Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping
Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: w/ Earth Leakage Breaker + w/ Automatic Fluid Fill Function + Applicable to Deionized Water Piping
Cooling Capacity: Cooling Capacity: 2600/3200W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J + M
Cooling Capacity: Cooling Capacity: 4700/5100W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J + M
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J + M
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B + J + M
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: J (Automatic Water Supply Function)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJ (B + J)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)