SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-F02-AB-A"

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: 0 to 1.6 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

(%): 35~85, Number of Inputs: 1, Number of Outputs: 2, Power Supply Type: DC, Power Supply Voltage(V): [12 to 24] 12 to 24 ±10%, Liquid contact parts material: Resin + Metal, Display: Digital, Drive Component: Digital, Lamp: Presence, Acquired Standards: CE, Protection Structure: IP67, Unit Specifications: With unit conversion function, Bracket: None, Calibration Certificate included: N/A,

Piping: G1/4, ISO1179, Output: 43 [NPN Open Collector 1 Output (Pin No.:4)+PNP Open Collector 1 Output (Pin no.:2)], Display Unit: -, Option 1: -, Option 2: -