1 2 3 Signal Cable color U V W Red White Black Connector A2 terminal no.
Thin rectangular plate (cuboid) Position of rotation shaft: Passes through the center of gravity of a plate. a1 a a1 a2 b Step Motor (Servo/24 VDC) a2 a = m1 + m2 3 a12 3 a22 = m 12 a2 = m 12 a2 = m1 12 4a12 + b2 12 4a22 + b2 + m2 5. Thin rectangular plate (cuboid) Position of the rotation shaft: Passes through the center of gravity of the plate and perpendicular to the plate.
Principal Parts Material Body C3604BD, Flame resistant PBT (UL-94 standard V-0) C3604BD (Thread portion) Stainless steel 304 Stainless steel 304, Flame resistant PBT (UL-94 standard V-0) POM Stud Chuck Guide Collet Release button Seal, O-ring Flame resistant PBT, Flame resistant CR (UL-94 standard V-0) Cover (Option) Flame resistant PBT (UL-94 standard V-0) NBR 15-3-1 2 Series KR Model Male
L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/10 = 0.03 [s], T3 = V/a2 = 300/10 = 0.03 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be found by the following equation.
The angle is 69 when any of the following auto switches are used: D-S99(V), D-T99(V), and D-S9P(V) 3.
12 V Relay, PLC Yes Yes No Grommet 24 V IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 12 V IC circuit 3-wire (NPN equivalent) A96V A96 5 V 24 V Grommet A93V A90V A93 A90 Relay, PLC 100 V 2-wire 12 V IC circuit 100 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches
, PLC 2-wire IC circuit 5 V, 12 V 12 V 100 V or less 24 V Connector IC circuit 5 V, 12 V Solid state auto switches marked with are produced upon receipt of order.
T1 T2 T3 T4 L 0.5 V (T1 + T3) V T2 = L : Stroke [mm] (Operating condition) V : Speed [mm/s] (Operating condition) a1: Acceleration [mm/s2] (Operating condition) a2: Deceleration [mm/s2] (Operating condition) 500 0.5 300 (0.1 + 0.1) 300 T1 = V/a1 [s] T3 = V/a2 [s] = P T2: Constant speed time can be found from the following equation. = 1.57 [s] T4 = 0.3 [s] T2 = [s] L 0.5 V (T1
(The above graph shows the value when V port is 8.) Port size Flow rate characteristics of V to PV (Vacuum side) PV port V port C[dm3/(sbar)] b Cv 6 8 0.39 0.14 0.09 11.3. Vacuum Release Flow Rate Characteristics The graph shows the flow rate characteristics at different supply pressures when the vacuum break flow adjusting needle is open from the fully closed state.
Time [s] LEC SS-T T1 T2 T3 T4 T1 = V/a1 [s] T3 = V/a2 [s] LEC Y T2: Constant speed time can be found from the following equation.
(The above graph shows the value when V port is 8.) Port size Flow rate characteristics of V to PV (Vacuum side) PV port V port C[dm3/(sbar)] b Cv 6 8 0.39 0.14 0.09 11.3. Vacuum Release Flow Rate Characteristics The graph shows the flow rate characteristics at different supply pressures when the vacuum break flow adjusting needle is open from the fully closed state.
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
LED Indication SF BF L/A1 L/A2 PWR PWR(V) LED Indication Content Colour SF System fault Red/Orange BF Bus fault Red L/A1 Connection status of BUS IN/Port1 Green/Orange L/A2 Connection status of BUS OUT/Port2 Green/Orange PWR Power supply for logic/sensors (PWR) Green PWR(V) Power supply for valves (PWR(V)) Green Fig. 7-1 LED Indicators of the SI Unit 7.1.1.
V V V N7 1/4" V V V V V N9 5/16" V V V V N11 3/8" V V 2 V C3 3.2 V C4 4 V V V C6 6 V V V V V C8 8 V V V V C10 10 V V C12 12 V V Straight Straight D-sub, Flat Ribbon CM*1 Straight port, mixed sizes V V V V V LN3 5/32" V LN7 1/4" V V LN9 5/16" V Terminal Block Upward CM*1 Straight port, mixed sizes V V V V V L4 Lead Wire 4 V V L6 6 V V V L8 8 V V L10 10 V L12 12 V
Common Adjuster Options Model Stroke 10 20 30 40 50 75 100 125 150 MXQ6(L)-Zmm(6, 7, 8, 9) v v v v v MXQ8(L)-Zmm(6, 7, 8, 9) v v v v v v MXQ12(L)-Zmm(6, 7, 8, 9) v v v v v v v MXQ16-Zmm(6, 7, 8, 9) u v v v v v v v MXQ20-Zmm(6, 7, 8, 9) u v v v v v v v v MXQ25-Zmm(6, 7, 8, 9) v v v v v v v v v MXQ6A, 8A, 12A 10, 20 mm stroke Auto switch is not mountable End plate Adjustment block MXQ16(A)
Data
state auto switch Reed auto switch Terminal conduit 24 V Relay, PLC IC circuit Yes 5 V, 12 V Diagnostic indication (2-color) 12 V Grommet Water resistant (2-color indicator) 5 V, 12 V 12 V 3-wire (NPN equivalent) IC circuit A96 5 V Yes Grommet A93 A90 A33 A34 A44 100 V 100 V or less Relay, PLC No 2-wire IC circuit PLC 12 V 24 V Terminal conduit Yes Relay, PLC 100 V, 200 V Din terminal
Maximum current rating Voltage without load (V peak) 5.0 0 to 20 [V] 100 Peak voltage Over 20 [V] up to 30 [V] (2) Circuit (of class 2) which is of maximum 30 Vrms (42.4 V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. Grounding Warning 1. Make sure the product is grounded to ensure the noise tolerance of the controller.
A6) M3 x 0.5 v (uConnection thread: A5/A6) Female thread Nil v (uConnection thread: A8) B5 M5 x 0.8 v v B6 M6 x 1 v v v B8 M8 x 1.25 v v B01 Rc1/8 v v v N01 NPT1/8 v v v T01 NPTF1/8 v v v M5 x 0.8 v (uConnection thread: A8) 04 4 vV vV 06 6 vV vV vV 08 8 V vV Female thread One-touch fitting N4 For 4 nylon tubing1 N6 For 6 nylon tubing1 v v v U4 For 4 soft tubing2 U6 For 6 soft tubing2