SMC Corporation of America
Elite Part Number Search
Search Results "CHDSDFZ40-300A-B-M9BA"

Hs Ht A B Hs A B Hs A B Hs Ht B D-P4DW D-M9 D-M9W D-M9A 12 D-A9 Hs D-B54 Note) The above drawing is the switch band mounting example for the D-P4DWS.

U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.

Round plate (Including column) Position of rotational axis: Through the center (A) Number of axis teeth =a (B) 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth =b 5.

In the case of mounting auto switch from B direction Step 2) Insert the auto switch into the auto switch installation groove from direction B. A B MHZ MHF Step 3) Slide the auto switch in the direction of the arrow until the indicator light illuminates.

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/

B 0.2 A 0.2 Bore size [mm] A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 7.

When auto switches D-M9/M9W/Y59 D-M9A D-Y7, Y7W are used A B L Auto Switch Hysteresis MHZ When auto switches D-M9V/M9WV/Y69 D-M9AV D-Y7V, Y7WV are used Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc. MHF A B MHL L MHR MHK MHS Max.

(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting), Made to Order Option: XC3 (Special Port Location), Rod Port Location (from Rod Side): B, Head Port Location (from Rod Side): B

Magnet: D (Built-in Magnet), Series: A2 (Standard), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 40mm, Port Thread: Rc, Stroke A: 200mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: None, +: None, Stroke B: None, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: M9BA--Solid State, Water Resist

Magnet: D (Built-in), Model: E (Aluminum Alloy, 3.5MPa), Mounting: B (Basic), Bore Size: 80mm, Rod Dimension: B (Series B Rod Size), Stroke: 200mm, Rod End Nut: A (w/Rod End Nut), Rod Boot: J (Nylon Tarpaulin), Cushion: R (Front Cushion), Port Location: D (Port: Top/Cushion Valve: Left), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m

Magnet: D (Built-in), Model: E (Aluminum Alloy, 3.5MPa), Mounting: B (Basic), Bore Size: 40mm, Rod Dimension: B (Series B Rod Size), Stroke: 300mm, Rod End Nut: None, Rod Boot: None, Cushion: w/Double Side Cushion, Port Location: Port: Top/Cushion Valve: Right, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal

Magnet: Built-in Magnet, Series: Standard, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 40mm, Port Thread: Rc, Stroke A: 75mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: None, +: +, Stroke B: 125mm, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal

Magnet: Built-in Magnet, Series: Standard, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 40mm, Port Thread: Rc, Stroke A: 200mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: None, +: None, Stroke B: None, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire

Magnet: Built-in, Mounting: Detachable Rear Clevis, Bore Size: 2", Stroke A: 1", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 4 pcs., Dual, Tandem Option: Dual Op., Sgl. Rod

Magnet: Built-in, Mounting: Head trunnion, Bore Size: 4", Stroke A: 4", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1", Cushion B: None, Rod Boot B: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl.

Magnet: With Magnet, Mounting: Front Rectangular Flange Type, Bore Size: 63mm, Port Thread Type: NPT, Stroke: 300mm, Rod End Nut: With Rod End Nut, Cushion: With Cushion in Both Sides, Port Position: Port on Top - Cushion Valve Down, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Magnet: D (With Magnet), Mounting: FY (Front Rectangular Flange Type), Bore Size: 63mm, Port Thread Type: TN (NPT), Stroke: 300mm, Rod End Nut: A (With Rod End Nut), Cushion: With Cushion in Both Sides, Port Position: B (Port on Top - Cushion Valve Down), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch