SMC Corporation of America
Elite Part Number Search
Search Results "IP8000-030-BF"

Type: Relay Device, Type: Electro-pneumatic lever type, Option: None, Pressure(MPa): 1.0, Terminal box: N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: With Stroke 35 to 100 mm / lever unit, Compensation spring: N/A, External scale plate: N/A, Position feedback signal: N/A, Air connection port: Rc1/4, Conduit connection port: G1/2, Explosion-proof structure: Standard

Type: Relay Device, Type: Electro-pneumatic lever type, Option: None, Pressure(MPa): 1.0, Terminal box: N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: With Stroke 50 to 140 mm / lever unit, Compensation spring: N/A, External scale plate: N/A, Position feedback signal: N/A, Air connection port: Rc1/4, Conduit connection port: G1/2, Explosion-proof structure: Standard

Type: Relay Device, Type: Electro-pneumatic lever type, Option: None, Pressure(MPa): 1.0, Terminal box: N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: N/A, Compensation spring: N/A, External scale plate: N/A, Position feedback signal: N/A, Air connection port: Rc1/4, Conduit connection port: 1/2NPT, Explosion-proof structure: Standard product, CE compatible: CE-non-compliant

Type: Relay Device, Type: Electro-pneumatic lever type, Option: None, Pressure(MPa): 1.0, Terminal box: N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: N/A, Compensation spring: N/A, External scale plate: N/A, Position feedback signal: N/A, Air connection port: Rc1/4, Conduit connection port: G1/2, Explosion-proof structure: Standard product, CE compatible: CE-compliant product

Type: Relay Device, Type: Electro-pneumatic lever type, Option: None, Pressure(MPa): 1.0, Terminal box: N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: N/A, Compensation spring: N/A, External scale plate: N/A, Position feedback signal: N/A, Air connection port: 1/4NPT, Conduit connection port: M20 × 1.5, Explosion-proof structure: ATEX Directive Category 2 Intrinsically safe

Type: 000 (Lever Type Feedback), Pressure Gauge: 3 (1.0MPa), Construction: 0 (No Terminal Box), Accessories: F (For Stroke 50 to 140mm w/Lever Unit), Connection: 3 (1/4NPT, 1/2NPT)

IP8000 E/P positioner is more compact than the IP6000 with improved visibility of the pressure indicator.  Other features include an improved enclosure protection IP65, interchangeable mounting, excellent shock and vibration performance, and a 1/2 split range available by simple span adjustment.  The IP200 cylinder positioner provides accurate and stable positioning of air cylinders.  

Type: Lever Type Feedback, Pressure Gauge: 1.0MPa, Construction: No Terminal Box, Accessories: For Stroke 50 to 140mm w/Lever Unit, Connection: 1/4NPT, 1/2NPT

Type: Relay Device, Type: Electro-pneumatic lever type, Option: None, Pressure(MPa): 1.0, Terminal box: N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: N/A, Compensation spring: N/A, External scale plate: N/A, Position feedback signal: N/A, Air connection port: 1/4NPT, Conduit connection port: 1/2NPT, Explosion-proof structure: Standard product, CE compatible: CE-compliant

Type: Relay Device, Type: Electro-pneumatic lever type, Option: None, Pressure(MPa): 1.0, Terminal box: N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: With Stroke 35 to 100 mm / lever unit, Compensation spring: N/A, External scale plate: N/A, Position feedback signal: N/A, Air connection port: 1/4NPT, Conduit connection port: M20 × 1.5, Explosion-proof structure: ATEX

Type: Relay Device, Type: Electro-pneumatic lever type, Option: None, Pressure(MPa): 1.0, Terminal box: N/A, Pilot valve: N/A, Fork lever type fitting: N/A, Lever unit: With Stroke 50 to 140 mm / lever unit, Compensation spring: N/A, External scale plate: N/A, Position feedback signal: N/A, Air connection port: 1/4NPT, Conduit connection port: M20 × 1.5, Explosion-proof structure: ATEX

SF LED/BF LED . 6-3 SF LED/BF LED SF BF OFF OFF SI (IO ) US1 (DC19.2 V ) ON --IO Device name IP GSD IO --ON (1Hz) SI FW SI Web SF ON SF OFF BF OFF BF ON (1Hz) SI FW SF ON SF OFF BF ON BF OFF 6.4.2. US1 LED . 6-4 US1 LED US1 OFF US1 OFF (1 Hz) US1 ON (DC19.2 V ) ON US1 ON 6.4.3. US2 LED . 6-5 US2 LED US2 OFF US2 OFF ON US2 ON 41 No.EX-OMW0014CN-A 6.4.4.

During forced output mode by Web server function. at 1 Hz SF ON SF OFF BF OFF BF ON Simultaneously flash at 1 Hz Firmware update failed. SF ON SF OFF BF ON BF OFF 6.4.2. US1 indicator Table. 6-4 US1 indicator US1 Meaning OFF US1 is not present. Flash at 1 Hz US1 is present but is below the permissible level (< approx. 19.2 VDC). ON US1 is present. 6.4.3.

SF BF: () (PLC) LED 27 PROFIBUS DP SF: BF PROFIBUS DP 11 SF BF SI 0126 1~125 SF BF PLC SF: BF SI PLC V_SEL PLC SI PWR LED DC24 V+10/-5 SI ~ SI 12 SI EX600-SPR1A (PNP ) EX600-SPR2A (NPN ) SI SI -49No.EX-OMN0027CN-D No. (PNPNPN) SI PWR LED DC24 V10% 13 (PNPNPN) SI PWR LED DC24 V+10/-5 PLC -50No.EX-OMN0027CN-D No.

Red BF LED is ON The address of the SI unit is set to 0, or to 126 or over. Red BF and SF LEDs are both ON The configuration data of the master and device are not consistent. Red SF LED is ON and red BF LED is flashing The SI unit has recognized the communication speed, but the address setting of the master is incorrect.

ZE ZD ZJ VA depth VB WC depth WD AH AG AJ (AF) BF AH AF MHSHJ3-32DB, 40DB Note) For dimensions, refer to the MHSHJ3-32 to 80D dimensions on page 580.

BG BE ZE ZD MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VA depth VB ZJ MHS MHC WC depth WD AH ZH, thread depth ZI AG AJ (AF) MHT MHY MHW BG BF MRHQ Misc.

BF OFF PROFINET connection is established. Refer to 7 LED display (P.29) for the explanation of the LEDs. Communication between PLC and controller is not established when the BF red LED is on or is flashing red. Caution Communication between PLC and controller is not established. Refer to 19.

SI unit Refer to fault SI unit PWR LED is OFF malfunction No.1 SI unit Refer to fault PWR (V) LED is OFF No.2 Yes No SI unit SI unit Refer to fault SF LED is ON BF LED is ON No.3 Refer to fault No.4 SI unit SI unit Refer to fault BF LED is flashing SF LED is ON No.5 Refer to fault No.6 Group of valves Refer to fault not working No.7 All valves and Refer to fault valve LEDs are not operating

d D e H1 AL A T 8 f l K lC ZZ + l + Stroke h + l FT BN N lB H M S + Stroke ZZ + Stroke Long stroke (50 to 100) 4-FD d RY FY BF e 8 f l ZZ + Stroke Z FT RT FZ FX ZZ + l + Stroke h + l (mm) Bore (mm) Stroke range (mm) A AL B B1 BF BN BP BQ C D E FD FT FV FX FY FZ GA GB GC GD GL GL1 GR H1 J 40 50 63 80 100 30 27 60 22 71 96 1/8 1/8 44 16 32 9 12 60 80 42 100 85 15 52 16 12 12 10 8 M8 X 1.25