An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Thermistor Sensor for HRL300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 12 lb
Accessories Set (Option N), HRL-***-A-20, HRS090 AND LARGER CAPACITIES, O88, 6 lb
Noise Filter for HRL200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 1.1 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Thermistor Sensor HRL100/200/300-A-20/40, HRS090 AND LARGER CAPACITIES, O88, 10 lb
DI Sensor for HRL100/200/300-A*-20/40, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J (w/Automatic Fluid Fill Function)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: W (SI Unit Only)