3 2 B 2 B 2 B 2 B 2 B PCI BUS IN BUS OUT 8 7 1 2 3 4 5 Valve stations For N, sizes are in inches.
Thread: Rc, Port: 2 [1/4", (1000, 2000)], Stations: 2 Stations, Pressure: 2050 (0.9 MPa), Protocol: SEN (Ethernet I/Pâ„¢)
Thread: Rc, Port: 2 [1/4", (1000, 2000)], Stations: 2 Stations, Pressure: 2010 (0.1 MPa), Protocol: SEN (Ethernet I/Pâ„¢)
Thread: Rc, Port: 2 [1/4", (1000, 2000)], Stations: 2 Stations, Pressure: 0.9 MPa, Protocol: Ethernet I/Pâ„¢
Thread: Rc, Port: 2 [1/4", (1000, 2000)], Stations: 2 Stations, Pressure: 0.1 MPa, Protocol: Ethernet I/Pâ„¢
-SDN1(-X2/-X26/-X77) -43No.EX-OME0015-F EX122-SDN1(-X2/-X26/-X77) EX124D-SDN1(-X2/-X26/-X77) -44No.EX-OME0015-F EX124U-SDN1(-X2/-X26/-X77) -45No.EX-OME0015-F Accesary Waterproof cap Use for unused conduit port (G1/2) when using EX124 Series.
NA-080-INFLW 97 Power 73 54 30 15 Alarm 2 x 6 Mounting Holes Tube O.D. 1/4 In Port Alarm 50 73 54 30 15 Tube O.D. 1/4 Out Port 4 x M4 x 4 Mounting Holes LLD2A-02-Z07-X31 4 x M4 x 4 Mounting Holes (Includes controller & connectors) 20 Indicator 96 13 30 40 50 20 73 115.5 1/4HyperFlare with flow to 3000 ml/min 1/4HyperFlare 3/8Soundpipe 2000 2000 Minimum flow 2 ml/min 35 35 Measurement Range
Example of unit number -16No.EX-OML0011-C 2.
JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
Body Size: 20 (1500 L/min), Pressure Range: 10 (0.005~0.1Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000), Made to Order: X26 (Manifold Mounting)
Body Size: 20 (1500 L/min), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000), Made to Order: X26 (Manifold Mounting)
Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: 0.005~0.1Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: Manifold Mounting
Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: Manifold Mounting
Body Size: 20 (1500 L/min), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)
Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: 0.005~0.5Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: -
Of the 2 rightmost DIP switches, the second switch is enabled for terminating resistor setting.
② The set pressure is transmitted to the regulator according to the setting of the master PLC, such as by hexadecimal (HEX).
Output data Index Sub Index Bit 15 8 Bit 7 0 Access 2065h 00h DYB, OUT 0 7 (Slot 3) RW1 2066h 00h SPL1-X26, OUT 0 15 (Slot4) RW 2067h 00h SPL1-X26, OUT 16 31 (Slot4) RW : : : 2084h 00h RW *1: "RW" mean that Read and Write are possible. 33 EX## OMS1015-A [Example 2] Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 AMB DMF DXF DYF SPL1-X26 Analog Digital Digital Digital SI unit End plate Valve input input
Note: EX600-SEN1/2 does not have L/A (LINK ACT) installed.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Operation Manual, N, ITV, "REGULATOR, N lb