Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Options: 6PZ (6 + P + Z), -A: -A
Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Options: 6PZ (6 + P + Z), -A: -A
Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Options: 6PZ (6 + P + Z), -A: -A
Size: 20, Thread: N (NPT), Port Size: 03 (3/8), Options: 6PZ (6 + P + Z), -A: -A
Thread: R, Seal: S (Seal), Options: 6PZ (6 + P + Z)
Thread: N (NPT), Seal: S (Seal), Options: 6PZ (6 + P + Z)
Thread: R, Seal: None, Options: 6PZ (6 + P + Z)
Thread: N (NPT), Seal: None, Options: 6PZ (6 + P + Z)
Also available are the IS10M (pressure switch with spacer) and the IS10E (pressure switch with piping adapter).Weight: 62g (16% lighter than IS1000), Overall height: 52mm (11% smaller than IS1000), 100V AC/DC specifications, Service life: 5 million cycles, Can be connected to modular type FRL units, RoHS compliant & CE marked, PRESSURE SW AC50/60 ONLY *LQA, INSTRUMENTATION, IS/NIS PRESSURE
Also available are the IS10M (pressure switch with spacer) and the IS10E (pressure switch with piping adapter).For connecting to modular type FRL units , 100V AC/DC specifications , Service life: 5 million cycles , RoHS compliant & CE marked, PRESSURE SWITCH, PRESSURE SWITCH, IS ISG, 821, 250 lb
The standard IS10M pressure switch cannot be set to 0.4 to 0.45 MPa because 0.4 MPa is the upper limit of the set pressure range.
For AC-A/AC-B series modular F.R.L units with a white body, the pressure switch must be replaced with an IS10M-□-6-A pressure switch (set pressure: 0.1 to 0.6 MPa).
Size: 60, Options: L (3m Lead Wire Length)
Size: 60, Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Size: 60, Options: P (Scale Plate Pressure Unit: Both MPa and psi)
Size: 60, Options: Z (5m Lead Wire Length)