SMC Corporation of America
Elite Part Number Search
Search Results "CHDKDB20-30M-M9BVL"

W hen a current of 30m AD C or m ore i s appl i ed, t he over current ci rcui t i s archi ved, Er. 5 i s di spl ayed and t he operat i on st ops.

W hen a current of 30m AD C or m ore i s appl i ed, t he over current ci rcui t i s archi ved, Er. 5 i s di spl ayed and t he operat i on st ops.

Use screws that are between the maximum and minimum screw-in depths in length. 5 Secure the motor cable and lock cable so that the cables are not repeatedly bent. 24 Lock cable 20 15 Dimensions [mm] Model L C D E F G H J LES25LEm-30m-m 144.5 4 48 133.5 105 2 46 46 LES25LEm-50mm-m 170.5 6 42 159.5 131 2 84 84 LES25LEm-75mm-m 204.5 6 55 193.5 165 2 112 112 LES25LEm-100mm-m 277.5 8 50 266.5

The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion

Magnet: D (Built-in Magnet), Mounting: B [Through Hole (Standard)], Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 30mm, Body Option: M (Rod End Male Thread), Auto Switch: M9BV--Solid State , Gen. Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m)

Built-in Magnet: D (With Magnet), Mounting Style: C (Single Clevis), Bore Size: 40mm, Stroke: 30mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

If this product is connected using power cables that are more than 30m long or go outside of a building then external protection devices should be added to protect against electrical surge damage.

Vibration resistance allows for normal operation of up to 30m/s2 (45 to 250Hz). Be advised that continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibration or impacts. 5 XL-OMS0001-B High temperature type (temperature specification / H0 H4 H5) 1.

: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4. 2 XL-OMY0001 / 1 1.5 *3) 3)1 1 () 3 XL-OMY0001 1 &/ 1.52 2 ( ) 5 5 P-01-11 P-06-3 4 XL-OMY0001 2.2 A6063 SUS316L SUS304 5 P11 FKM 3 3[]P8 60 , 245250Hz 30m

Vibration resistance allows for normal operation of up to 30m/s2 (45 to 250Hz). Be advised that continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibration or impacts. 5 XL-OMV0007 High temperature type (temperature specification / H0 H4 H5) 1.

Vibration resistance allows for normal operation of up to 30m/s2 (45 to 250Hz). Be advised that continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibration or impacts. 5 XL-OMV0017 High temperature type (temperature specification / H0 H4 H5) 1.

machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 2 XL-OMV0002 1. 2. 3. 4., / 1 1.5 *3) *3)1 1 () 3 XL-OMV0002 1.1 A6063SUS316LSUS304 FKM XLC-80,XLC-100,XLC-160 :Y-VAC2 60 XLC-16,XLC-25,XLC-40 0.3MPa0.5MPa XLC-50,XLC-63,XLC-80,XLC-100,XLC-160 0.4MPa0.5MPa 245250Hz 30m

60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4. 2 XL-OMY0002 / 1 1.5 *3) 3)1 1 () 3 XL-OMY0002 1 &/ 1.52 2 ( ) 5 5 P-01-11 P-06-3 4 XL-OMY0002 2.2 A6063SUS316LSUS304 5 P11 FKM 3 3[]P8 60 , 245250Hz 30m

Vibration resistance allows for normal operation of up to 30m/s2 (45 to 250Hz). Be advised that continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibration or impacts. High temperature type (temperature specification /H4 H5) 1.

A6063SUS316LSUS304 FKM 245250Hz 30m/s /H4 H5 , 510% 4 XL-OMY0003 O 0.1mm0.2mm O 5 P9 O 6 P10 P13 5 XL-OMY0003 2.2 16 25 40 50 (5150) XLH16-30-1 XLH25-30-1 XLH40-30-1 XLH50-30-1 1FKM:No.1349-80 XLH16-30-1-XN1 / 16 25 40 50 AS568-025V AS568-030V AS568-035V AS568-039V AS568-025 ** AS568-030 ** AS568-035 ** AS568-039 ** B2401-V15V B2401-V24V B2401-P42V AS568-227V B2401-V15

Table 6-9 Rating Soldering terminal Rated voltage Resistance load 250 VAC 5A (3) Other performance Table 6-10 Other specifications Item Specifications Insulation resistance 100 M or more (Measured by 500 VDC, insulation resistance tester. ) Contact resistance 30m or less Between terminals with the same pole AC1000V 50/60Hz 1min Between charged metal part and ground AC1500V 50/60Hz 1min Withstand