Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 20mm equiv., Stroke: 75mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 20mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 20mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Mounting: Direct Mount Rod Side Tapped, Bore Size: 20mm equiv., Stroke: 75mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Mounting: Direct Mount Rod Side Tapped, Bore Size: 20mm equiv., Stroke: 75mm, Connector: w/Connector, Sensor Cable Length: 3m, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Mounting: Direct Mount Rod Side Tapped, Bore Size: 20mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 0.5m, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: M9BA, Lead
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: M9BA, Lead
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: M9BA, Lead
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: M9BA, Lead
Then, the charging time (T) for a 100l tank, With the pressure increase ratio from 2 to 3, the time of 17060=110 sec.(t) is given for 10l tank by the graph. Then, the charging time (T) for a 100l tank, With the pressure increase ratio from 1.6 to 2.0, the time of 3.51.1=2.4 sec.(t) is given for 10l tank by the graph.
Use 0.75kW per 100l/min of air consumption as a guide for the relationship of the air consumption to the compressor.
Use 0.75kW per 100l/min of air consumption as a guide for the relationship of the air consumption to the compressor.
Use 0.75kW per 100l/min of air consumption as a guide for the relationship of the air consumption to the compressor.
Item Display Content Setting of connection product [4L] 4 L range [16L] 16 L range [40L] 40 L range [PFW] is selected [100L] 100 L range [250L] 250 L range [10L] 10 L range [rAnG] [50L] 50 L range Selection of flow range [100L] 100 L range [PFA] is selected [200L] 200 L range [500L] 500 L range [4L] 4 L range [PFd] is selected [16L] 16 L range [40L] 40 L range Press the SET button to set.
Cylinder model Hexagon wrench key MKB12-10Z -20Z -30Z MKB16-10Z -20Z -30Z MKB20-10Z -20Z -30Z MKB25-10Z -20Z -30Z MKB32-10Z -20Z -30Z -50Z MKB40-10Z -20Z -30Z -50Z MKB50-10Z -20Z -30Z -50Z MKB63-10Z -20Z -30Z -50Z CQ-M3 x 50L x 60L x 70L CQ-M3 x 50L x 60L x 70L CQ-M5 x 75L x 85L x 95L CQ-M5 x 75L x 85L x 95L CQ-M5 x 85L x 95L x 105L x 125L CQ-M5 x 80L x 90L x 100L x 120L CQ-M6 x 90L x 100L
10 Applicable Products Applicable Products Material restriction: 90series Material restriction + Lub-retainer: 91series Material restriction + Lub-retainer + Heavy-duty scraper: 91--XC4 series Material restriction + Vacuum port for vacuum suction: 92series Air Preparation Equipment : Available as standard Remarks Description Series 90With fittings for purge air discharge IDG50L to 100L
less Switch Table specification Grease for dust seal application With dust seal Fluorine grease for vacuum equipment made by NOK Kluber Traveling distance of 4000km, 4 million reciprocations, or operation period of 6 months, whichever comes first Grease maintenance schedule Rc 1/4, one each on both axial surfaces Seal the unused port with a plug, suction at both ends Vacuum suction port 100l
Suction at both ends. 50l/min (ANR) 100l/min (ANR) Suction flow rate For basic specifications such as allowable moment, refer to the "Standard motor" pages for equivalent products listed on Features pages 1 and 2. 106 Made to Order/Clean Room Specification Series LJ1H20 Dimensions/LJ1H202 (X60) Scale: 15% When two dimensions are shown, the top dimension is for 100 to 600mm strokes, and the
less Switch Table specification Grease for dust seal application With dust seal Fluorine grease for vacuum equipment made by NOK Kluber Traveling distance of 4000km, 4 million reciprocations, or operation period of 6 months, whichever comes first Grease maintenance schedule Rc 1/4, one each on both axial surfaces Seal the unused port with a plug, suction at both ends Vacuum suction port 100l