SMC Corporation of America
Elite Part Number Search
Search Results "CY1SG10-150BZ-M9BWL"

Piping: G (Centralized Piping Type), Bore Size: 20mm, Port Thread: TN (NPT), Stroke: 150mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Piping: G (Centralized Piping Type), Bore Size: 25mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 150mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Piping: Centralized Piping Type, Bore Size: 25mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 150mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Piping: Centralized Piping Type, Bore Size: 40mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 150mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Piping: Centralized Piping Type, Bore Size: 20mm, Port Thread: NPT, Stroke: 150mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 150, Max. Load Mass (Horizontal Mounting)(kg): 20~39.9, Table Size Length L(mm): 70, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Sliding Guide] Guide Type of Slide Bearing, Table Size Width W(mm): 99, Table Size Height H(mm): 54, Table Surface Treatment: No, Environment: General

Piping: G (Centralized Piping Type), Bore Size: 10mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 100mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Piping: G (Centralized Piping Type), Bore Size: 10mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 200mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Piping: G (Centralized Piping Type), Bore Size: 10mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 50mm, Stopper Type: Bumper Bolt (Resin Tipped), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Piping: Centralized Piping Type, Bore Size: 10mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 100mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Piping: Centralized Piping Type, Bore Size: 10mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 200mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Piping: Centralized Piping Type, Bore Size: 10mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 50mm, Stopper Type: Bumper Bolt (Resin Tipped), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 20, Stroke(mm): 150, Max. Load Mass (Horizontal Mounting)(kg): 10~19, Table Size Length L(mm): 70, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Sliding Guide] Guide Type of Slide Bearing, Table Size Width W(mm): 90, Table Size Height H(mm): 46, Table Surface Treatment: No, Environment: General

Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 40, Stroke(mm): 150, Max. Load Mass (Horizontal Mounting)(kg): 40~57, Table Size Length L(mm): 95, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Sliding Guide] Guide Type of Slide Bearing, Table Size Width W(mm): 142, Table Size Height H(mm): 76, Table Surface Treatment: No, Environment: General

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, CY1S GUIDED CYLINDER, EM, 10MM CY1S SLIDE BEARING, 7.33955 lb

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,