Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A), Operation Manual: K (Operation
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -
T D2 L1 D2 L1 L2 L2 Metric Size A (2) M1 L5 (1) Mass (g) d T Model D2 D3 H D1 L1 L3 L4 L2 Min.
2 i r i t y w w e !0 !0 !2 !5 o !0 !4 q q y u !1 !3 r t !1 M5 type U10/32 type M5 type U10/32 type !1 y !2 u !4 !3 i !5 u e r r t w e o !0 i o q q t y !0 !2 w !
AS1001F-23D-X214 AS AS-FE KE AS-FG AS-FP AS-FM AS-D AS-T AS-D AS-T ASP ASN AQ ASV AK VCHC ASS ASR ASQ 591
(inch) Connection thread NPT T (UNF) Width across flat M Weight (g) Mounting hole L1 L2 Model H1 17 17 17 19 21 H2 14 14 17 19 22 Applicable tube KQG2E01-N02 KQG2E03-N02 KQG2E07-N02 KQG2E09-N03 KQG2E11-N03 KQG2E13-N03 KQG2E13-N04 3.4 5.6 13.1 26.1 41.5 1/4 1/4 1/4 3/8 3/8 3/8 1/2 12.5 12.5 14 17 20.5 12 12.6 13.5 16.1 16.6 32.8 32.6 32.7 35 33.8 34.6 41.4 15.3 15.3 14.8 15.1 13.3 12.3 19.1