Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: w/Automatic Fluid Fill Function
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: w/Automatic Fluid Fill Function
Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: Applicable to Deionized Water Piping
Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: SI Unit Only
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: SI Unit Only
Applicable model HRS-WL003 HRS090-mm-20/40 Parts List q No.
Technical Data HRS-R HRS HRS090 HRS 100/150 HRS200 HRSH090 HRSH HRSE HRR HRL HRZ HRZD HRW HECR HEC HED HEB Lots of variations are available according to the users requirements.
Note) Lead wire length symbols: 0.5 m Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z CS1 C76 C85 C95 CP95 NCM NCA D-X 20Data 6-15-7 7 Series NCA1 Basic Style: NCA1B (MX0 mounting style) ZB + Stroke P + Stroke D across flats 4-DD 2-EE (NPTF) AA KK EA MM BA B A C R WF G J E LF + Stroke Bore size (in) MM KK A AA B BA C D DD E EA EE G J R WF Y LF P ZB 150 (1.5") 5/8 7/16-20 3/
J G R CM2 WF E TL TL LF + Stroke ZB + Stroke A CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB TD0.001 0 ZB P LF Y WF TL R J G Bore size (in) MM KK A AA B C D DD E EA EE 150 (1.5") 5/8 7/16-20 3/4 2.02 1 1/8 3/8 9/16 1/4-28 2 0.3 1 4 3/4 2.36 3 5/8 1.71 1 1
3.13 4.88 3.25 1.63 6.63 800 (8") 1.375 1-14 1.63 9.10 2.000 5/8-18 8.50 3/4 NPT 5.13 3.25 6.44 4.25 1.63 6.75 MX1 Tie rod extended both ends (BA) P + Stroke BB BB AA 4-DD 2-EE KK MM B TH LF + Stroke WF TG E ZJ + Stroke A Bore Size (in) MM KK A AA B BB DD E EE LF+ P+ TG TH WF ZJ+ 500 (5") 1.000 3/4-16 1.13 5.80 1.500 1.81 1/2-20 5.50 1/2 NPT 4.50 2.88 4.10 2.75 1.38 5.88 600 (6") 1.375 1
Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) Specications Model HRS090-Al-20-l HRS090-Al-40-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.15 Control method PID control Ambient temperature1 C
MP2 Double detatchable head side clevis style (D) XD + Stroke A UB P + Stroke 2-EE MR MAX KK MM B CD (PIN) TH LR CB E WF LF + Stroke F Bore Size (in) MM KK A B CB CD E EE F LF+ LR MR P+ TH UB WF XD+ 500 (5") 1.000 3/4-16 1.13 1.500 1.280 .750 5.50 1/2 NPT .63 4.50 .94 .95 2.88 2.75 2.500 1.38 7.75 600 (6") 1.375 1-14 1.63 2.000 1.530 1.000 6.50 3/4 NPT .75 5.00 1.31 1.32 3.13 3.25 3.000 1.63
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Laser optical system Optical system CH2 Laser oscillator Oscillator Optical system CH1 Oscillator CH1 CH2 Cooling capacity [kW] Total 5, 9.5 Temperature stability [C] 0.1 0.5 Set temperature range [C] 15 to 25 CH1+0 to 15 Footprint reduced by 21% Space saving Dual thermo-chiller 1 unit Thermo-chiller 2 units Optical system Optical system Oscillator Oscillator HRLE090 HRS012 HRS090 + Reduced
Applicable model HRS-WL003 HRS090-mm-20/40 Parts List q No.
3/4-16 0.38 0.75 4.38 4.75 4.51 4.88 1.56 0.62 0.749 7/16-20 0.88 1.50 0.78 0.437 CS1 C76 Double acting, single rod Block mounting: NC(D)MR C85 C95 Z1 B + Stroke NA CP95 W YE NCM CA EA 2 holes DD tap on AA dia bolt circle B pilot A EE NPT XA NE NCA TN MM DEA E -X D across flats KK UNF 2A EE NPT 202 holes drill and cbore NH cap screw tap NT-UNC Data (in) Bore size (in) MM KK NT XA NH YE WF
TF ZB + STROKE UF BORE A E EE FB KK M R TF UF W WF ZB 40 (1.50") 0.75 2.00 1/8 0.31 7/16-20 0.16 1.43 2.75 3.38 0.63 1.00 4.62 50 (2.00") 0.75 2.50 1/4 0.37 7/16-20 0.22 1.84 3.38 4.13 0.63 1.00 5.26* 63 (2.50") 0.75 3.00 1/4 0.37 7/16-20 0.28 2.19 3.88 4.63 0.63 1.00 5.25 80 (3.25") 1.13 3.75 3/8 0.44 3/4-16 0.28 2.76 4.68 5.50 0.75 1.38 6.51* 100 (4.00") 1.13 4.50 1/2 0.44 3/4-16 0.31
of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO-CHILLER, AIR COOLED, HRS090
the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO-CHILLER, WATER COOLED, HRS090
of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO-CHILLER, AIR COOLED, HRS090