 11 80 12 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 1 8F ABS 90 91 14 13 14 (6) ([4][0]) [4][0] [0][1][F][F] (16)10 8 (7) ([5][0]) [5][0] [0][1][F][F] (16)10 8 (8) ([5][4]) [5][4] [0][1][F][F] (16)10 8 (9) ([5][8]) [5][8] [0][1][F][F] (16)10 8 (10)(DWELL)([6][0]) [6][0] [0][1][F][F] (DWELL) (16)

With air cushion GA WA GB WB 2 x P (Rc, NPT, G) Cushion valve, Width across flats WH W 10 With rod boot 8 8 8 IJ IJ e e JH f f l l JW ZZ + l + Stroke ZZ + l + Stroke h + l h + l 80, 100 (mm) Bore size Stroke range Rc, NPT port G port A AL B B1 C D E F FD FT FX H H1 I J K Standard Long stroke GA GB P GA GB P 20 Up to 200 201 to 1500 12 10 (12) 1/8 12 10 (12) M5 x 0.8 18 15.5 40 13 14 8 12

Bore size Body option 12 Note 1) 16 20 25 32 40 50 63 Port thread type 12 mm 16 mm 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm Nil Standard (Rod end female thread) With boss on head end M thread Rc NPT G 12 to 25 Nil F TN TF F With rubber bumper (12 with auto switch only) 32 to 63 C Note 1) When 12 with auto switch is required, the body option should be with rubber bumper (C).

3 12 12 12 12 HNBR HNBR Carbon steel Stainless steel Note) Purchasing order is available in units of 10 pieces. 2-4-229 Series VQ Exploded View: VQ0/Plug Lead Unit (F, P, C, S kit) Note 3) For how to increase the stations, refer to the instruction manual.

VQD AXT661-14A-F AXT661-14AN-F AXT661-13A-F AXT661-13AN-F Positive common Single (2-wire) Negative common Positive common Double (latching) (3-wire) Negative common Note) Lead wire length: 300 mm DIN Rail Mounting Each manifold can be mounted on a DIN rail. Order it by indicating an option symbol for DIN rail mounting style, -D.

Linearity (77F) 0.15% F .S. Repeatability (77F) 0.6% F .S. 0.5% F .S.

) 12 V 5 V, 12 V IC circuit Diagnosis (2-color indication) Grommet Yes Relay, PLC 3-wire (PNP) 24 V 2-wire 12 V 3-wire (NPN) 5 V, 12 V IC circuit Water resistant (2-color indication) 3-wire (PNP) 2-wire 12 V Auto switches marked with a symbol are produced upon receipt of order.

Description Frame length [6][4] [0][1] to [F][F] Auxiliary function read 8 The decimal equivalent of the data No. value (hexadecimal) corresponds to the Point table No. (12) Group setting (Command [1][F]) Command Data No. Description Frame length [1][F] [0][0] Reading of group setting value 4 (13) Test operation mode (Command [0][0]) Command Data No.

AMF150C AMF-EL150 AMF-EL150-F AMF250C AMF-EL250 AMF-EL250-F AMF350C AMF-EL350 AMF-EL350-F AMF550C AMF-EL550 AMF-EL550-F AMF650 AMF-EL650 AMF850 AMF-EL850 Except option F For option F Element assembly Glass fiber, others AMF-EL450 AMF-EL450-F 4 Industrial Filters Replacement Procedure Actuators Modular F.R.L.