Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping
Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 040 (Cooling Capacity: 3800W/4200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024
1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024
, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024
1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024
Prepare an earth leakage breaker with a capacity of 10 A as listed in the HRS024 catalog. Set the current sensitivity of the earth leakage breaker to 30 mA.
grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Condenser Bracket for HRS024
with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Comm D-Sub for HRS024
10.5 40 41 46 20 77 90 102 115 140 12.5 25 37.5 50 75 181 194 206 219 244 27 10.5 Symbol Stroke (mm) With Air Cushion Boss-cut Female Rod End (mm) (mm) Bore size A1 H MM ZZ 20 8 20 M4 x 0.7 95 25 8 20 M5 x 0.8 95 32 12 20 M6 x 1 97 40 13 21 M8 x 1.25 125 Bore size WA 20 13 25 13 32 13 40 16 Bore size ZZ Without With rod boot 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 20 103 130 143
S + Stroke H ZZ + l + Stroke ZZ + Stroke MB1 CA2 CS1 Stroke range (mm) A Bore size (mm) B C AL B1 D E F G H1 J KA M MM With rod boot Without rod boot C76 40 50 63 20 to 500 up to 500 30 27 60 22 44 16 32 10 15 M8 x 1.25 14 11 M14 x 1.5 8 20 to 600 up to 600 35 32 70 27 52 20 40 10 17 M8 x 1.25 18 11 M18 x 1.5 11 C85 20 to 600 up to 600 35 32 85 27 64 20 40 10 17 M10 x 1.25 18 14 M18 x 1.5
40 7.5 7 6 Deptt 6 5 1 2 5 15.5 78.5 29 5 M4 x 0.7 6 M O x I O I 20 5.5 I 46 I 9.5 Deptf 8 '13.519.5 89 tlictD!