SMC Corporation of America
Elite Part Number Search
Search Results "CY1SG40-600Z-A93VL"

This is a legacy product, and replaced byCY1SG15-350BZ-A93VL, CYL, RODLESS, SLIDER, AUTO-SW, ACTUATOR, 15MM CY2S DBL-ACT AUTO-SW, 3.02936 lb

This is a legacy product, and replaced byCY1SG25-410BZ-A93VL, CYL, RODLESS, SLIDER, SW CAP, ACTUATOR, CY1S GUIDED CYLINDER, IM, 25MM CY1S SLIDE BEARING, 9.03895 lb

This is a legacy product, and replaced byCY1SG40-560BSZ-A93VL, CYL, RODLESS, SLIDER, AUTO-SW, ACTUATOR, CY2S GUIDED CYLINDER, ME, 40MM CY2S DBL-ACT AUTO-SW, .00000 lb

Piping: G (Centralized Piping Type), Bore Size: 32mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 600mm, Stopper Type: Bumper Bolt (Resin Tipped), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)

Piping: G (Centralized Piping Type), Bore Size: 25mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 600mm, Stopper Type: Bumper Bolt (Resin Tipped), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)

Piping: Centralized Piping Type, Bore Size: 25mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 600mm, Stopper Type: Bumper Bolt (Resin Tipped), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Piping: Centralized Piping Type, Bore Size: 32mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 600mm, Stopper Type: Bumper Bolt (Resin Tipped), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

This is a legacy product, and replaced byCDG1BA40-600Z-XC6, BASE CYLINDER, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, MC, 40MM CG OTHERS (COMBO), 4.9163 lb

This is a legacy product, and replaced byMY1B32TN-600Z, CYL, RODLESS, MECH JOINT, ACTUATOR, MY1B GUIDED CYLINDER, LE, 32MM MY1B DBL-ACT AUTO-SW, 6.13925 lb

This is a legacy product, and replaced byMY1B25-600Z, CYL, RODLESS, MECH JOINT, ACTUATOR, MY1B GUIDED CYLINDER, IE, 25MM MY1B DBL-ACT AUTO-SW, 5.91941 lb

This is a legacy product, and replaced byCG1DN40-600Z, 40MM CG DOUBLE-ACTING, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, MD, 40MM CG DOUBLE-ACTING, 5.51155 lb

This is a legacy product, and replaced byCDG1DA40-600Z-C73L, CYL, AIR, DBL ACT, AUTO-SW, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, ME, 40MM CG DBL-ACT AUTO-SW, 5.87899 lb

This is a legacy product, and replaced byCDA2C50TN-600Z, CYL, TIE ROD, NON LUBE,AUTO-SW, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, NE, 50MM CA1 DBL-ACT AUTO-SW, 5.60841 lb

This is a legacy product, and replaced byCM2YB20-600Z, CYL, RND BODY, LOW FRICTION, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, HC, 20MM CM2 OTHERS (COMBO), .82714 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CM2Air cylinderCM2Double acting, Single rod--666

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A93VL

Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A93VL

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,