L (Example) A93L 5m . Z (Example) F9NWZ Solid state auto switches marked "" are produced upon receipt of order.
Fittings & Tubing Air Cylinders Rotary Actuators 4.5 8 11-MXJ4 Model 11-MXJ6 11-MXJ8 6 M3 x 0.5 Air Double acting 0.15 to 0.7 MPa 1.05 MPa 10 to 60C Bore size (mm) Piping port size Fluid Action Operating pressure Proof pressure Ambient and fluid temperature Suction flow rate L/min (ANR) Size 4 6 8 1 1 1 Operating speed range (Average operating speed) Note) 50 to 500 mm/s (Metal stopper: 50
This is a legacy product, and replaced byNCDRA1BS50-90CZ-A93L NCRA ROTARY ACTUATOR. NCRA 50 SGL/DBL ROD W/AUTO-SW. ACTUATOR. 50MM NCRA DBL-ACT AUTO-SW. 3.30000 lb. NE.
Cylinder stroke (mm) Nil C M Standard strokes (mm) 5, 10, 15, 20, 25, 30 Bore sizes (mm) Action 12, 16 D Double acting 20 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Auto switch specifications Manufacturing intermediate strokes Intermediate strokes can be manufactured in 1mm increments by installing spacers in a standard stroke cylinder.
Mounting: L (Axial Foot), Bore Size: 12mm equiv., Stroke: 50mm
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: Without
Mounting: L (Axial Foot), Bore Size: 12mm equiv., Stroke: 100mm, Connector: Z (w/o Connector), Sensor Cable Length: L (3m), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Mounting: L (Axial Foot), Bore Size: 12mm equiv., Stroke: 75mm, Connector: Z (w/o Connector), Sensor Cable Length: L (3m), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Mounting: Axial Foot, Bore Size: 12mm equiv., Stroke: 100mm, Connector: w/o Connector, Sensor Cable Length: 3m, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Mounting: Axial Foot, Bore Size: 12mm equiv., Stroke: 75mm, Connector: w/o Connector, Sensor Cable Length: 3m, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Mounting: L (Axial Foot), Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire
Mounting: L (Axial Foot), Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Mounting: L (Axial Foot), Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)
Mounting: L (Axial Foot), Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Mounting: Axial Foot, Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BW,
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BW,
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead