Series: JSY1000, Type: Side Ported, Valve Stations: 10 Stations, P,E Port Entry: Both Sides, A,B Port Size: ø4 One-touch Fitting; Fixed, Thread Size: -, Mounting: -, DIN Rail Option: -
28.4 6 14 1/4 KQ2Y10-02lS 17 15.9 17 20.6 28.6 20.6 44.6 15.6 40 28.4 7.5 24.5 3/8 KQ2Y10-03lS 17 15.9 17 20.6 29.5 20.6 45.1 15.6 40 28.4 7.5 25 1/2 KQ2Y10-04lS 22 15.9 17 20.6 33.5 20.6 47.8 15.6 40 28.4 7.5 47.4 H 10 Connection thread (With sealant) 12 1/4 KQ2Y12-02lS 17 18.5 17 23 29.9 23 48.3 17 57.4 45.4 9 27.6 3/8 KQ2Y12-03lS 17 18.5 17 23 30.8 23 48.8 17 57.4 45.4 9 28.2 1/2 KQ2Y12
28.4 6 14 1/4 KQ2Y10-02GS 17 15.9 15.6 17 20.6 28.6 20.6 44.6 15.6 40 28.4 7.5 24.5 3/8 KQ2Y10-03GS 17 15.9 15.6 17 20.6 29.5 20.6 45.1 15.6 40 28.4 7.5 25 1/2 KQ2Y10-04GS 22 15.9 15.6 17 20.6 33.5 20.6 47.8 15.6 40 28.4 7.5 47.4 Connection thread (With sealant) 10 Release button dimensions 12 1/4 KQ2Y12-02GS 17 18.5 18.2 17 23 29.9 23 48.3 17 57.4 45.4 9 27.6 3/8 KQ2Y12-03GS 17 18.5
4BFlange 20 2BFlange 30 3BFlange 40 4BFlange Shape Piping support style Standing style 60 6BFlange How to Select Max.
4B flange 20 2B flange 30 3B flange 40 4B flange Vessel shape Piping support type Self-standing type 60 6B flange Model Selection Max.
4BFlange 40 4BFlange 60 6BFlange Style Style 00 With manual drain cock With manual drain cock 10 With auto drain With auto drain 01 11 How to Select Max.
4B flange 40 4B flange 60 6B flange Type Type 00 With manual drain cock 10 With auto-drain 01 With manual drain cock 11 With auto-drain Max.
Low Maintenance Filter Low Maintenance Filter Series FN1/FN4 Series FN1/FN4 New Series FN4 FN4 Series FN1 FN1 Series FN4 Series FN1 Series FN4 FN4 Series FN1 FN1 Flow rate max. 250 l/min max. 80 l/min max. 40 l/min Series FN4 with four elements is added!
Series: 1 (JSY1000), Type: 40 (Side Ported), Stations: 2 Stations, P.E. Port Entry: B (Both Sides), A.B. Port Size: C4 (ø4 One-touch Fitting; Fixed), Thread Size: Rc
Series: JSY1000, Type: Side Ported, Stations: 2 Stations, P.E. Port Entry: Both Sides, A.B. Port Size: ø4 One-touch Fitting; Fixed, Thread Size: Rc
3) Exhaust throttle SQ Series 38 1 4 1 8 M5 38 1 2 1 2 1 4 1 8 M5 VFS Bracket C4 C6 C8 C10 C12 N3 N7 N9 N11 VFR VQ7 SY3 20 SY5 20 SY7 20 External Pilot (Note 2) External Pilot (Note 2) External Pilot (Note 2) DIN terminal (EA, EB) (P) M8 connector SY9 20 SY3 40 SY5 40 SY7 40 External pilot Sub-plate External pilot External pilot DIN terminal M8 connector SY9 40 Standard Option Made to order
M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 10-SS5YJ3-32-M5 10-SS5YJ3-32-C4 10-SYJ333 1/8 10-SS5YJ3-S32-M5 10-SS5YJ3-S32-C4 Base mounted for internal pilot 10-SS5YJ3-41-M5 10-SS5YJ3-41-C4 10-SYJ343 1/8 10-SS5YJ3-S41-M5 10-SS5YJ3-S41-C4 10-SS5YJ3-46-M5 1/8 M5 x 0.8 10-SS5YJ3-46-C4 10-SYJ343 10-SS5YJ3-S46-M5 10-SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position
SS5Y31, #3 + #15 8 Body Ported Type Note) [ ]: Values for AC < >: Values with surge voltage suppressor Series SY5000 Dimensions With foot bracket SY5120-F1 2 position single Grommet (G), (H): SY5120(-F2) Scale: 40% G H C4 C6 C8 G H C4 C6 C8 G H SY5120-01 L type plug connector (L): SY5120-LDIN terminal (D): SY5120-DC4 C6 C8 M type plug connector (M): SY5120-MC4 C6 C8 C4 C6 C8 Applicable cable
SY5000 Dimensions Note)< >: Values with surge voltage suppressor With foot bracket SY5120-F1-Q 2 position single Grommet (G), (H): SY5120(-F2)-Q Scale: 40% G H C4 C6 C8 G H C4 C6 C8 G H SY5120-01-Q L type plug connector (L): SY5120-L-Q DIN terminal (D): SY5120-D-Q C4 C6 C8 M type plug connector (M): SY5120-M-Q C4 C6 C8 C4 C6 C8 Applicable cable O.D. 3.5 to 7 59.2 51.7 Max.10 104.9 40.4 Pg
How to Order Valves (Type 45F, 45P, 45T, 45T1) A, B port size (Metric size) 5 LOZ SX 3 2 40 Symbol Port size Applicable series One-touch fitting for 4 C4 Series One-touch fitting for 6 C6 SX3000 3 SX3000 5 SX5000 Mixed M One-touch fitting for 4 C4 One-touch fitting for 6 C6 One-touch fitting for 8 C8 Mixed M SX5000 Type of actuation 1 2 position single 2 2 position double (Inch size) 3 3
, C6 C4: One-touch fitting for 4 C6: One-touch fitting for 6 2-C4, C6 C4: One-touch fitting for 4 C6: One-touch fitting for 6 4.5 4.5 M3 mounting hole M2.5 mounting hole Residual pressure release manual override DIN rail clamp screw 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread D side U side Stations 1 2 3 Dimensions
M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 M5 x 0.8 C4 10-SS5YJ3-32-M5 10-SS5YJ3-32-C4 10-SYJ333 1/8 10-SS5YJ3-S32-M5 10-SS5YJ3-S32-C4 Base mounted for internal pilot 10-SS5YJ3-41-M5 10-SS5YJ3-41-C4 10-SYJ343 1/8 10-SS5YJ3-S41-M5 10-SS5YJ3-S41-C4 10-SS5YJ3-46-M5 1/8 M5 x 0.8 10-SS5YJ3-46-C4 10-SYJ343 10-SS5YJ3-S46-M5 10-SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position
pilot port) (Lead wire length) Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors 75.4 [82.4] 34.5 17.5 15.5 96.5 44.5 29.5 29.5 3/8, 1/2 [1(P), 5(EA), 3(EB) port] L plug connector (L): 10-SY9 40(R)-LM plug connector (M): DIN terminal (D, Y): 10-SY9 40(R)-WO3 4 5 M8 connector (WO): 3 4 5 3 4 5 3 4 5 D Y 10-SY9 40(R)10-SY9 40(R)