Precautions Pull a connector out vertically, never at an angle.
Data View A-A Mounting dimensions Bore size (mm) Stroke range (mm) N M L K J I B AP AO AN AM AL AK AJ AI AH AG AB AA A 20 25 32 40 50 75, 100, 125, 150, 200 25 38 80 60 44 25 106 22 M6 110 55 9 6.6 90 75 120 105 13 11 84 32 46 95 70 52 30 120 27 M8 125 65 9 9 100 84 136 120 13 15 89 75, 100 125, 150 200, 250 300 32 50 105 80 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 38 60 125 95
45 50 25 55 65 Vertical 2 4 0.5 7.5 15 4 10 20 2 2 23 Up to 450 10 to 700 5 to 360 20 to 1100 12 to 750 6 to 400 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 850 10 to 300 451 to 500 10 to 600 5 to 300 20 to 1100 12 to 750 6 to 400 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 850 10 to 300 501 to 600 20 to 900 12 to 540 6 to 270 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 850 10
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Note) The temperature stability is as follows: ±2.0℃ for the HRSE, ±0.5℃ for the HRS090, and ±1.0℃ HRS100/150/200.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
FILTER FOR HRS100. OTHERS. HRS - NO SIZE RATING. 2.23666 lb. 21.
SV4000 20 20 stations Rc 3/8 Note 1) Double wiring specification: Single, double and 3 position solenoid valves can be used on all manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout.
ro en Size ta t r ti n r o n an e n d tio ge 95 ta 10.2 10 20 30 50 70 100 200 ro m mu 7.2 xi Ma 6.5 8.2 7.0 Note) The drawing shows the rotation range of the positioning pin hole.
Never remove valve at an angle.
19 20 19 20 19 20 19 20 19 20 19 20 19 20 1 2 3 4 5 6 7 8 9 10 1 2 3 4 NEW CONCEPT N.C. valve N.C. valve N.C. valve N.O. valve N.O. valve N.O. valve 5 6 7 8 9 10 1 2 3 4 R2 B R1 A P IP65 enclosure compliant kit (Lead wire) M 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 5 (R1) 3 (R2) 5 (R1) 3 (R2) 5 (R1) 3 (R2) 1 2 3 4 4 (A) 2 (B) 4 (A) 2 (B) 4 (A) 2 (B) IP65 enclosure compliant
Cutout window View A-A' Mounting Standard Stroke GK BP AG AB A AA AN B GD AH AI AJ AK AL AM AO AP BZ GC Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 13 11 54 75 32 28 134 150 108 140 M 8 135 110 4 9 9 104 86.5 16 15 62 88 37 29 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 16 15 62 88 37 30
Cutout window View A-A' Mounting Standard Stroke GK BP A AA AB AG AH AI AJ AK AL AM AN AO AP B BZ GC GD Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 11 13 75 32 28 54 134 150 108 140 M 8 135 110 4 9 9 104 86.5 15 16 88 37 29 62 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 15 16 88 37 30 62