SMC Corporation of America
Elite Part Number Search
Search Results "JMDBF63TN-400-W"

U N T I N G See NCJ2 Accessories Section A P P L I C A B L E A U T O S W I T C H B Basic D Double Clevis L Axial Foot F Rod Side Flange P O R T L O C AT I O N O N H E A D C O V E R B O R E/S T D S T R O K E(H U N D R E D T H S O F A N I N C H) R In-Line Perpendicular 10 (3/8) 050. 100. 150, 200, 300, 400, 500, 600 16 (5/8) 050, 100, 150, 200, 300, 400, 500, 600, 700, 800 T E C H N I C A L

[Horizontal] W SOL.C SOL.B SOL.A Regulator 2.

: 200/400 VAC Note 5) q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid temperature: 20C, r Load: Same as the cooling capacity, t Circulating fluid flow rate: Rated flow, y Power supply: 200/400 VAC, u Piping length: Shortest Note 6) With the pressure control mode by inverter.

Connect the driver power output (U/V/W) to the servo motor power input (U/V/W) directly. Do not let a magnetic contactor, etc. intervene. Otherwise, it may cause a malfunction. CAUTION Driver Driver Servo amplifier Servo motor Servo amplifier Servo motor U U U U V V M V M V W W W W 3 2 3.

220 200 V (50 Hz) 200, 220 V (60 Hz) IDF-TR4000-7 355 299 320 42 kg (mm) IDF-TR 8 C E G Specifications/Dimensions B A B C D E F G Mass Inlet voltage Outlet voltage IDF-TR7000-8 IDF-TR9000-8 IDF-TR14000-8 IDF-TR18000-8 Transformer Applicable dryer IDF120D IDF150D Capacity Type 360 400 400 400 11 13 13 13 30 40 40 40 7 kVA 9 kVA 14 kVA 18 kVA 540 650 650 650 400 450 450 450 260 300 300 300

Basic Foot Front flange W/o rod boot W/ rod boot S W/o rod boot W/ rod boot W/o rod boot W/ rod boot S Stroke range LS Stroke range 201 to 350 301 to 400 301 to 450 301 to 800 WB S Bore (mm) Bore (mm) Bore (mm) Stroke range 201 to 350 301 to 400 301 to 450 301 to 800 GB GB TB GB ZZ 206 223 226 250 ZZ ZZ 210 ZZ ZZ 206 223 226 250 ZZ 20 25 32 40 20 25 32 40 20 25 32 40 186 201 204 230 190 201

mm 176 mm HECR012-W2 HRCR010-A2 Air-cooled Air-cooled Water-cooled 200 W, 400 W, 510 W 800 W, 1 kW 800 W, 1.2 kW Mountable in a 19-inch rack Space can be saved by mounting multiple pieces of equipment together in a single rack.

Graph (1) 400 st 500 st 600 st 700 st 400 st 500 st 600 st 700 st 10 5 4 300 st 300 st 3 200 st 200 st Load movement time: t(S) 2 [Example] 100 st 100 st Example) 1 0.5 0.4 0.3 V' 0.2 V W 0.1 100 200 300 400 500 1000 Cylinder stroke Maximum speed: V (mm/s) Movement distance of load Find the bore size.

Graph (1) 400 st 500 st 600 st 700 st 400 st 500 st 600 st 700 st 10 5 4 300 st 300 st 3 200 st 200 st Load movement time: t(S) 2 [Example] Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 100 st 100 st Example) 1 0.5 0.4 0.3 V' 0.2 V W 0.1 100 200 300 400 500 1000

V(mm/s) LEFS16 LEFS25 LEFS32 Vertical Transfer 12 50 B B B 20 A 10 A A 40 H W(kg) W(kg) H 8 W(kg) 15 30 6 10 20 4 5 2 10 0 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0

Table Displacement (Reference Value) L W 0.02 LEJ40 (L = 52.5 mm) LEJ63 (L = 64.5 mm) Displacement [mm] 0.01 0 0 100 200 300 400 500 Load W [N] Note) This displacement is measured when a 15 mm aluminum plate is mounted and fixed on the table.

[mm] Bore size Standard stroke Max. manufacturable stroke Stroke range q Stroke range w 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Up to 1000 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 Up to 1200 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500,

Basic Foot Front flange W/o rod boot W/ rod boot S W/o rod boot W/ rod boot W/o rod boot W/ rod boot S Stroke range WB S Bore (mm) Bore (mm) Bore (mm) Stroke range 201 to 350 301 to 400 301 to 450 301 to 800 LS Stroke range 201 to 350 301 to 400 301 to 450 301 to 800 GB GB TB GB ZZ 210 ZZ ZZ 206 223 226 250 ZZ ZZ 206 223 226 250 ZZ 20 25 32 40 20 25 32 40 20 25 32 40 186 201 204 230 201 to

Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) Note 3) q Ambient temperature: 90F (32C), w Circulating fluid: Tap water, e Circulating fluid temperature: 68F (20C), r Circulating fluid flow rate: Rated flow, t Power supply: 200 VAC 9 Standard Type Thermo-chiller Water-cooled 400 V Type Series HRS100/150 RoHS How to Order 100 W 40 HRS Cooling

9 Carbon steel @0 How to Order Seal Kit NCA1 W 150 PS Option Option -XB5 Oversized rod -XB6 High temperature -XB7 Low temperature -XC11 Dual operation/Single rod Bore W K Single rod Double rod Non-rotating 150 200 250 325 400 Available for 150, 200 and 250 bores only. Use single rod designation when ordering XC11 kit. Note: XC10 seal kit order 2 single rod kits.

9 Carbon steel @0 How to Order Seal Kit NCA1 W 150 PS Option Option -XB5 Oversized rod -XB6 High temperature -XB7 Low temperature -XC11 Dual operation/Single rod Bore W K Single rod Double rod Non-rotating 150 200 250 325 400 Available for 150, 200 and 250 bores only. Use single rod designation when ordering XC11 kit. Note: XC10 seal kit order 2 single rod kits.