mm Lead 150 Slide screw 20 mm Lead 500 10 mm Lead Ball screw Horizontal specification Maximum speed 1000 600 500 930 740 20 mm Lead 100W mm/s 500 Slide screw 20 mm Lead 180 10 mm Lead Ball screw 100W Nm Rated thrust 90 20 mm Lead 50 Slide screw 20 mm Lead Rolled 0.05 Repeatable positioning accuracy Ball screw Ground 0.02 mm 0.1 Rolled Slide screw Motor output Horizontal specification
Do not supply 24 VDC power supply continuously to the [BK RLS (Lock release)] terminal. Stop supplying 24 VDC power supply to the [BK RLS (Lock release) terminal during normal operation. If power is supplied to the [BK RLS] terminal continuously, the lock will be released, and workpieces may be dropped when the stop signal (EMG) is received. 9.
10 5 16 8 4 20 10 5 2.86 Impact resistance/vibration Resistance [m/s2] Note5) 50 / 20 50 / 20 50 / 20 Ball screw Drive method Ball screw and Belt [1:1] / Ball screw Ball screw and Belt [1.25:1] Ball screw Ball screw and Belt [4:7] Guide type Sliding bush (Piston rod part) Sliding bush (Piston rod part) Sliding bush (Piston rod part) Operating temperature range [] 5 to 40 5 to 40 5 to 40
Electric actuator / Slider type Specific precautions . 20 3.1 Design . 20 3.2 Slection . 20 3.3 Handling . 20 3.4 Precaution on maintenance . 22 4. Troubleshooting . 22 -1- LEJ series / Slider type Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Electric actuators / Common precautions 19 9.1 Design and selection 19 9.2 Mounting 20 9.3 Precautions for Use 20 9.4 Operating environment 21 9.5 Maintenance 22 9.6 Precautions for electric actuator with lock 23 10.
Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH150-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb
Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH150-W-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb
S1CBL M-A1-H MR -BK S1CBL M-A 2 H MR-BKS2CBL03M-A1-L MR -BK S2CBL 03 M-A 2 L ( ) AWG 20 B1 AWG 20 B2 . 13 9 13 13.2 (1) [W] LEC-MR-RB-032 LEC-MR-RB-12 [40] [40] LECSC-S5 30 LECSC-S7 10 30 100 LECSC-S8 10 30 100 (2) (2) PA02 PA02 0 0 00 100W 200W / 400W 02 LEC-MR-RB-032 03 LEC-MR-RB-12 13 10 13 (3) 13.4 100 5m (a) LECSCP-DP-CG3G4 G3-G4 P-D P-D 1 P P C C G3 D (2) 1) G4 5m
byte 3 12 byte 4 byte 4 10 byte 5 20 byte 6 20 byte 4 byte 7 10 byte 8 20 byte 9 36 byte 4 byte 10 10 byte 11 20 byte 125 Get/Set 2 JOG *1 IO 20 - 3IO IO Number Type Name 100 Input 101 Input 102 Input 14 110 Output 111 Output 112 Output 12 113 Output 4IO Input Assembly Instance Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 OUT5 OUT4 OUT3 OUT2 OUT1 OUT0 1 ALARM ESTOP
RLS (3) EMG LK RLS (6) (2) M 24V (1) C 24V 0V (4) DC24V 0V (1)(DC24V) (2)BK RLS (3)BK RLS -26- 6.4 (1)() (3m) SI PWR (3) EMG (2) M 24V (1) C 24V 0V (4) DC24V 0V -27- (2)((1)) DC24V EMG () DC24V 0V Ry Ry: U LK RLS (6) Ry (1 ) (3) EMG (2) M 24V (1) C 24V 0V (4) DC24V 0V LK RLS (6) Ry (2 ) (3) EMG (2) M 24V (1) C 24V 0V (4) DC24V 0V LK RLS (6) Ry (3 ) (3) EMG (2) M
6.1 . 20 6.2 . 20 6.3 . 21 1 - . 22 7.CN3 . 23 8.CN1IF(CONT) . 24 8.1 . 24 8.2 . 26 9.CN2TB/PC . 27 9.1 . 27 10.LED . 28 10.1 LED . 28 10.2IFLED . 28 11. . 29 11.1 . 29 11.2 . 29 11.3 . 29 11.4 . 31 12. . 32 12.1 . 32 12.2 IF(IN Data) . 38 12.3 (IN Data) . 38 12.4(OUT Data) . 40 13.
LEC6 DC24 0V Shutdown is lifted Switch Ry Stop Switch Gateway EMG + Surge suppressor Ry Unit EMG Power supply plug (1st. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (2nd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (3rd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Caution When the stop signal
Cable length (L) [m] A1 1 2 5 6 (17.7) (10.2) (14) (18) 1 3 5 8 A B C 1.5 3 5 8 A6 B1 B3 A1 A3 B6 (13.5) 1 2 (5.7) 15 16 Connector B Connector D (30.7) L (11) (14.7) (10) 8 A B C LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) 10 15 Actuator side Controller side 20 (5.5) (6.3) (5.7) (14.2) Connector C (Terminal no.)
For mounting the limit switch, order the switch mounting bracket (WRF-BK) separately. For details, refer to page 86.
LEC6 DC24 0V Shutdown is lifted Switch Ry Stop Switch Gateway EMG + Surge suppressor Ry Unit EMG Power supply plug (1st. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (2nd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (3rd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Caution When the stop signal
LEC6 DC24 0V Shutdown is lifted Switch Ry Stop Switch Gateway EMG + Surge suppressor Ry Unit EMG Power supply plug (1st. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (2nd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (3rd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Caution When the stop signal
RLS EMG Ry C 24V 24V M 24V 0V 0V (2 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V LECOFF 25 - 7CN3: 1 5 4 3 2 1 2 5 4 3 2 1 9 8 7 6 9 8 7 6 3 RXDTXD-P / 4 5 DGND 6 VP 7 8 RXD/TXD-N / 9 PRODIBUS DP 6GK1 500-0FC106ES7 972-0BA12-0XA0 PROFIBUS DP 26 - 8CN1:IF CONT 81 5 (LEC) LEC-CG1-1 LEC-CG2-1 LEC-CG2b) M12 4pin b) M12 4pin LEC-CGD
ULUL1310Class2 6.2 2) AWG20(0.5mm (24V0V) 60 2) EMG AWG20(0.5mm (EMG+,EMG-) 60 8mm 21 - D (100) D 6.3 (CN2SW)ON (EMG+,EMG-) (LEC)EMG (CN2SW) RY CN4 CN2 EMG+ EMG24V 0V (CN2SW)ON EMG+,EMG-(LEC)OFF (LEC)(EMG+,EMG-) 22 - (LEC) ()LEC6 DC24V 0V Ry EMG+ Ry EMG(1 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (2 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3 ) BK RLS EMG Ry C 24V 24V M
LEC6 DC24 0V Shutdown is lifted Switch Ry Stop Switch Gateway EMG + Surge suppressor Ry Unit EMG Power supply plug (1st. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (2nd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (3rd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Caution When the stop signal