40 e Valve Model Fill in the blanks below with symbols of necessary specifications.
Applicable cylinder bore size (mm) Model Metric size Inch size ASP 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS1001F 6, 10, 16, 20 ASN AS2001F 20, 25, 32 AS2051F 20, 25, 32, 40 AQ AS3001F 40, 50, 63 ASV AS4001F 63, 80, 100 AK Flow Rate and Effective Area ASS AS1001F AS2001F AS3001F AS2051F AS4001F Model JIS Symbol Metric size 6 6 8 10 6 8 3.2, 4, 6 4 10, 12 12 ASR Tubing O.D.
ASV AK Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
This product cannot be used to hold a stop position for an extended period of time. Pilot check valves and actuators are not guaranteed for zero air leakage. Therefore, it is sometimes not possible to hold a stop position for an extended period of time. In the event that holding for an extended time is necessary, a mechanical means for holding should be devised. 3.
Cooling Capacity: 200 (20.5kW), Thread: Rc, Option: AK (A + K)
Cooling Capacity: 200 (20.6kW), Thread: F (G, w/Rc-G Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 200 (20.6kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 20.5kW, Thread: Rc, Option: A + K
Cooling Capacity: 20.6kW, Thread: G, w/Rc-G Conversion Fitting, Option: A + K
Cooling Capacity: 20.6kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Data View A-A Mounting dimensions Bore size (mm) Stroke range (mm) N M L K J I B AP AO AN AM AL AK AJ AI AH AG AB AA A 20 25 32 40 50 75, 100, 125, 150, 200 25 38 80 60 44 25 106 22 M6 110 55 9 6.6 90 75 120 105 13 11 84 32 46 95 70 52 30 120 27 M8 125 65 9 9 100 84 136 120 13 15 89 75, 100 125, 150 200, 250 300 32 50 105 80 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 38 60 125 95
AK ASS ASR Straight type Easily installed in pipe lines.
D-G5NBL 5 35 5 40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.
D-G5NBL 5 35 5 40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.
AS1001FG-04-X214 ASV AK Needle Valve/Flow Characteristics VCHC Note) The flow characteristics are representative values.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size Flat head screwdriver 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80,
This product cannot be used to hold a stop position for an extended period of time. Pilot check valves and actuators are not guaranteed for zero air leakage. Therefore, it is sometimes not possible to hold a stop position for an extended period of time. In the event that holding for an extended time is necessary, a mechanical means for holding should be devised. 3.
Applicable cylinder bore size (mm) Model Metric size Inch size ASP 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS1001F 6, 10, 16, 20 ASN AS2001F 20, 25, 32 AS2051F 20, 25, 32, 40 AQ AS3001F 40, 50, 63 ASV AS4001F 63, 80, 100 AK Flow Rate and Effective Area ASS AS1001F AS2001F AS3001F AS2051F AS4001F Model JIS Symbol Metric size 6 6 8 10 6 8 3.2, 4, 6 4 10, 12 12 ASR Tubing O.D.
Use an extension fitting included with the product for the combinations in the table below.
Cooling Capacity: 200 (20.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: K (w/Fluid Fill Port)